Specifications
Table Of Contents
- Preface
- Quick Start Guide
- Table of Contents
- Chapter 1 General Information
- Functional Description
- Physical Description
- Application Considerations
- Basic MX-2100 System
- Redundancy (not for MX-2104)
- Dual Link Operation (not for MX-2104)
- Priority Bumping \(not for MX2104\)
- Switched Backup Operation (not for MX-2104)
- Switch Mode
- System Management
- System Timing Considerations
- DTE Timing (KML.1, KML.2, KML.3, KML.4 and KML.10 Modules)
- External DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- Internal Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- Loopback Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- DCE Timing (KML.7, KML.8, and KML.F Modules)
- Main Link Timing Considerations in Bypassing and Multidrop Configurations
- Data Channel Clock Modes
- Timing Modes of ISDN Channels
- Sub Link Timing
- Main Link Interface Characteristics
- V.35 Interface (Module KML.1)
- RS-232 Interface (Module KML.2)
- V.36/RS-422/RS-530 Interface (Module KML.3)
- X.21 Interface (Module KML.4)
- G.703 Codirectional Interface (Module KML.5)
- Standard DDS CSU/DSU (Module KML.6)
- T1 Link Interface (Module KML.7)
- E1 Link Interface (Module KML.8)
- ISDN "S" Interface (Module KML.10/S)
- ISDN "U" Interface (Module KML.10/U)
- Fiber-Optic Link Interface (Module KML.F)
- I/O Module Applications
- Technical System Characteristics
- Chapter 2 Installation
- Introduction
- Site Requirements and Prerequisites
- Input Power Requirements
- Grounding
- Channel Connection Considerations
- Front and Rear Panel Clearance
- Ambient Requirements
- Electromagnetic Compatibility Considerations
- Current and Power Requirements of MX-2100 Power Supply Modules
- Current and Power Capabilities of MX-2100 Power Supply Modules
- Ratings of Ring and Feed Voltage Supplies
- Equipment Needed
- Package Contents
- Installation and Setup of MX-2100
- Interfaces and Connections
- Initial Setup and Configuration
- Chapter 3 Configuring MX-2100
- Chapter 4 Operation
- Chapter 5 Diagnostics
- Appendix A Connection Data
- Appendix B Alarms
- Appendix C SNMP Management
- Appendix D Software Download
- Appendix E Configuration Parameters
- Appendix F Command Set Description
- General
- Commands
- BYE
- CLR ALM
- CLR LOOP
- CLR MONITOR
- CONNECT SWITCH
- DATE
- DEF AGENDA
- DEF AGENT
- DEF ALM DEBOUNCE
- DEF CALL
- DEF CH
- DEF CON
- DEF DB FLIP
- DEF DP
- DEF FRAME
- DEF MANAGER LIST
- DEF ML
- DEF ML CALL
- DEF NAME
- DEF NODE
- DEF NP
- DEF PWD
- DEF ROUTE
- DEF SP
- DEF SYS
- DISCONNECT SWITCH
- DSP AGENT
- DSP ALM
- DSP BERT
- DSP CH CON
- DSP FLIP
- DSP HDR TST
- DSP MANAGER LIST
- DSP KVF5orDSP PBX
- DSP KVF6
- DSP SIGNALINGorDSP SIG
- DSP PRBS_INJ
- DSP REM AGENT
- DSP REV
- DSP ST FRAME
- DSP ST ML
- DSP ST SLOT
- DSP ST SYS
- EDIT DB
- EXIT
- F
- FLIP ML
- HELP
- INIT DB
- INIT F
- LOAD DB 1\2
- LOAD IO
- LOOP
- ML RECOVERY
- MONITOR
- REBUILD FRAME
- RESET LOC
- RESET IO
- RESET ML
- TIME
- UPDATE DB 1\2
- Index
- DC Power Supply Connection

Chapter 1 General Information MX-2100/2104 Installation and Operation Manual
1-48 Application Considerations
V.36/RS-422/RS-530 Interface (Module KML.3)
The RS-530 interface supports all the interface signals specified by EIA RS-530,
with the following exceptions:
• Refer to the notes regarding the RTS, CTS and DSR signals presented for the
V.35 interface.
• The DTR signal is not supported. The line is used as ERC (external receive
clock) output line.
X.21 Interface (Module KML.4)
The X.21 interface provides partial support for interface signals. The signals not
fully supported are as follows:
• The C (control) signal is constantly ON.
• The I (indication) signal is used as follows:
− When the I signal is ON, the interface operates normally.
− When the signal is OFF, MX-2100 sends a continuous MARK (binary "1") on
the main link.
G.703 Codirectional Interface (Module KML.5)
The G.703 codirectional interface complies with all the requirements of ITU-T
Rec. G.703 applicable to codirectional interfaces. This interface supports only data
rates of 64 and 128 kbps.
Standard DDS CSU/DSU (Module KML.6)
The KML.6 main link interface complies with AT&T Pub. 62310: Standard Digital
Data Service (DDS), Channel Interface Specifications. The interface supports data
rates of 9.6, 19.2, and 56 kbps.
T1 Link Interface (Module KML.7)
The KML.7 module supports both the D4 (SF) and ESF framing formats, in
accordance with user's selection. Zero suppression over the line is user-selectable
(transparent (AMI) coding, B7ZS, or B8ZS).
The T1 line interface meets the requirements of AT&T TR-62411, ANSI T1.403,
and ITU-T Rec. G.703, G.704. Jitter performance complies with the requirements
of AT&T TR-62411.
E1 Link Interface (Module KML.8)
The E1 link interface meets the requirements of ITU-T Rec. G.703, G.704, and
G.732, and supports both 256N and 256S multiframes (2 or 16 frames per
multiframe, respectively), in accordance with user's selection. The KML.8 module
also supports the CRC-4 option, including support for the E bit, as specified in
ITU-T Rec. G.704, thereby allowing the carrier to monitor the link to MX-2100.
CRC-4 use is user-programmable.