Specifications
Table Of Contents
- Preface
- Quick Start Guide
- Table of Contents
- Chapter 1 General Information
- Functional Description
- Physical Description
- Application Considerations
- Basic MX-2100 System
- Redundancy (not for MX-2104)
- Dual Link Operation (not for MX-2104)
- Priority Bumping \(not for MX2104\)
- Switched Backup Operation (not for MX-2104)
- Switch Mode
- System Management
- System Timing Considerations
- DTE Timing (KML.1, KML.2, KML.3, KML.4 and KML.10 Modules)
- External DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- Internal Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- Loopback Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- DCE Timing (KML.7, KML.8, and KML.F Modules)
- Main Link Timing Considerations in Bypassing and Multidrop Configurations
- Data Channel Clock Modes
- Timing Modes of ISDN Channels
- Sub Link Timing
- Main Link Interface Characteristics
- V.35 Interface (Module KML.1)
- RS-232 Interface (Module KML.2)
- V.36/RS-422/RS-530 Interface (Module KML.3)
- X.21 Interface (Module KML.4)
- G.703 Codirectional Interface (Module KML.5)
- Standard DDS CSU/DSU (Module KML.6)
- T1 Link Interface (Module KML.7)
- E1 Link Interface (Module KML.8)
- ISDN "S" Interface (Module KML.10/S)
- ISDN "U" Interface (Module KML.10/U)
- Fiber-Optic Link Interface (Module KML.F)
- I/O Module Applications
- Technical System Characteristics
- Chapter 2 Installation
- Introduction
- Site Requirements and Prerequisites
- Input Power Requirements
- Grounding
- Channel Connection Considerations
- Front and Rear Panel Clearance
- Ambient Requirements
- Electromagnetic Compatibility Considerations
- Current and Power Requirements of MX-2100 Power Supply Modules
- Current and Power Capabilities of MX-2100 Power Supply Modules
- Ratings of Ring and Feed Voltage Supplies
- Equipment Needed
- Package Contents
- Installation and Setup of MX-2100
- Interfaces and Connections
- Initial Setup and Configuration
- Chapter 3 Configuring MX-2100
- Chapter 4 Operation
- Chapter 5 Diagnostics
- Appendix A Connection Data
- Appendix B Alarms
- Appendix C SNMP Management
- Appendix D Software Download
- Appendix E Configuration Parameters
- Appendix F Command Set Description
- General
- Commands
- BYE
- CLR ALM
- CLR LOOP
- CLR MONITOR
- CONNECT SWITCH
- DATE
- DEF AGENDA
- DEF AGENT
- DEF ALM DEBOUNCE
- DEF CALL
- DEF CH
- DEF CON
- DEF DB FLIP
- DEF DP
- DEF FRAME
- DEF MANAGER LIST
- DEF ML
- DEF ML CALL
- DEF NAME
- DEF NODE
- DEF NP
- DEF PWD
- DEF ROUTE
- DEF SP
- DEF SYS
- DISCONNECT SWITCH
- DSP AGENT
- DSP ALM
- DSP BERT
- DSP CH CON
- DSP FLIP
- DSP HDR TST
- DSP MANAGER LIST
- DSP KVF5orDSP PBX
- DSP KVF6
- DSP SIGNALINGorDSP SIG
- DSP PRBS_INJ
- DSP REM AGENT
- DSP REV
- DSP ST FRAME
- DSP ST ML
- DSP ST SLOT
- DSP ST SYS
- EDIT DB
- EXIT
- F
- FLIP ML
- HELP
- INIT DB
- INIT F
- LOAD DB 1\2
- LOAD IO
- LOOP
- ML RECOVERY
- MONITOR
- REBUILD FRAME
- RESET LOC
- RESET IO
- RESET ML
- TIME
- UPDATE DB 1\2
- Index
- DC Power Supply Connection

Chapter 2 Installation MX-2100/2104 Installation and Operation Manual
2-2 Site Requirements and Prerequisites
2.2 Site Requirements and Prerequisites
Input Power Requirements
For AC operation, the MX-2100 unit should be installed within
1.5m (5 feet) of an easily-accessible grounded AC outlet capable of furnishing the
mains voltage of the ordered KPS module. KPS.4 and KPS.6 modules of MX-2100
and the AC power supply of MX-2104 can operate on AC supply voltages in the
range of 100 to 240 VAC, at input frequencies of 47 through 440 Hz. The
maximum input current varies with the input voltage.
For DC operation, the MX-2100 unit should be connected to a -48 VDC or
-24 VDC source (in accordance with the nominal voltage of the ordered KPS
module) through a circuit breaker. The DC source must comply with the
requirements of EN60950.
Grounding
For your protection and to prevent possible damage to equipment when a fault
condition, e.g., lightning stroke or contact with high-voltage power lines,
occurs on the lines connected to the equipment, the case of the MX-2100 unit
must be properly grounded at any time. Any interruption of the protective
(grounding) connection inside or outside the equipment, or the disconnection
of the protective ground terminal can make this equipment dangerous.
Intentional interruption is prohibited.
Before switching on this equipment and before connecting any cables, the
protective ground terminals of the equipment must be connected to a protective
ground. The grounding arrangements depend on the equipment power supply
source:
• AC-powered units: the grounding connection is made through the mains plug,
which must be inserted in a power socket (outlet) with protective ground
contact. Do not negate the protective ground contact by using an extension
cord (power cable) without a protective conductor (grounding).
• DC-powered units: the grounding connection is made through one of the pins
of the DC power connector.
• In addition, all units/PS modules have a grounding terminal: connect it to the
nearest grounding point using a short, wide copper braid (or a thick copper
wire).
Whenever possible, the MX-2100 units should be installed in a properly grounded
rack, connected to a reliable, low-resistance grounding system.
Warning