Datasheet
SPECIFICATION
MODEL ELP-75-3.3
ELP-75-12
ELP-75-5 ELP-75-15
ELP-75-24
ELP-75-48
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.6
FREQUENCY RANGE
POWER FACTOR (Typ.)
Note.5
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER LOAD
OVER VOLTAGE
3.3V
12V
5V 15V
24V
48V
15A
6.25A
15A 5A
3.15A
1.6A
0 ~ 15A
0 ~ 6.25A
0 ~ 15A 0 ~ 5A
0 ~ 3.15A
0 ~ 1.6A
49.5W
75W
75W 75W
75.6W
76.8W
80mVp-p
120mVp-p
80mVp-p 150mVp-p
240mVp-p
300mVp-p
3 ~ 3.6V
10.8 ~ 13.2V
4.75 ~ 5.5V 13.5 ~ 16.5V
21.6 ~ 26.4V
43.2 ~ 52.8V
±3.0%
±0.5%
±2.0%
2500ms, 50ms/230VAC 2500ms, 50ms/115VAC at full load
20ms/230VAC 20ms/115VAC at full load
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
3.3V: PF>0.91/230VAC 5V~48V: PF>0.95/230VAC PF>0.98/115VAC at full load
3.7 ~ 4.45V 5.6 ~ 6.75V
13.8 ~ 16.2V
17.25 ~ 20.25V 27.6 ~ 32.4V
53.3 ~ 64.8V
80% 89%82% 90% 90% 90%
1.8A/115VAC 1 A/230VAC
COLD START 60A/230VAC
105 ~ 150% rated output power
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
20 ~ 90% RH non-condensing
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
PCB:175*60*27mm (L*W*H) with optional CASE:195*68.5*33mm (L*W*H)
75W Single Output with PFC Function
ELP-75 series
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
ENVIRONMENT
SAFETY &
EMC
(Note 4)
PROTECTION
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
5. 3.3V PF>0.92/230VAC, others PF>0.95/230VAC.
6. Derating may be needed under low input voltage. Please check the derating curve for more details.
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
■ Features :
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Shut down o/p voltage, re-power on to recover
UL60950-1, TUV EN60950-1 approved
Compliance to EN61000-4-2,3,4,5,6,8,11; EN55024, heavy industry level, criteria A
Universal AC input / Full range
Built-in active PFC function, PF>0.95
High efficiency up to 90%
Optional L-Bracket and cover (ELP-75-x-C, x=3.3,5,12,15,24,36,48)
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection 1U low profile
LED indicator for power on
No load power consumption<0.5W
3 years warranty
<1mA/240VAC
I/P-O/P:3KVAC I/P-FG:2.0KVAC O/P-FG:0.5KVAC
PCB:0.25Kg; 48pcs/13Kg/0.85CUFT with optional CASE:0.54Kg; 25pcs/14.5Kg/0.59CUFT
..
File Name:ELP-75-SPEC 2015-07-17
±2.0%
±0.5%
±1.5%
±2.0%
±0.5%
±1.0%
±2.0%
±0.5%
±1.0%
±1.0%
±0.5%
±1.0%
±1.0%
±0.5%
±1.0%
ELP-75-36
36V
2.1A
0 ~ 2.1A
75.6W
280mVp-p
32.4 ~ 39.6V
±1.0%
±0.5%
±1.0%
90%
39.7 ~ 46.8V
EMC IMMUNITY
EMC EMISSION