SPECIFICATION
MODEL
APC-8E-350
APC-8E-700
OPERATING VOLTAGE RANGE
Note.4
RATED CURRENT
RATED POWER
OUTPUT
SETUP, RISE TIME
VOLTAGE RANGE
Note.3
FREQUENCY RANGE
EFFICIENCY(Typ.)
AC CURRENT
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
SHORT CIRCUIT
11~23V
6~11V
350mA
700mA
8.05W
7.7W
300mVp-p
250mVp-p
500ms, 180ms / 230VAC
47 ~ 63Hz
80.5%
77.5%
0.15A/230VAC
0.25mA / 240VAC
-30 ~ 70 (Refer to "Derating Curve")℃
20 ~ 90% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH℃
±℃ ℃0.2%/ (0 ~45 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Derating may be needed under low input voltage, please check the static characteristic for more details.
4. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. When applying DC voltage for input, please connect the brown input wire to the positive side whereas blue input wire to the negative side.
6. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
7. For any application note and IP water proof function installation caution, please refer our user manual before using.
https://www.meanwell.com/Upload/PDF/LED_EN.pdf
8W Single Output Switching Power Supply
RIPPLE & NOISE
(max.) Note.2
NO LOAD OUTPUT VOLTAGE(max.)
ENVIRONMENT
SAFETY &
EMC
PROTECTION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC
EMC IMMUNITY
Compliance to EN55015,EN61000-3-2 Class A,EN61000-3-3, EAC TP TC 020
Compliance to EN61547,EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV), criteria A, EAC TP TC 020
EMC EMISSION
HOLD UP TIME (Typ.)
20ms/230VAC at full load
Hiccup mode, recovers automatically after fault condition is removed.
60*30*23.5(L*W*H)
COLD START 70A(twidth=120 s measured at 50% Ipeak) at 230VACμ
2275.8K hrs min. MIL-HDBK-217F (25 )℃
I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH℃
180 ~ 264VAC 254 ~ 370VDC ()
Note.5
APC-8E series
CURRENT ACCURACY
±8.0%
APC-8E-500
8~16V
500mA
8W
300mVp-p
79%
APC-8E-250
16~32V
250mA
8W
350mVp-p
81.5%
29V
17V
24V
38V
POWER FACTOR (Typ.) PF>0.5/230VAC at full load
ENEC EN61347-1,EN61347-2-13,EN62384,EAC TP TC 004 approved;
design refer to UL8750,CSA C22.2 No.250.0-08; EN60950-1
0.05Kg; 144pcs/7.6Kg/0.75CUFT
File Name: APC-8E-SPEC 2018-09-29