Data Sheet
SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
Note.2
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
RIPPLE & NOISE (max.)
Note.3
OUTPUT
SETUP, RISE, HOLD UP TIME
VOLTAGE RANGE
Note.7
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INPUT
INRUSH CURRENT (max.)
VOLTAGE TOLERANCE
Note.4
LINE REGULATION Note.5
LOAD REGULATION Note.6
LEAKAGE CURRENT(max.)
OVERLOAD
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
ISOLATION LEVEL
ENVIRONMENT
WORKING TEMP.
WORKING HUMIDITY
TEMP. COEFFICIENT
VIBRATION
PROTECTION
OVER VOLTAGE
SAFETY STANDARDS
STORAGE TEMP., HUMIDITY
LIFE
MTBF
DIMENSION
PACKING
I/P-O/P:5656VDC
3 years : 100% load 40 , 8hours / day℃
400Khrs min. MIL-HDBK-217F(25 )℃
75.5*39.1*56.2mm (L*W*H)
200g ; 60pcs / 13kg / CARTON
PLUG
CABLE
Pimary - Secondary: 2 x MOPP
Parameter
Parameter
ESD
EMC IMMUNITY
EMC EMISSION
EN55011, EN60601-1-2
RF field susceptibility
EFT bursts
Surge susceptibility
Conducted susceptibility
Magnetic field immunity
Voltage dip, interruption
Conducted emission
Radiated emission
Harmonic current
Voltage flicker
1.5A / 115VAC 0.8A / 230VAC
-30 ~ +70 (Refer to "Derating Curve")℃
20% ~ 90% RH non-condensing
±℃℃0.03% / (0 ~ 40 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
105 ~ 160% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
110 ~ 140% rated output voltage
Touch current < 100 A/264VAC
μ
SAFETY &
EMC
(Note. 8)
OTHERS
NOTE
TUV EN60601-1/EN60601-1-11,ANSI/ AAMI ES60601-1/ES60601-1-11(3.1 version), CAN/CSA-C22 3 edition, approved
rd
EAC TP TC 004
CONNECTOR
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. ℃
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1 f & 47 f capacitor. μμ
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 10% to 100% rated load.
7.Derating may be needed under low input voltage. Please check the derating curve for more details.
8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
50A / 115VAC 100A / 230VACCold start
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH℃
See page 4 5 ; other type available by customer requested~
See page 4 5 ; other type available by customer requested~
Standard
Standard
EN61000-3-2
EN61000-3-3
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
EN61000-4-11
Test Level / Note
Test Level / Note
Class B
Class B
Class A
-----
Level 4, 15KV air ; Level 4, 8KV contact
Level 3, 2KV/Line-Line
Level 4, 30A/m
Level 3, Line-Line2KV ,1KV ineterconnect Lines at 100KHz rate
Level 2, 3V
Level 3, 10V/m(80MHz~2.7GHz)
Table 9, 9~28V/m(385MHz~6GHz)
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
EN55011 (CISPR11
),FCC PART 18
EN55011 (CISPR11
),FCC PART 18
80 ~ 264VAC 113 ~ 370VDC
47 ~ 63Hz
-30 ~ +85 , 10 ~ 95% RH non-condensing℃
Protection type : Clamp by zener diode, output short
500ms, 30ms, 10ms/230VAC 500ms, 30ms, 10ms/115VAC at full load
5V 9V7.5V 12V 15V 18V 24V 48V
GEM60 05I GEM60 09IGEM60 07I GEM60 12I GEM60 15I GEM60 18I GEM60 24I GEM60 48I
GEM60 05-P1JI GEM60 07-P1JI GEM60 09-P1JI GEM60 12-P1JI GEM60 15-P1JI GEM60 18-P1JI GEM60 24-P1JI GEM60 48-P1JI
6A 5.5A6A 4.5A 4A 3.33A 2.5A 1.25A
0 ~ 6A 0 ~ 5.5A0 ~ 6A
0 ~ 4.5A
0 ~ 4A 0 ~ 3.33A 0 ~ 2.5A
100mVp-p 100mVp-p100mVp-p 100mVp-p 120mVp-p 120mVp-p 120mVp-p 150mVp-p
±5.0% ±5.0%±5.0% ±5.0% ±5.0% ±3.0% ±3.0% ±3.0%
±1.0% ±1.0%±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
±5.0% ±5.0%±5.0% ±3.0% ±3.0% ±2.0% ±2.0% ±2.0%
30W 49.5W45W 54W 60W 60W 60W 60W
0 ~ 1.25A
80% 87%85% 88% 88% 88% 88% 90%
Interchangeable AC plug Specifically for GEM12I/18I/30I/40I/60I
GEM60 seriesI
60WAC-DC Reliable Green Interchangeable MedicalAdaptor
TYPE
ORDER NO.
Australian type U.K type European type US type Mix four type
AC plug-AU2 AC plug-UK2 AC plug-EU2 AC plug-US2 AC plug-MIX2
PUSH
OPEN
LOCK
PUSH
OPEN
LOCK
PUSH
OPEN
LOCK
LOCK
OPEN
LOCK
PUSH
OPEN
PUSH
PUSH
OPEN
LOCK
PUSH
OPEN
LOCK
PUSH
OPEN
LOCK
LOCK
OPEN
LOCK
PUSH
OPEN
PUSH
File Name:GEM60 -SPECI 2018-08-07