Specifications
Table Of Contents
- Preface
- Quick Start Guide
- Table of Contents
- Chapter 1 General Information
- Functional Description
- Physical Description
- Application Considerations
- Basic MX-2100 System
- Redundancy (not for MX-2104)
- Dual Link Operation (not for MX-2104)
- Priority Bumping \(not for MX2104\)
- Switched Backup Operation (not for MX-2104)
- Switch Mode
- System Management
- System Timing Considerations
- DTE Timing (KML.1, KML.2, KML.3, KML.4 and KML.10 Modules)
- External DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- Internal Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- Loopback Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- DCE Timing (KML.7, KML.8, and KML.F Modules)
- Main Link Timing Considerations in Bypassing and Multidrop Configurations
- Data Channel Clock Modes
- Timing Modes of ISDN Channels
- Sub Link Timing
- Main Link Interface Characteristics
- V.35 Interface (Module KML.1)
- RS-232 Interface (Module KML.2)
- V.36/RS-422/RS-530 Interface (Module KML.3)
- X.21 Interface (Module KML.4)
- G.703 Codirectional Interface (Module KML.5)
- Standard DDS CSU/DSU (Module KML.6)
- T1 Link Interface (Module KML.7)
- E1 Link Interface (Module KML.8)
- ISDN "S" Interface (Module KML.10/S)
- ISDN "U" Interface (Module KML.10/U)
- Fiber-Optic Link Interface (Module KML.F)
- I/O Module Applications
- Technical System Characteristics
- Chapter 2 Installation
- Introduction
- Site Requirements and Prerequisites
- Input Power Requirements
- Grounding
- Channel Connection Considerations
- Front and Rear Panel Clearance
- Ambient Requirements
- Electromagnetic Compatibility Considerations
- Current and Power Requirements of MX-2100 Power Supply Modules
- Current and Power Capabilities of MX-2100 Power Supply Modules
- Ratings of Ring and Feed Voltage Supplies
- Equipment Needed
- Package Contents
- Installation and Setup of MX-2100
- Interfaces and Connections
- Initial Setup and Configuration
- Chapter 3 Configuring MX-2100
- Chapter 4 Operation
- Chapter 5 Diagnostics
- Appendix A Connection Data
- Appendix B Alarms
- Appendix C SNMP Management
- Appendix D Software Download
- Appendix E Configuration Parameters
- Appendix F Command Set Description
- General
- Commands
- BYE
- CLR ALM
- CLR LOOP
- CLR MONITOR
- CONNECT SWITCH
- DATE
- DEF AGENDA
- DEF AGENT
- DEF ALM DEBOUNCE
- DEF CALL
- DEF CH
- DEF CON
- DEF DB FLIP
- DEF DP
- DEF FRAME
- DEF MANAGER LIST
- DEF ML
- DEF ML CALL
- DEF NAME
- DEF NODE
- DEF NP
- DEF PWD
- DEF ROUTE
- DEF SP
- DEF SYS
- DISCONNECT SWITCH
- DSP AGENT
- DSP ALM
- DSP BERT
- DSP CH CON
- DSP FLIP
- DSP HDR TST
- DSP MANAGER LIST
- DSP KVF5orDSP PBX
- DSP KVF6
- DSP SIGNALINGorDSP SIG
- DSP PRBS_INJ
- DSP REM AGENT
- DSP REV
- DSP ST FRAME
- DSP ST ML
- DSP ST SLOT
- DSP ST SYS
- EDIT DB
- EXIT
- F
- FLIP ML
- HELP
- INIT DB
- INIT F
- LOAD DB 1\2
- LOAD IO
- LOOP
- ML RECOVERY
- MONITOR
- REBUILD FRAME
- RESET LOC
- RESET IO
- RESET ML
- TIME
- UPDATE DB 1\2
- Index
- DC Power Supply Connection

Chapter 2 Installation MX-2100/2104 Installation and Operation Manual
2-8 Equipment Needed
Ringer-2000
Ringer-2000 is a standalone power supply unit that can provide power for up to
60 voice channels. Ringer-2000 is intended for installation on shelves or in 19"
racks. Unit height is only 1U. Ringer-2000 is available in AC (115 VAC or
230 VAC) or DC (-24 VDC or -48 VDC) power supply versions.
Ringer-2200
Ringer-2200 is an enhanced standalone power supply unit that can provide
power for up to 120 voice channels. This is enough power for a MX-2100 chassis
fully equipped with 12 KVF.8 modules (96 channels). Ringer-2200 is intended for
installation on shelves or in 19" racks. Unit height is only 1U. Ringer-2200 is
available in 115 VAC or 230 VAC power supply versions.
KM-Ringer
KM-Ringer can provide power for up to 32 voice channels (or 24 KVF.8 channels).
KM-Ringer is a small unit that can be located on shelves and desktops, or installed
as a plug-in module in a 3U high MX-2100 enclosure only. It occupies three I/O
enclosure slots. KM-Ringer is available in AC (115 to 230 VAC) or DC (-24 VDC or
-48 VDC) power supply versions.
For details see the appropriate Ringer Installation and Operation Manual.
2.3 Equipment Needed
The following describes the equipment needed to run the MX-2100.
Terminal Characteristics
Any standard ASCII terminal or PC emulating an ASCII terminal equipped with an
RS-232 communication interface can be used to control MX-2100 operation.
Make sure to initialize MX-2100 for correct terminal operation as explained in
Initial Setup and Configuration on page 2-21, otherwise some commands may not
work properly.
Software Requirements
The software necessary to run the MX-2100 supervision program is contained in
the program EPROM of the KCL.2 module of the MX-2100. MX-2100 stores all the
configuration information generated or altered during the communication with the
terminal. No information is stored in the terminal.
Supervisory Port Interface Characteristics
MX-2100 has an RS-232 asynchronous DCE port, designated Supervisory Port
Connector (CONTROL-DCE), located on the KCL.2 module. This port has a 9-pin
D-type female connector, and is intended for direct connection to terminals. Since
terminals usually have DTE interfaces, the connection to this port is made by
means of a straight-through cable. For connection to a modem, you need a
cross-cable (null modem cable).