Setup guide
05-6702A01, Rev. A MDS Orbit MCR-4G 1
MDS Orbit Series: MCR-4G
Setup Guide
This guide provides installation and startup instructions for the
MDS Orbit MCR-4G Managed Connected Router (Figure 1). The
MCR-4G is a highly secure, industrial wireless solution for broad
based applications, including control center monitoring, well site
pad operations, and video surveillance.
The MCR-4G provides wireless communication via cellular and
WiFi technologies in a single, industrial package, without the need
for additional modules or add-ons. In addition, wired serial,
Ethernet, and USB interfaces are provided at the front panel,
reducing network cost and complexity.
MCR-4G units are offered in two different interface offerings; 2
Ethernet/1 Serial (2E1S), or 2 Serial/1 Ethernet (2S1E). The 2E1S
configuration is the standard model and is shown here, although
most information applies equally to both configurations.
Invisible place holder
Figure 1. MCR-4G, Connectors & Indicators
1.1 Technical Manual
This Setup guide covers basic installation and startup instructions
for the unit. A more detailed Technical Manual is also available
(05-6628A01). Refer to the Technical Manual for important
warnings, cautions, and notes. All GE MDS manuals are available
free of charge at www.gemds.com.
Invisible place holder
2.1 Main Requirements
There are three main requirements for installing the unit:
• Adequate and stable primary power (10-60 Vdc)
• Efficient and properly installed antennas for WiFi and/or Cel-
lular service, as applicable
• Correct interface connections between the unit and associ-
ated data equipment.
Figure 2 shows a typical installation of the MCR-4G.
WARNING: When the unit is installed in hazardous locations, use
only the serial or Ethernet connections on the unit’s
front panel. Do not use the USB port in hazardous
locations.
2.2 Installation Steps
Installation details for the product may vary depending on site-spe-
cific factors. The steps here provide the basic tasks needed at
most sites.
1. Mount the unit. Attach the supplied brackets to the bottom of
the case (if not already attached), using the screws provided.
Mounting bracket dimensions are shown in Figure 3. If DIN
Rail mounting brackets are to be used, consult the Technical
Manual for details.
NOTE: To prevent moisture from entering the unit, do not mount
the case with the cable connectors pointing up. Also,
dress all cables to prevent moisture from running along
the cables and into the enclosure.
Figure 2. Typical MCR-4G Installation
Figure 3. Mounting Bracket Dimensions
2. Install the antennas and feedlines. The antennas used must
be designed to operate in the appropriate frequency band,
and be mounted in a location providing a clear path to the
associated station(s). Antennas should be mounted away
from large masses of metal and other obstructions.
1.0 INTRODUCTION
2.0 INSTALLATION
DC Power
(10-60 Vdc)
Ethernet Ports
(RJ-45 10/100)
Mini USB
Port
Cellular
Antennas
(Aux & Main)
SIM Card
Slot
COM Port
(RJ-45)
WiFi Antenna
LED Indicator
Panel
DC INPUT
(10-60 Vdc)
Ethernet
Serial
WiFi Antenna
(Cabled)
Main Cell Antenna
(TX/RX)
Diversity
Cell Antenna
(RX)
PC for Configuration
(Serial, Ethernet, USB)
USB
8.5 (21.59 cm)
9.25 (23.5 cm)
4.81 (12.22 cm)