Specifications
Table Of Contents
- Preface
- Quick Start Guide
- Table of Contents
- Chapter 1 General Information
- Functional Description
- Physical Description
- Application Considerations
- Basic MX-2100 System
- Redundancy (not for MX-2104)
- Dual Link Operation (not for MX-2104)
- Priority Bumping \(not for MX2104\)
- Switched Backup Operation (not for MX-2104)
- Switch Mode
- System Management
- System Timing Considerations
- DTE Timing (KML.1, KML.2, KML.3, KML.4 and KML.10 Modules)
- External DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- Internal Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- Loopback Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- DCE Timing (KML.7, KML.8, and KML.F Modules)
- Main Link Timing Considerations in Bypassing and Multidrop Configurations
- Data Channel Clock Modes
- Timing Modes of ISDN Channels
- Sub Link Timing
- Main Link Interface Characteristics
- V.35 Interface (Module KML.1)
- RS-232 Interface (Module KML.2)
- V.36/RS-422/RS-530 Interface (Module KML.3)
- X.21 Interface (Module KML.4)
- G.703 Codirectional Interface (Module KML.5)
- Standard DDS CSU/DSU (Module KML.6)
- T1 Link Interface (Module KML.7)
- E1 Link Interface (Module KML.8)
- ISDN "S" Interface (Module KML.10/S)
- ISDN "U" Interface (Module KML.10/U)
- Fiber-Optic Link Interface (Module KML.F)
- I/O Module Applications
- Technical System Characteristics
- Chapter 2 Installation
- Introduction
- Site Requirements and Prerequisites
- Input Power Requirements
- Grounding
- Channel Connection Considerations
- Front and Rear Panel Clearance
- Ambient Requirements
- Electromagnetic Compatibility Considerations
- Current and Power Requirements of MX-2100 Power Supply Modules
- Current and Power Capabilities of MX-2100 Power Supply Modules
- Ratings of Ring and Feed Voltage Supplies
- Equipment Needed
- Package Contents
- Installation and Setup of MX-2100
- Interfaces and Connections
- Initial Setup and Configuration
- Chapter 3 Configuring MX-2100
- Chapter 4 Operation
- Chapter 5 Diagnostics
- Appendix A Connection Data
- Appendix B Alarms
- Appendix C SNMP Management
- Appendix D Software Download
- Appendix E Configuration Parameters
- Appendix F Command Set Description
- General
- Commands
- BYE
- CLR ALM
- CLR LOOP
- CLR MONITOR
- CONNECT SWITCH
- DATE
- DEF AGENDA
- DEF AGENT
- DEF ALM DEBOUNCE
- DEF CALL
- DEF CH
- DEF CON
- DEF DB FLIP
- DEF DP
- DEF FRAME
- DEF MANAGER LIST
- DEF ML
- DEF ML CALL
- DEF NAME
- DEF NODE
- DEF NP
- DEF PWD
- DEF ROUTE
- DEF SP
- DEF SYS
- DISCONNECT SWITCH
- DSP AGENT
- DSP ALM
- DSP BERT
- DSP CH CON
- DSP FLIP
- DSP HDR TST
- DSP MANAGER LIST
- DSP KVF5orDSP PBX
- DSP KVF6
- DSP SIGNALINGorDSP SIG
- DSP PRBS_INJ
- DSP REM AGENT
- DSP REV
- DSP ST FRAME
- DSP ST ML
- DSP ST SLOT
- DSP ST SYS
- EDIT DB
- EXIT
- F
- FLIP ML
- HELP
- INIT DB
- INIT F
- LOAD DB 1\2
- LOAD IO
- LOOP
- ML RECOVERY
- MONITOR
- REBUILD FRAME
- RESET LOC
- RESET IO
- RESET ML
- TIME
- UPDATE DB 1\2
- Index
- DC Power Supply Connection

MX-2100/2104 Installation and Operation Manual Chapter 2 Installation
Installation and Setup of MX-2100 2-13
The enclosure is fastened to the rack by four screws (two on each side). Do not
connect power to the enclosure before it is installed in the designated position.
KPS Module
Setting the Internal Jumpers
The KPS modules include one internal jumper, designated FG=SG. The location
of the jumper is shown in Figure 2-2. This jumper controls the connection between
the internal signal ground and the frame (enclosure) ground. The module is
delivered with the jumper set to YES. Set the jumper to NO if you need the signal
ground to float with respect to the frame ground. If redundant modules are
installed, make sure that the jumper is set to the same position on both modules.
SGND = FGND
YES
NO
Signal Ground Connected to
Frame Ground
Signal Ground not Connected
to Frame Ground
YES
NO
Figure 2-2. Typical KPS Module, Location of Internal Jumper
Installing the KPS Module
➤ To install the KPS module:
1. Insert the KPS module in slot 1.
2. If an additional redundant module is used for MX-2100 only, install it in slot 2.
For example, a KPS.7 module can be used as a backup to an AC power supply
module with similar rating, e.g., KPS.6.
You can install a redundant module in an operating enclosure without turning off
the enclosure power. In this case, after the module is installed, connect its power
cable and set its power switch to ON.
Note