Instruction manual
6
THE CONTROL PANEL
Power - Lights up when there is power to the dehumidifier, the unit bleeps three times
when it is turned on.
Tank Full - Lights up when the internal tank is full of water and needs to be emptied or
when the tank is incorrectly fitted.
Fault - Lights up when a fault is detected. Most common would be the air inlet
being blocked leading to the dehumidifier over heating internally. Clean the filter; make sure that the
dehumidifier is not next to a heat source (i.e. a radiator) and restart the dehumidifier after ten
minutes.
Fan - Press the Fan button to toggle between the three fan speeds, low, medium and
high. In High fan speed the machine defaults to a Continuous running mode.
Maximum * - Runs the dehumidifier until a relative humidity of 40%rh is achieved
and then goes into fan only mode to circulate the air over the relative humidity sensor so it knows
when to start dehumidifying again.
Normal * - Aims to achieve a relative humidity of 50%rh which will be fine for most
household applications. To prevent condensation on single glazed windows or when the outside
temperature drops below about 5°C you should use Maximum instead of Normal. Once 50%rh has
been achieved the dehumidifier then goes into fan only mode to circulate the air over the relative
humidity sensor so it knows when to start dehumidifying again.
Minimum * - Controls the relative humidity to 60%rh which will prevent mould
from growing in the immediate vicinity of the dehumidifier but not throughout a whole house. Once
60%rh has been reached the dehumidifier then goes into fan only mode to circulate the air over the
relative humidity sensor so it knows when to start dehumidifying again.