Specifications
Table Of Contents
- Preface
- Quick Start Guide
- Table of Contents
- Chapter 1 General Information
- Functional Description
- Physical Description
- Application Considerations
- Basic MX-2100 System
- Redundancy (not for MX-2104)
- Dual Link Operation (not for MX-2104)
- Priority Bumping \(not for MX2104\)
- Switched Backup Operation (not for MX-2104)
- Switch Mode
- System Management
- System Timing Considerations
- DTE Timing (KML.1, KML.2, KML.3, KML.4 and KML.10 Modules)
- External DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- Internal Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- Loopback Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- DCE Timing (KML.7, KML.8, and KML.F Modules)
- Main Link Timing Considerations in Bypassing and Multidrop Configurations
- Data Channel Clock Modes
- Timing Modes of ISDN Channels
- Sub Link Timing
- Main Link Interface Characteristics
- V.35 Interface (Module KML.1)
- RS-232 Interface (Module KML.2)
- V.36/RS-422/RS-530 Interface (Module KML.3)
- X.21 Interface (Module KML.4)
- G.703 Codirectional Interface (Module KML.5)
- Standard DDS CSU/DSU (Module KML.6)
- T1 Link Interface (Module KML.7)
- E1 Link Interface (Module KML.8)
- ISDN "S" Interface (Module KML.10/S)
- ISDN "U" Interface (Module KML.10/U)
- Fiber-Optic Link Interface (Module KML.F)
- I/O Module Applications
- Technical System Characteristics
- Chapter 2 Installation
- Introduction
- Site Requirements and Prerequisites
- Input Power Requirements
- Grounding
- Channel Connection Considerations
- Front and Rear Panel Clearance
- Ambient Requirements
- Electromagnetic Compatibility Considerations
- Current and Power Requirements of MX-2100 Power Supply Modules
- Current and Power Capabilities of MX-2100 Power Supply Modules
- Ratings of Ring and Feed Voltage Supplies
- Equipment Needed
- Package Contents
- Installation and Setup of MX-2100
- Interfaces and Connections
- Initial Setup and Configuration
- Chapter 3 Configuring MX-2100
- Chapter 4 Operation
- Chapter 5 Diagnostics
- Appendix A Connection Data
- Appendix B Alarms
- Appendix C SNMP Management
- Appendix D Software Download
- Appendix E Configuration Parameters
- Appendix F Command Set Description
- General
- Commands
- BYE
- CLR ALM
- CLR LOOP
- CLR MONITOR
- CONNECT SWITCH
- DATE
- DEF AGENDA
- DEF AGENT
- DEF ALM DEBOUNCE
- DEF CALL
- DEF CH
- DEF CON
- DEF DB FLIP
- DEF DP
- DEF FRAME
- DEF MANAGER LIST
- DEF ML
- DEF ML CALL
- DEF NAME
- DEF NODE
- DEF NP
- DEF PWD
- DEF ROUTE
- DEF SP
- DEF SYS
- DISCONNECT SWITCH
- DSP AGENT
- DSP ALM
- DSP BERT
- DSP CH CON
- DSP FLIP
- DSP HDR TST
- DSP MANAGER LIST
- DSP KVF5orDSP PBX
- DSP KVF6
- DSP SIGNALINGorDSP SIG
- DSP PRBS_INJ
- DSP REM AGENT
- DSP REV
- DSP ST FRAME
- DSP ST ML
- DSP ST SLOT
- DSP ST SYS
- EDIT DB
- EXIT
- F
- FLIP ML
- HELP
- INIT DB
- INIT F
- LOAD DB 1\2
- LOAD IO
- LOOP
- ML RECOVERY
- MONITOR
- REBUILD FRAME
- RESET LOC
- RESET IO
- RESET ML
- TIME
- UPDATE DB 1\2
- Index
- DC Power Supply Connection

MX-2100/2104 Installation and Operation Manual Chapter 2 Installation
Interfaces and Connections 2-19
Table 2-7. Module KCL.2, Rear Panel (Cont.)
Item Function
External DIP switch (SW2)
Described in
Table 2-5
ALM RLY connector 6-pin RJ-12 connector with dry contacts for relaying alarms from the
MX-2100 to activate external equipment (such as lamps, buzzers, fans).
The Alarm Relay connector can also be used to relay external
equipment information to the MX-2100 (such as external sensor
information, or fan failure).
Connector rating: Max current is 500 mA, Max voltage is 50V
For pinout refer to
Appendix A.
Connections to the Supervisory Port – KCL.2 Module
Find the supervision cable intended for connection to the enclosure, and connect
it to the SP connector on the KCL.2 module.
If the optional dial-out port is to be used, connect the corresponding cable to the
MNG connector on the KCL.2 module.
Connections to the Alarm Relay Connector – KCL.2 Module
Connect the external equipment to the RJ-12 Alarm Relay connector according to
the pin assignment described in Appendix A.
The connector functions as a dry contact relay. Under normal conditions, the
Normally Closed (NC) pin is shorted with the Common contact. When a MX-2100
alarm occurs, the Common contact will instead be shorted to the Normally Open
(NO) pin and the device connected to the connector will be activated (similarly to
how the Alarm LED on the MX-2100 front panel is activated).
Connections to KML, Options, I/O Modules, and Ringers
Refer to the corresponding module/ringer Installation and Operation Manual.
MX-2104
Rear Panel
Figure 2-6 shows a typical rear view of the MX-2104 enclosure and identifies the
I/O slots.
Table 2-8 explains the components located on the MX-2104 rear panel.
∼
FUSE
X.21
ALM RLY
ON
Power
MNG
CONTROL
100-240VAC
0.8A T 250V
1234
ALM
TST
RST
1
54 7 8
9
3
2
Figure 2-6. MX-2104 Enclosure, Typical Rear View