Data Sheet

SPECIFICATION
DDR-120 series
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
Note.4
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
DC CURRENT (Typ.)
5A @12Vdc
Protection type : Shut down o/p voltage, re-power on to recover
-40 ~ +70 (Refer to "Derating Curve")
5 ~ 95% RH non-condensing
-40 ~ +85 , 5 ~ 95% RH non-condensing
±℃ 0.03%/ (0 ~ 55 )
Component:10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC61373
214.6K hrs min. MIL-HDBK-217F (25 )
32*125.2*102mm (W*H*D)
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:4KVdc I/P-FG:2.5KVdc O/P-FG:2.5KVdc
I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500Vdc / 25 / 70% RH
ENVIRONMENT
SAFETY &
EMC
(Note 6)
PROTECTION
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
1. All parameters NOT specially mentioned are measured at normal input (A:12Vdc , B:24Vdc) , rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 f & 47 f parallel capacitor.μμ
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the derating curve for more details.
5. 3 seconds max., please refer to peak loading curves.
6. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with
the EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
7. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than℃℃
2000m(6500ft).
PEAK CURRENT
PEAK POWER
Note.5
5A @ 24Vdc
Parameter
Parameter
ESD
Radiated
EFT / Burst
Surge
Conducted
Magnetic Field
Conducted
Radiated
Voltage Flicker
Standard
Standard
EN55032
EN55032
EN61000-3-3
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
Test Level / Note
Test Level / Note
Class B
Class B
-----
EMC IMMUNITY
EMC EMISSION
EN55024 , EN61000-6-2(EN50082-2)
Level 3, 8KV air ; Level 3, 6KV contact; criteria A
Level 3, 10V/m ; criteria A
Level 4, 30A/m ; criteria A
Level 3, 10V ; criteria A
Level 3, 2KV ; criteria A
IEC 62368-1 (LVD), approved; Design refer to UL508EAC TP TC 004, AS/NZS 62368.1
11.2A @12Vdc
Harmonic Current
-----
-----
RAILWAY STANDARD
Compliance to ; Meet EN50155 / IEC60571 including IEC61373 for shock & vibration,EN45545-2 for fire protection
UNDER VOLTAGE LOCKOUT
DDR-120A-12
12V
8.3A
0 ~ 8.3A
99.6W
50mVp-p
9 ~ 14V
±1.0%
±0.5%
±1.0%
12.45A
150W (3sec.)
500ms, 60ms @12Vdc
9 ~ 18Vdc
88.5%
14.4 ~ 16.8V
28.8 ~ 33.6V
24V
4.2A
0 ~ 4.2A
100.8W
50mVp-p
24 ~ 28V
±1.0%
±0.5%
±1.0%
6.3A
DDR-120A-24
88.5%
48V
2.1A
0 ~ 2.1A
100.8W
50mVp-p
48 ~ 56V
±1.0%
±0.5%
±1.0%
3.15A
DDR-120A-48
9 ~ 18Vdc
88.5%
DDR-120B-12
89%
16.8 ~ 33.6Vdc
12V
10A
0 ~ 10A
120W
50mVp-p
9 ~ 14V
±1.0%
±0.5%
±1.0%
15A
DDR-120B-24
89.5%
16.8 ~ 33.6Vdc
24V
5A
0 ~ 5A
120W
50mVp-p
24 ~ 28V
±1.0%
±0.5%
±1.0%
7.5A
DDR-120B-48
91%
16.8 ~ 33.6Vdc
48V
2.5A
0 ~ 2.5A
120W
50mVp-p
48 ~ 56V
±1.0%
±0.5%
±1.0%
3.75A
9 ~ 18Vdc
EN50121-3-2 for EMC (except for 9~18Vin)
57.6 ~ 67.2V
180W (3sec.)
14.4 ~ 16.8V
28.8 ~ 33.6V 57.6 ~ 67.2V
24Vin (B - type) :Power V , FF VON 16.8 O 16.5≥≤
12Vin (A - type) :Power V , FF VON 9 O 8.5≥≤
510g; 28pcs/15.3Kg/1.22CUFT
Normally works within 150% rated output power for more than 3 seconds and then constant current protection 105~135%
rated output power with auto-recovery
120W DIN Rail Type DC-DC Converter
Level 3, 1KV/Line-Line ;Level 3, 2KV/Line-Line-FG ;criteria A
OPERATING ALTITUDE
2000 meters
500ms, 60ms @24Vdc
5.6A @24Vdc
REVERSE POLARITY
By internal MOSFET, no damage, recovers automatically after fault condition removed
File Name:DDR-120-SPEC 2019-08-02
Please refer to page 7 Hold up Time( Load de-rating curve )
EN50155:2007-comply with 3ms@ full load
EN50155:2017-comply with S1 level
INTERRUPTION OF VOLTAGE SUPPLY
EN50155:2007-comply with S1 level (6ms) @ full load, S2 level (10ms) @ 70% load
EN50155:2017-comply with S1 level