Specifications
Table Of Contents
- Preface
- Quick Start Guide
- Table of Contents
- Chapter 1 General Information
- Functional Description
- Physical Description
- Application Considerations
- Basic MX-2100 System
- Redundancy (not for MX-2104)
- Dual Link Operation (not for MX-2104)
- Priority Bumping \(not for MX2104\)
- Switched Backup Operation (not for MX-2104)
- Switch Mode
- System Management
- System Timing Considerations
- DTE Timing (KML.1, KML.2, KML.3, KML.4 and KML.10 Modules)
- External DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- Internal Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- Loopback Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- DCE Timing (KML.7, KML.8, and KML.F Modules)
- Main Link Timing Considerations in Bypassing and Multidrop Configurations
- Data Channel Clock Modes
- Timing Modes of ISDN Channels
- Sub Link Timing
- Main Link Interface Characteristics
- V.35 Interface (Module KML.1)
- RS-232 Interface (Module KML.2)
- V.36/RS-422/RS-530 Interface (Module KML.3)
- X.21 Interface (Module KML.4)
- G.703 Codirectional Interface (Module KML.5)
- Standard DDS CSU/DSU (Module KML.6)
- T1 Link Interface (Module KML.7)
- E1 Link Interface (Module KML.8)
- ISDN "S" Interface (Module KML.10/S)
- ISDN "U" Interface (Module KML.10/U)
- Fiber-Optic Link Interface (Module KML.F)
- I/O Module Applications
- Technical System Characteristics
- Chapter 2 Installation
- Introduction
- Site Requirements and Prerequisites
- Input Power Requirements
- Grounding
- Channel Connection Considerations
- Front and Rear Panel Clearance
- Ambient Requirements
- Electromagnetic Compatibility Considerations
- Current and Power Requirements of MX-2100 Power Supply Modules
- Current and Power Capabilities of MX-2100 Power Supply Modules
- Ratings of Ring and Feed Voltage Supplies
- Equipment Needed
- Package Contents
- Installation and Setup of MX-2100
- Interfaces and Connections
- Initial Setup and Configuration
- Chapter 3 Configuring MX-2100
- Chapter 4 Operation
- Chapter 5 Diagnostics
- Appendix A Connection Data
- Appendix B Alarms
- Appendix C SNMP Management
- Appendix D Software Download
- Appendix E Configuration Parameters
- Appendix F Command Set Description
- General
- Commands
- BYE
- CLR ALM
- CLR LOOP
- CLR MONITOR
- CONNECT SWITCH
- DATE
- DEF AGENDA
- DEF AGENT
- DEF ALM DEBOUNCE
- DEF CALL
- DEF CH
- DEF CON
- DEF DB FLIP
- DEF DP
- DEF FRAME
- DEF MANAGER LIST
- DEF ML
- DEF ML CALL
- DEF NAME
- DEF NODE
- DEF NP
- DEF PWD
- DEF ROUTE
- DEF SP
- DEF SYS
- DISCONNECT SWITCH
- DSP AGENT
- DSP ALM
- DSP BERT
- DSP CH CON
- DSP FLIP
- DSP HDR TST
- DSP MANAGER LIST
- DSP KVF5orDSP PBX
- DSP KVF6
- DSP SIGNALINGorDSP SIG
- DSP PRBS_INJ
- DSP REM AGENT
- DSP REV
- DSP ST FRAME
- DSP ST ML
- DSP ST SLOT
- DSP ST SYS
- EDIT DB
- EXIT
- F
- FLIP ML
- HELP
- INIT DB
- INIT F
- LOAD DB 1\2
- LOAD IO
- LOOP
- ML RECOVERY
- MONITOR
- REBUILD FRAME
- RESET LOC
- RESET IO
- RESET ML
- TIME
- UPDATE DB 1\2
- Index
- DC Power Supply Connection

Chapter 2 Installation MX-2100/2104 Installation and Operation Manual
2-10 Equipment Needed
Clear to Send (CTS)
The state of the CTS line is determined by the CTS parameter:
• ON - The CTS line is always ON (active)
• =RTS - The CTS line follows the RTS line.
Data Carrier Detect (DCD)
The state of the DCD line depends on the communication address (node number):
• When the node address is 0, the DCD line is always ON (active).
• When a non-zero node address is used (multidrop operation), the DCD line is
switched ON (active) when data is detected on the RD line, provided
MX-2100 recognizes its own address in the data stream. To simulate DTE
operation, the delay between these events can be set by the user (by means of
the DCD_DEL parameter).
Ring Indication (RI)
The RI line is used only with dial-up modems (DTE interface mode).
The RI line is normally OFF (inactive); when the modem attached to the MX-2100
SP connector detects an incoming call, the RI line is switched ON (active). See also
the DSR line.
Data Set Ready (DSR)
• Usually, the DSR line is configured to track the DTR line. In this case, if the
supervisory port interface is DTE, the DSR line will be switched ON for 5
seconds when the RI line is ON while the DTR line is OFF.
• If the supervisory port interface is DCE, the DSR line can also be configured to
be continuously ON. However, if the DTR line switches to OFF, the DSR line
will also switch to OFF for 5 seconds.
In addition, MX-2100 always switches the DSR line OFF (inactive) for 5
seconds when the EXIT command is executed, and when the disconnect
time-out expires.
AUTOBAUD Function
When the AUTOBAUD function is enabled, MX-2100 can identify the rate of
incoming data by analyzing the timing of three consecutive pairs of Carriage
Return and Line Feed characters (generated by pressing three times the carriage
return key). The detected data rate is then used for the current communication
session. The automatic baud rate identification procedure is performed (or
repeated) whenever three consecutive carriage returns are received after one of
the following events occurs:
• The DTR line has been switched OFF
• The EXIT command has been executed
• The idle disconnect time-out expired because no data has been exchanged
with the supervision terminal.
In case one of these events occurred, MX-2100 assumes that the current
communication session has been terminated. Therefore, when the password
protection is enabled the password must be entered again before the supervision
terminal can resume communication with MX-2100.