Specifications
Table Of Contents
- Preface
- Quick Start Guide
- Table of Contents
- Chapter 1 General Information
- Functional Description
- Physical Description
- Application Considerations
- Basic MX-2100 System
- Redundancy (not for MX-2104)
- Dual Link Operation (not for MX-2104)
- Priority Bumping \(not for MX2104\)
- Switched Backup Operation (not for MX-2104)
- Switch Mode
- System Management
- System Timing Considerations
- DTE Timing (KML.1, KML.2, KML.3, KML.4 and KML.10 Modules)
- External DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- Internal Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- Loopback Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- DCE Timing (KML.7, KML.8, and KML.F Modules)
- Main Link Timing Considerations in Bypassing and Multidrop Configurations
- Data Channel Clock Modes
- Timing Modes of ISDN Channels
- Sub Link Timing
- Main Link Interface Characteristics
- V.35 Interface (Module KML.1)
- RS-232 Interface (Module KML.2)
- V.36/RS-422/RS-530 Interface (Module KML.3)
- X.21 Interface (Module KML.4)
- G.703 Codirectional Interface (Module KML.5)
- Standard DDS CSU/DSU (Module KML.6)
- T1 Link Interface (Module KML.7)
- E1 Link Interface (Module KML.8)
- ISDN "S" Interface (Module KML.10/S)
- ISDN "U" Interface (Module KML.10/U)
- Fiber-Optic Link Interface (Module KML.F)
- I/O Module Applications
- Technical System Characteristics
- Chapter 2 Installation
- Introduction
- Site Requirements and Prerequisites
- Input Power Requirements
- Grounding
- Channel Connection Considerations
- Front and Rear Panel Clearance
- Ambient Requirements
- Electromagnetic Compatibility Considerations
- Current and Power Requirements of MX-2100 Power Supply Modules
- Current and Power Capabilities of MX-2100 Power Supply Modules
- Ratings of Ring and Feed Voltage Supplies
- Equipment Needed
- Package Contents
- Installation and Setup of MX-2100
- Interfaces and Connections
- Initial Setup and Configuration
- Chapter 3 Configuring MX-2100
- Chapter 4 Operation
- Chapter 5 Diagnostics
- Appendix A Connection Data
- Appendix B Alarms
- Appendix C SNMP Management
- Appendix D Software Download
- Appendix E Configuration Parameters
- Appendix F Command Set Description
- General
- Commands
- BYE
- CLR ALM
- CLR LOOP
- CLR MONITOR
- CONNECT SWITCH
- DATE
- DEF AGENDA
- DEF AGENT
- DEF ALM DEBOUNCE
- DEF CALL
- DEF CH
- DEF CON
- DEF DB FLIP
- DEF DP
- DEF FRAME
- DEF MANAGER LIST
- DEF ML
- DEF ML CALL
- DEF NAME
- DEF NODE
- DEF NP
- DEF PWD
- DEF ROUTE
- DEF SP
- DEF SYS
- DISCONNECT SWITCH
- DSP AGENT
- DSP ALM
- DSP BERT
- DSP CH CON
- DSP FLIP
- DSP HDR TST
- DSP MANAGER LIST
- DSP KVF5orDSP PBX
- DSP KVF6
- DSP SIGNALINGorDSP SIG
- DSP PRBS_INJ
- DSP REM AGENT
- DSP REV
- DSP ST FRAME
- DSP ST ML
- DSP ST SLOT
- DSP ST SYS
- EDIT DB
- EXIT
- F
- FLIP ML
- HELP
- INIT DB
- INIT F
- LOAD DB 1\2
- LOAD IO
- LOOP
- ML RECOVERY
- MONITOR
- REBUILD FRAME
- RESET LOC
- RESET IO
- RESET ML
- TIME
- UPDATE DB 1\2
- Index
- DC Power Supply Connection

Chapter 1 General Information MX-2100/2104 Installation and Operation Manual
1-46 Application Considerations
When operating channels in the DTE2 clock mode, one of the data channels can
be selected as the external timing reference source for the entire system timing.
The external timing option is always used because it ensures the main link transmit
and receive data rates are locked to the corresponding channel rates. If the main
link data rates are not locked to the corresponding channel rates, bit integrity will
be lost. MX-2100 units integrated in a large network that includes a master timing
reference ensures locked timing without the use of external timing. The master
timing source is used by all the equipment in the network. This includes data
equipment connected to the MX-2100 channels and the transmission equipment
serving the main link. Do not use the DTE2 clock mode when the main link timing
is derived from the internal oscillator of MX-2100.
If you are using a MX-2100 equipped with KML.5, KML.6, KML.7, KML.8,
KML.10, or KML.F modules and you cannot attain the conditions for master timing
as described above, do not use DTE2 clock mode.
MX-2100
External Timing
Digital
Data
Network
Master
Clock
KHS.1
DTE
XMIT Clock XMIT Clock
RCV Clock RCV Clock
Modem Modem
Mode DTE 2
Figure 1-36. Clock Mode 3 (DTE2)
Timing Modes of ISDN Channels
ISDN basic rate access channels are available on the KHS.U and KVF.4/S0
modules. These channels provide the interface between the MX-2100 system and
the ISDN network.
Timing of Channels with "U" Interface
The transmit timing of a channel with "U" interface, such as a KHS.U module, is
locked to the nodal timing of MX-2100. The system nodal timing depends on the
selected operating mode of the channel:
• NT Mode. In the NT mode, the ISDN "U" interfaces are usually connected to
an ISDN switch, whose timing is generally provided by an accurate and stable
source.
One of the "U" interface ports connected to the network termination (NT) unit
must be selected as an external clock source for MX-2100. Thus the MX-2100
nodal clock, and therefore the transmit timing of the "U" interface, are locked
to the timing of the NT unit.
• LT Mode. MX-2100 provides the transmit clock for the "U" interface. The
receive timing is recovered from the signal received from the user's terminal
equipment.