Specifications
Table Of Contents
- Preface
- Quick Start Guide
- Table of Contents
- Chapter 1 General Information
- Functional Description
- Physical Description
- Application Considerations
- Basic MX-2100 System
- Redundancy (not for MX-2104)
- Dual Link Operation (not for MX-2104)
- Priority Bumping \(not for MX2104\)
- Switched Backup Operation (not for MX-2104)
- Switch Mode
- System Management
- System Timing Considerations
- DTE Timing (KML.1, KML.2, KML.3, KML.4 and KML.10 Modules)
- External DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- Internal Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- Loopback Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- DCE Timing (KML.7, KML.8, and KML.F Modules)
- Main Link Timing Considerations in Bypassing and Multidrop Configurations
- Data Channel Clock Modes
- Timing Modes of ISDN Channels
- Sub Link Timing
- Main Link Interface Characteristics
- V.35 Interface (Module KML.1)
- RS-232 Interface (Module KML.2)
- V.36/RS-422/RS-530 Interface (Module KML.3)
- X.21 Interface (Module KML.4)
- G.703 Codirectional Interface (Module KML.5)
- Standard DDS CSU/DSU (Module KML.6)
- T1 Link Interface (Module KML.7)
- E1 Link Interface (Module KML.8)
- ISDN "S" Interface (Module KML.10/S)
- ISDN "U" Interface (Module KML.10/U)
- Fiber-Optic Link Interface (Module KML.F)
- I/O Module Applications
- Technical System Characteristics
- Chapter 2 Installation
- Introduction
- Site Requirements and Prerequisites
- Input Power Requirements
- Grounding
- Channel Connection Considerations
- Front and Rear Panel Clearance
- Ambient Requirements
- Electromagnetic Compatibility Considerations
- Current and Power Requirements of MX-2100 Power Supply Modules
- Current and Power Capabilities of MX-2100 Power Supply Modules
- Ratings of Ring and Feed Voltage Supplies
- Equipment Needed
- Package Contents
- Installation and Setup of MX-2100
- Interfaces and Connections
- Initial Setup and Configuration
- Chapter 3 Configuring MX-2100
- Chapter 4 Operation
- Chapter 5 Diagnostics
- Appendix A Connection Data
- Appendix B Alarms
- Appendix C SNMP Management
- Appendix D Software Download
- Appendix E Configuration Parameters
- Appendix F Command Set Description
- General
- Commands
- BYE
- CLR ALM
- CLR LOOP
- CLR MONITOR
- CONNECT SWITCH
- DATE
- DEF AGENDA
- DEF AGENT
- DEF ALM DEBOUNCE
- DEF CALL
- DEF CH
- DEF CON
- DEF DB FLIP
- DEF DP
- DEF FRAME
- DEF MANAGER LIST
- DEF ML
- DEF ML CALL
- DEF NAME
- DEF NODE
- DEF NP
- DEF PWD
- DEF ROUTE
- DEF SP
- DEF SYS
- DISCONNECT SWITCH
- DSP AGENT
- DSP ALM
- DSP BERT
- DSP CH CON
- DSP FLIP
- DSP HDR TST
- DSP MANAGER LIST
- DSP KVF5orDSP PBX
- DSP KVF6
- DSP SIGNALINGorDSP SIG
- DSP PRBS_INJ
- DSP REM AGENT
- DSP REV
- DSP ST FRAME
- DSP ST ML
- DSP ST SLOT
- DSP ST SYS
- EDIT DB
- EXIT
- F
- FLIP ML
- HELP
- INIT DB
- INIT F
- LOAD DB 1\2
- LOAD IO
- LOOP
- ML RECOVERY
- MONITOR
- REBUILD FRAME
- RESET LOC
- RESET IO
- RESET ML
- TIME
- UPDATE DB 1\2
- Index
- DC Power Supply Connection

MX-2100/2104 Installation and Operation Manual Chapter 2 Installation
Interfaces and Connections 2-17
M
M M
o
o o
d
d d
u
u u
l
l l
e
e e
K
K K
P
P P
S
S S
.
. .
3
5 7
KPS.3
KPS.5 KPS.7
POWER
POWER POWER
P
P P
o
o o
w
w w
e
e e
r
r r
C
C C
o
o o
n
n n
n
n n
e
e e
c
c c
t
t t
o
o o
r
r r
O
O O
N
N N
/
/ /
O
O O
F
F F
F
F F
S
S S
w
w w
i
i i
t
t t
c
c c
h
h h
G
G G
r
r r
o
o o
u
u u
n
n n
d
d d
i
i i
n
n n
g
g g
T
T T
e
e e
r
r r
m
m m
i
i i
n
n n
a
a a
l
l l
Module KPS.6
KPS
Fuse
Power
Connector
Label
(Supply
Voltage)
CAU TION
:
FOR CONTINUE D
PROTECTION AGAINST RISK OF
FIRE , REPL ACE ONL Y WI TH S AM E
TYPE AND RATING OF FUSE.
PS.6
100-240VAC
3A T 250V
POWER
ON/OFF
Switch
Grounding
Terminal
Module KPS.4
KPS
Fuse
Power
Connector
Label
(Supply
Voltage)
CAUTION
:
FOR CONTI NUED
PR OT ECT IO N AG AI NST RIS K O F
FIRE , RE PLACE O NLY WITH SAME
TYPE AND RATI NG OF FUSE.
PS.4
100-240VAC
3A T 250V
POWER
ON/OFF
Switch
Grounding
Terminal
-48
-24
0
0
VDC-IN
VDC-IN
48V
-
+
Figure 2-4. KPS Modules, Rear Panels
Power Connection
3. Check that the ON/OFF switches on the KPS modules are set to OFF. Refer to
Figure 2-4.
4. Connect the power cable first to the connector on the KPS module, then to
the mains outlet. Refer to Figure 2-4.
When redundant power supplies are used, it is recommended to connect the
power cables to outlets powered by different circuits.
The KPS.3 and KPS.5 modules do not have a power switch, and will start operating
as soon as power is connected.
KCL.2 Module
Rear Panel
Figure 2-5 shows the rear panels of the KCL.2 module. The KCL.2 is ordered with
one of the following three Management Port interfaces:
• 9-pin Dial Port
• UTP Ethernet interface
• BNC Ethernet interface.
Table 2-7 describes the functions of the panel components.
Note