User manual
Specifications
• Device for civil use.
• Electronic device independent mounting.
• Power supply: 90-220Vac 50/60Hz
• Relay: 250V maximum voltage, 5A maximum current
with resistive load (2A inductive load).
• 4 operating modes: Manual, Automatic, Jolly, Holidays
• Setting range: from +5°C to +40°C.
• Programming: 24 temperature levels for each day of the
week.
• Detection range temperature: 10 sec.
• Differential: from ± 0.1°C to ± 0.9°C.
• Temperature correction: ± 9°C
• Display Resolution: 0.1°C.
• Accuracy: ± 0.3°C.
• Operating Temperature: 0°C to +50°C.
• Dimensions: 120x80x26 mm.
• Mounting holes compatible with back box italian 503.
26