SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
Note.5
RATED POWER
OUTPUT VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.4
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION Compliance to EN55032 (CISPR32) class A, GB9254 classA, GB17625.1; EN61000-3-2;EN61000-3-3, EAC TP TC 020
EMC IMMUNITY Compliance to EN61000-4-23456811;light industry level,criteria A, EAC TP TC 020,,,,,,
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER LOAD
OVER VOLTAGE
AC CURRENT (Typ.)
2000ms, 100ms/230VAC; 3000ms, 100ms/115VAC at full load
10ms/230VAC; 10ms/115VAC at full load
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
89%
cold start 45A/115VAC, 90A/230VAC
<1mA / 240VAC
13.8 ~ 16.2V
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25 / 70% RH℃
-30 ~ +60 (Refer to output load derating curve)℃
20 ~ 90% RH non-condensing
-30 ~ +85 , 10 ~ 95% RH℃
±℃ ℃)0.1%/ (0 ~ 35
10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
233.422Khrs min. MIL-HDBK-217F (25 )℃
220.4*130*48mm (L*W*H)
1.1Kg; 9pcs / 11Kg / 0.63CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the static characteristics for more details.
5. Please refer to Static Characteristics".
6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.450 450 For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com).
12V
30A
0 ~ 30A
360W
150mVp-p
10.8 ~ 13.2V
±0.5%
±0.5%
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
PROTECTION
ENVIRONMENT
ERPF-400-12
SAFETY STANDARDS
IEC/EN/UL 60950-1,CCC GB4943.1-2011, approvedEAC TP TC 004
OVER TEMPERATURE
Shut down O/P voltage, recovers automatically after temperature goes down
Protection type :Shut down O/P voltage, re-power on to recover
±1.0%
2.5A/230VAC 3A/115VAC
SAFETY &
EMC
()
Note.6
90%
27.6 ~ 32.4V
24V
16.7A
0 ~ 16.7A
400.8W
150mVp-p
21.6 ~ 26.4V
±0.5%
±0.5%
ERPF-400-24
±1.0%
105 ~ 135% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT
Protection type : Constant current limiting, recovers automatically after fault condition is removed
POWER FACTOR (Typ.)
PF 0.95/230VAC, PF 0.98/115VAC≧≧
91%
55.2 ~ 64.8V
48V
8.3A
0 ~ 8.3A
398.4W
240mVp-p
43.2 ~ 52.8V
±0.5%
±0.5%
ERPF-400-48
±1.0%
File Name:ERPF-400-SPEC 2018-03-15