Specifications
Table Of Contents
- Preface
- Quick Start Guide
- Table of Contents
- Chapter 1 General Information
- Functional Description
- Physical Description
- Application Considerations
- Basic MX-2100 System
- Redundancy (not for MX-2104)
- Dual Link Operation (not for MX-2104)
- Priority Bumping \(not for MX2104\)
- Switched Backup Operation (not for MX-2104)
- Switch Mode
- System Management
- System Timing Considerations
- DTE Timing (KML.1, KML.2, KML.3, KML.4 and KML.10 Modules)
- External DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- Internal Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- Loopback Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- DCE Timing (KML.7, KML.8, and KML.F Modules)
- Main Link Timing Considerations in Bypassing and Multidrop Configurations
- Data Channel Clock Modes
- Timing Modes of ISDN Channels
- Sub Link Timing
- Main Link Interface Characteristics
- V.35 Interface (Module KML.1)
- RS-232 Interface (Module KML.2)
- V.36/RS-422/RS-530 Interface (Module KML.3)
- X.21 Interface (Module KML.4)
- G.703 Codirectional Interface (Module KML.5)
- Standard DDS CSU/DSU (Module KML.6)
- T1 Link Interface (Module KML.7)
- E1 Link Interface (Module KML.8)
- ISDN "S" Interface (Module KML.10/S)
- ISDN "U" Interface (Module KML.10/U)
- Fiber-Optic Link Interface (Module KML.F)
- I/O Module Applications
- Technical System Characteristics
- Chapter 2 Installation
- Introduction
- Site Requirements and Prerequisites
- Input Power Requirements
- Grounding
- Channel Connection Considerations
- Front and Rear Panel Clearance
- Ambient Requirements
- Electromagnetic Compatibility Considerations
- Current and Power Requirements of MX-2100 Power Supply Modules
- Current and Power Capabilities of MX-2100 Power Supply Modules
- Ratings of Ring and Feed Voltage Supplies
- Equipment Needed
- Package Contents
- Installation and Setup of MX-2100
- Interfaces and Connections
- Initial Setup and Configuration
- Chapter 3 Configuring MX-2100
- Chapter 4 Operation
- Chapter 5 Diagnostics
- Appendix A Connection Data
- Appendix B Alarms
- Appendix C SNMP Management
- Appendix D Software Download
- Appendix E Configuration Parameters
- Appendix F Command Set Description
- General
- Commands
- BYE
- CLR ALM
- CLR LOOP
- CLR MONITOR
- CONNECT SWITCH
- DATE
- DEF AGENDA
- DEF AGENT
- DEF ALM DEBOUNCE
- DEF CALL
- DEF CH
- DEF CON
- DEF DB FLIP
- DEF DP
- DEF FRAME
- DEF MANAGER LIST
- DEF ML
- DEF ML CALL
- DEF NAME
- DEF NODE
- DEF NP
- DEF PWD
- DEF ROUTE
- DEF SP
- DEF SYS
- DISCONNECT SWITCH
- DSP AGENT
- DSP ALM
- DSP BERT
- DSP CH CON
- DSP FLIP
- DSP HDR TST
- DSP MANAGER LIST
- DSP KVF5orDSP PBX
- DSP KVF6
- DSP SIGNALINGorDSP SIG
- DSP PRBS_INJ
- DSP REM AGENT
- DSP REV
- DSP ST FRAME
- DSP ST ML
- DSP ST SLOT
- DSP ST SYS
- EDIT DB
- EXIT
- F
- FLIP ML
- HELP
- INIT DB
- INIT F
- LOAD DB 1\2
- LOAD IO
- LOOP
- ML RECOVERY
- MONITOR
- REBUILD FRAME
- RESET LOC
- RESET IO
- RESET ML
- TIME
- UPDATE DB 1\2
- Index
- DC Power Supply Connection

Chapter 2 Installation MX-2100/2104 Installation and Operation Manual
2-4 Site Requirements and Prerequisites
Table 2-1. Power Consumption of MX-2100 Modules
I/O Module +5 VDC
Power
Consumption
[Watts]
+12 VDC
Power
Consumption
[Watts]
-12 VDC
Power
Consumption
[Watts]
KLS.1 0.26 0.36 0.216
KLS.1/NEW 0.25 0.36 0.24
KLS.2 0.41 0.264 0.072
KHS.1 0.8 0.78 0.084
KHS.1/V.35 0.8 0.78 0.12
KHS.2 1.055 0.912 0.084
KHS.703 0.8 – –
KHS.U 2.0 – –
KVC.1/E&M 0.875 – 0.18
KVC.1/FXS 1.15 – 0.396
KVC.1/FXO 0.875 – 0.06
KVC.1M/FXS 1.6 – 0.72
KVC.1M/FXSP 2.45 – 0.84
KVC.1M/FXO 1.05 – 0.3
KVC.1M/E&M 1.5 – 0.36
KVC.1M/FXS/CAN 2.1 – 0.72
KVC.1M/FXSP/CAN 2.95 – 0.84
KVC.1M/FXO/CAN 1.55 – 0.3
KVC.1M/E&M/CAN 2.25 – 0.36
KVC.3/FXO 2.5 – 0.3
KVC.3/E&M 2.5 – 0.24
KVC.3/FXS 3 – 1.2
KVC.3/FXSP 5 – 1.308
KVC.3M/S0 3.1 – 0.25
KVF.3/E&M 2.2 0.12 0.6
KVF.3/FXS 3.1 0.06 0.84
KVF.3/FXSP 3.25 0.12 0.96
KVF.3/FXO 2.3 0.12 0.54
KVF.4/FXS 4 – 0.72
KVF.4/FXSP 7.5 – 1.8
KVF.4/E&M 4.1 – 0.72