Data Sheet
90W AC-DC High Reliability Medical Adaptor
GSM90A ser ie s
SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE Note.2
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
RIPPLE & NOISE (max.) Note.3
OUTPUT
VOLTAGE RANGE Note.7
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
ENVIRONMENT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT(max.)
SAFETY STANDARDS
SAFETY &
EMC
(Note. 8)
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
PROTECTION
GSM90A15-P1MGSM90A12-P1M GSM90A19-P1M GSM90A24-P1M GSM90A48-P1M
15V12V
GSM90A15GSM90A12
19V
GSM90A19
24V
GSM90A24
48V
GSM90A48
150mVp-p120mVp-p 180mVp-p 200mVp-p 240mVp-p
VOLTAGE TOLERANCE Note.4
LINE REGULATION Note.5
LOAD REGULATION
±5.0%±5.0% ±4.0% ±3.0% ±2.5%
±1.0%±1.0% ±1.0% ±1.0% ±1.0%
±5.0%±5.0% ±4.0% ±3.0% ±2.5%
80 ~ 264VAC
47 ~ 63Hz
PF>0.91 / 230VAC PF>0.95 / 115VAC at full load
89%88% 89% 90% 91%
1.3A / 115VAC 0.6A / 230VAC
30A / 115VAC 65A / 230VAC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:SHORT
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
405.6K hrs min. MIL-HDBK-217F(25℃)
-30 ~ +70℃ (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-40 ~ +85℃, 10 ~ 95% RH
±0.03% / ℃ (0~40℃)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
145*60*32mm (L*W*H)
0.45Kg; 30pcs/14.5Kg/1CUFT
CONNECTOR
PLUG
CABLE
See page 3 ; Other type available by customer requested
See page 3 ; Other type available by customer requested
℃
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, EN61204-3 medical level, criteria A
Compliance to EN55011 (CISPR11) Class B, EN61000-3-2,-3, FCC PART 15 class B
OVERLOAD
OVER VOLTAGE
110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
6A6.67A 4.74A 3.75A 1.87A
0 ~ 6A0 ~ 6.67A 0 ~ 4.74A 0 ~ 3.75A
0 ~ 1.87A
90W80W 90W 90W 90W
Protection type : Shut down o/p voltage, re-power on to recover
ANSI/AAMI ES60601-1, TUV EN60601-1 approved
SETUP, RISE TIME Note.6
HOLD UP TIME (Typ.)
1000ms, 50ms / 230VAC 1000ms, 50ms / 115VAC at full load
20ms / 230VAC 20ms / 115VAC at full load
OVER TEMPERATURE
Shut down o/p voltage, re-power on to recover
EMC IMMUNITY
EMC EMISSION
Earth leakage current < 100 A/264VAC , Touch current <100 A/264VAC
μ μ
ISOLATION LEVEL
Primary-Secondary: 2xMOPP
File Name:GSM90A-SPEC 2016-10-31