Datasheet
SPECIFICATION
GE30 seriesI
File Name:GE30I-SPEC 2022-04-15
30W AC-DC Interchangeable Industrial Adaptor
TYPE
ORDER NO.
Australian type
U.K type
European type
US type
Mix four type
AC plug-AU
AC plug-UK
AC plug-EU
AC plug-US
AC plug-MIX
GE30 12-P1J
GE30 15-P1J
GE30 18-P1J
GE30 24-P1J
I
I
I
I
I
I
I
I
I
I
I
I
POWER SUPPLY MAIN BODY ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE Note.2
RATED CURRENT
OUTPUT
SETUP, RISE, HOLD UP TIME
VOLTAGE RANGE Note.7
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INPUT
INRUSH CURRENT (max.)
LEAKAGE CURRENT (max.)
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
LIFE
DIMENSION
OTHERS
DC OUTPUT
PLUG
CABLE
OVERLOAD
OVER VOLTAGE
12V
15V
18V
24V
2.5A
2A
1.66A
1.25A
CURRENT RANGE
0 ~ 2.5A
0 ~ 2A
0 ~ 1.66A
0 ~ 1.25A
RIPPLE & NOISE (max.) Note.3
120mVp-p
150mVp-p
180mVp-p
240mVp-p
VOLTAGE TOLERANCE Note.4
LINE REGULATION Note.5
LOAD REGULATION Note.6
±3.0%
±3.0%
±1.0%
±1.0%
±1.0%
±1.0%
±3.0%
±3.0%
±3.0%
±3.0%
±3.0%
±3.0%
4000ms, 100ms, 30ms / 230VAC 4000ms, 100ms, 10ms / 115VAC at full load
90 ~ 264VAC 135 ~ 370VDC
47 ~ 63Hz
0.7A / 100VAC 0.4A / 230VAC
COLD START 40A / 100VAC 80A / 230VAC
0.25mA / 240VAC
110% ~ 200% rated output power
115% ~ 135% rated output voltage
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
100Khrs min. MIL-HDBK-217F (25℃)
2 years : 100% load 30℃, 8 hours / day
-10 ~ +50℃ (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-20 ~ +85℃, 10 ~ 95% RH
±0.03% / ℃ (0 ~ 30℃)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
81*43*40.5mm (L*W*H)
CONNECTOR
RATED POWER (max.)
30W
30W
30W
30W
See page 4~5 ; Other type available by customer requested
See page 4~5 ; Other type available by customer requested
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Clamp by zener diode
ENVIRONMENT
PROTECTION
UL62368-1, CSA C22.2 , TUV BS EN/EN62368-1, AS/NZS 60950.1, CCC GB4943, EAC TP TC 004 approved NO. 62368-1
I/P-O/P:4242VDC
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
PACKING
134g ; 50pcs / 8.4kg / CARTON
84%
86%
87%
87%
℃
http://www.meanwell.com)
※: https://www.meanwell.com/serviceDisclaimer.aspx
I I I I
I
I
I
I
I
I
I
I
GE30 12 GE30 15 GE30 18 GE30 24
SAFETY &
EMC
(Note. 8)
EMC IMMUNITY
EMC EMISSION
Parameter
Standard
BS EN/EN55032(CISPR32)
Test Level / Note
Class B
Class B
Parameter
ESD
Standard
BS EN/EN61000-4-2
Test Level /Note
BS EN/EN61000-4-3
BS EN/EN61000-4-4
BS EN/EN61000-4-6
BS EN/EN61000-4-5
BS EN/EN61000-4-8
BS EN/EN61000-4-11
BS EN/EN55032(CISPR32)
>95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
Conducted emission
Radiated emission
EFT bursts
Surge susceptibility
Level 3, 8KV air; Level 2, 4KV contact
Conducted susceptibility
Level 2, 3V/m
Level 3, 1KV/L-N
Level 1, 1A/m
Level 2, 3V
Level 2, 1KV
RF field susceptibility
Magnetic field immunity
Voltage dips , interruption
NOTE
I
II