Specifications
Table Of Contents
- Preface
- Quick Start Guide
- Table of Contents
- Chapter 1 General Information
- Functional Description
- Physical Description
- Application Considerations
- Basic MX-2100 System
- Redundancy (not for MX-2104)
- Dual Link Operation (not for MX-2104)
- Priority Bumping \(not for MX2104\)
- Switched Backup Operation (not for MX-2104)
- Switch Mode
- System Management
- System Timing Considerations
- DTE Timing (KML.1, KML.2, KML.3, KML.4 and KML.10 Modules)
- External DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- Internal Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- Loopback Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- DCE Timing (KML.7, KML.8, and KML.F Modules)
- Main Link Timing Considerations in Bypassing and Multidrop Configurations
- Data Channel Clock Modes
- Timing Modes of ISDN Channels
- Sub Link Timing
- Main Link Interface Characteristics
- V.35 Interface (Module KML.1)
- RS-232 Interface (Module KML.2)
- V.36/RS-422/RS-530 Interface (Module KML.3)
- X.21 Interface (Module KML.4)
- G.703 Codirectional Interface (Module KML.5)
- Standard DDS CSU/DSU (Module KML.6)
- T1 Link Interface (Module KML.7)
- E1 Link Interface (Module KML.8)
- ISDN "S" Interface (Module KML.10/S)
- ISDN "U" Interface (Module KML.10/U)
- Fiber-Optic Link Interface (Module KML.F)
- I/O Module Applications
- Technical System Characteristics
- Chapter 2 Installation
- Introduction
- Site Requirements and Prerequisites
- Input Power Requirements
- Grounding
- Channel Connection Considerations
- Front and Rear Panel Clearance
- Ambient Requirements
- Electromagnetic Compatibility Considerations
- Current and Power Requirements of MX-2100 Power Supply Modules
- Current and Power Capabilities of MX-2100 Power Supply Modules
- Ratings of Ring and Feed Voltage Supplies
- Equipment Needed
- Package Contents
- Installation and Setup of MX-2100
- Interfaces and Connections
- Initial Setup and Configuration
- Chapter 3 Configuring MX-2100
- Chapter 4 Operation
- Chapter 5 Diagnostics
- Appendix A Connection Data
- Appendix B Alarms
- Appendix C SNMP Management
- Appendix D Software Download
- Appendix E Configuration Parameters
- Appendix F Command Set Description
- General
- Commands
- BYE
- CLR ALM
- CLR LOOP
- CLR MONITOR
- CONNECT SWITCH
- DATE
- DEF AGENDA
- DEF AGENT
- DEF ALM DEBOUNCE
- DEF CALL
- DEF CH
- DEF CON
- DEF DB FLIP
- DEF DP
- DEF FRAME
- DEF MANAGER LIST
- DEF ML
- DEF ML CALL
- DEF NAME
- DEF NODE
- DEF NP
- DEF PWD
- DEF ROUTE
- DEF SP
- DEF SYS
- DISCONNECT SWITCH
- DSP AGENT
- DSP ALM
- DSP BERT
- DSP CH CON
- DSP FLIP
- DSP HDR TST
- DSP MANAGER LIST
- DSP KVF5orDSP PBX
- DSP KVF6
- DSP SIGNALINGorDSP SIG
- DSP PRBS_INJ
- DSP REM AGENT
- DSP REV
- DSP ST FRAME
- DSP ST ML
- DSP ST SLOT
- DSP ST SYS
- EDIT DB
- EXIT
- F
- FLIP ML
- HELP
- INIT DB
- INIT F
- LOAD DB 1\2
- LOAD IO
- LOOP
- ML RECOVERY
- MONITOR
- REBUILD FRAME
- RESET LOC
- RESET IO
- RESET ML
- TIME
- UPDATE DB 1\2
- Index
- DC Power Supply Connection

MX-2100/2104 Installation and Operation Manual Chapter 2 Installation
Equipment Needed 2-9
The user can select, for each port, the data rate (9.6, 19.2, 38.4, 57.6 kbps), and
the word format (number of data bits, parity type, and number of stop bits). The
default communication data rate is 9.6 kbps. The default word format consists of
one start bit, eight data bits, no parity, and one stop bit.
The SP (CONTROL-DCE) supervisory port continuously monitors the incoming
data stream and will immediately respond to any input string received through this
port.
Connection of Supervision Terminal
A supervision terminal can be connected either directly to the MX-2100 SP
(CONTROL-DCE) supervisory port, or through a modem or any other type of
full-duplex data link. MX-2100 supports only a dial-in connection.
Handshaking Protocol - CONTROL DCE Port
The handshaking between MX-2100 and the equipment connected to it
(supervision terminal, SNMP management station, modem, etc.) uses the control
lines in the MX-2100 SP connector.
The control lines being used in the DCE and DTE interfacing mode, and the
direction of the control signals, are detailed in the following chart.
Table 2-3. DCE and DTE Interfacing Mode - Control Lines
Interface Type Control Line
DCE DTE
CTS Out Not used
DCD Out Out
DSR Out Out
DTR In In
RI Not used In
RTS In In
Data Terminal Ready (DTR)
The equipment connected to the SP port must set the DTR line ON (active) to gain
control over MX-2100 and start a management session. When the DTR is ON, the
MX-2100 front panel controls are disabled, and the LCD shows: TERMINAL ON
LINE.
To end the current session, the DTR line is switched OFF (inactive). This ends the
control connection, and returns the control to the MX-2100 front panel. If
password protection is used, the password must be entered again the next time the
DTR line is switched ON to start a new session.
Request to Send (RTS)
The RTS line is normally ON (active) during a management session.
When the RTS line is OFF (inactive), MX-2100 interprets any data received from
the terminal on the TD line as MARK.