Datasheet

Interchangeable AC plug specifically for GE series
SPECIFICATION
GE40 series
40WAC-DC Interchangeable Industrial Adaptor
TYPE
ORDER NO.
Note: Please be aware that Australian type AC plug of GE40 Series CANNOT be used on GE12-GE30 series. However, UK, European, and US typeAC plug doesn't have such concern.
Order NO. of Mix four type to GE40 is AC plug-MIX3, please DO NOT orderAC plug-MIX.
U.K type European type US type
Mix four type
AC plug-UK
(for GE12/18/24/30/40)
AC plug-EU
(for GE12/18/24/30/40)
AC plug-US
(for GE12/18/24/30/40)
AC plug-MIX3
(for GE40 only)
GE40 05-P1J GE40 12-P1JGE40 09-P1JGE40 07-P1J GE40 15-P1J GE40 18-P1J GE40 24-P1J GE40 36-P1J GE40 48-P1J
IIII IIIII
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
POWER SUPPLY MAIN BODY ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE
Note.2
RATED CURRENT
OUTPUT
SETUP, RISE, HOLD UP TIME
VOLTAGE RANGE
Note.7
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INPUT
INRUSH CURRENT (max.)
LEAKAGE CURRENT (max.)
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
LIFE
DIMENSION
OTHERS
DC OUTPUT
NOTE
PLUG
CABLE
OVERLOAD
OVER VOLTAGE
12V9V7.5V5V 15V 18V 24V 36V 48V
3.3A3.3A2.66A4A 2.7A 2.2A 1.67A 1.11A 0.83A
CURRENT RANGE
0 ~ 3.3A0 ~ 3.3A0 ~ 2.66A0 ~ 4A 0 ~ 2.7A 0 ~ 2.2A 0 ~ 1.67A 0 ~ 1.11A 0 ~ 0.83A
RIPPLE & NOISE (max.)
Note.3
120mVp-p100mVp-p100mVp-p100mVp-p 150mVp-p 180mVp-p 240mVp-p 300mVp-p 300mVp-p
VOLTAGE TOLERANCE
Note.4
LINE REGULATION Note.5
LOAD REGULATION Note.6
±3.0% ±3.0% ±3.0% ±3.0%
±1.0%±1.0%±1.0%±1.0% ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
±3.0%±3.0%±3.0%±3.0%
±3.0%±3.0%±3.0%±3.0%
±3.0%
±3.0% ±3.0% ±3.0% ±3.0% ±3.0%
3000ms, 40ms, 12ms / 230VAC 3000ms, 40ms, 12ms / 115VAC at full load
90 ~ 264VAC 135 ~ 370VDC
47 ~ 63Hz
1A / 100VAC 0.5A / 230VAC
COLD START 35A / 100VAC 70A / 230VAC
0.25mA / 240VAC
110% ~ 200% rated output power
115% ~ 135% rated output voltage
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
100Khrs min. MIL-HDBK-217F (25 )
2 years : 100% load 40 , 8 hours / day
-30 ~ +70 (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-20 ~ +85 , 10 ~ 95% RH
±℃0.03% / (0 ~ 40 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
94*48.4*40mm (L*W*H)
CONNECTOR
RATED POWER (max.)
39.6W29.7W20W20W 40.5W 39.6W 40W 40W 40W
See page 4~5 ; Other type available by customer requested
See page 4~5 ; Other type available by customer requested
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Clamp by zener diode
ENVIRONMENT
PROTECTION
UL62368-1, CSA C22.2, TUV EN62368-1, AS/NZS 60950.1, CCC GB4943.1, approvedEAC TP TC 004
I/P-O/P:4242VDC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
PACKING
200g ; 50pcs / 12kg / CARTON
87%86%85%81% 87%
88% 88% 89% 89%
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 10% to 100% rated load
7.Derating may be needed under low input voltage. Please check the derating curve for more details.
8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
9.Main body unit and AC inlet plug should be ordered separately ; it needs to be used along with any of the AC inlet plug.
10.Please be aware that Australian type AC plug of GE40 Series CANNOT be used on GE12-GE30 series. However, UK, European, and US type AC plug
doesn't have such concern. Order no. of Mix four type to GE40 is AC plug-MIX3, please DO NOT order AC plug-MIX.
SAFETY &
EMC
(Note. 8)
IIII IIIII
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
GE40 12GE40 09GE40 07GE40 05 GE40 15 GE40 18 GE40 24 GE40 36 GE40 48
EMC IMMUNITY
EMC EMISSION
Parameter
Standard
EN55032
(CISPR32)
EN61000-3-2
Test Level / Note
Class B
-------
EN61000-3-3
Class B
Class A
Parameter
ESD
Standard
EN61000-4-2
Test Level /Note
EN61000-4-3
EN61000-4-4
EN61000-4-6
EN61000-4-5
EN61000-4-8
EN61000-4-11
EN55032
(CISPR32)
>.95% dip 0 5 periods, 30% dip 25 periods,
95% interruptions 250 periods
Conducted emission
Radiated emission
Harmonic current
Voltage flicker
EFT bursts
Surge susceptibility
Level 3, 8KV air; Level 2, 4KV contact
Conducted susceptibility
Level 2, 3V/m
Level 3, 1KV/L-N
Level 1, 1A/m
Level 2, 3V
Level 2, 1KV
RF field
susceptibility
Magnetic field
immunity
Voltage dips , interruption
Australian type
AC plug-AU3
(for GE40 only)
File Name:GE40-SPEC 2019-08-06