Specifications
Table Of Contents
- Preface
- Quick Start Guide
- Table of Contents
- Chapter 1 General Information
- Functional Description
- Physical Description
- Application Considerations
- Basic MX-2100 System
- Redundancy (not for MX-2104)
- Dual Link Operation (not for MX-2104)
- Priority Bumping \(not for MX2104\)
- Switched Backup Operation (not for MX-2104)
- Switch Mode
- System Management
- System Timing Considerations
- DTE Timing (KML.1, KML.2, KML.3, KML.4 and KML.10 Modules)
- External DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- Internal Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- Loopback Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- DCE Timing (KML.7, KML.8, and KML.F Modules)
- Main Link Timing Considerations in Bypassing and Multidrop Configurations
- Data Channel Clock Modes
- Timing Modes of ISDN Channels
- Sub Link Timing
- Main Link Interface Characteristics
- V.35 Interface (Module KML.1)
- RS-232 Interface (Module KML.2)
- V.36/RS-422/RS-530 Interface (Module KML.3)
- X.21 Interface (Module KML.4)
- G.703 Codirectional Interface (Module KML.5)
- Standard DDS CSU/DSU (Module KML.6)
- T1 Link Interface (Module KML.7)
- E1 Link Interface (Module KML.8)
- ISDN "S" Interface (Module KML.10/S)
- ISDN "U" Interface (Module KML.10/U)
- Fiber-Optic Link Interface (Module KML.F)
- I/O Module Applications
- Technical System Characteristics
- Chapter 2 Installation
- Introduction
- Site Requirements and Prerequisites
- Input Power Requirements
- Grounding
- Channel Connection Considerations
- Front and Rear Panel Clearance
- Ambient Requirements
- Electromagnetic Compatibility Considerations
- Current and Power Requirements of MX-2100 Power Supply Modules
- Current and Power Capabilities of MX-2100 Power Supply Modules
- Ratings of Ring and Feed Voltage Supplies
- Equipment Needed
- Package Contents
- Installation and Setup of MX-2100
- Interfaces and Connections
- Initial Setup and Configuration
- Chapter 3 Configuring MX-2100
- Chapter 4 Operation
- Chapter 5 Diagnostics
- Appendix A Connection Data
- Appendix B Alarms
- Appendix C SNMP Management
- Appendix D Software Download
- Appendix E Configuration Parameters
- Appendix F Command Set Description
- General
- Commands
- BYE
- CLR ALM
- CLR LOOP
- CLR MONITOR
- CONNECT SWITCH
- DATE
- DEF AGENDA
- DEF AGENT
- DEF ALM DEBOUNCE
- DEF CALL
- DEF CH
- DEF CON
- DEF DB FLIP
- DEF DP
- DEF FRAME
- DEF MANAGER LIST
- DEF ML
- DEF ML CALL
- DEF NAME
- DEF NODE
- DEF NP
- DEF PWD
- DEF ROUTE
- DEF SP
- DEF SYS
- DISCONNECT SWITCH
- DSP AGENT
- DSP ALM
- DSP BERT
- DSP CH CON
- DSP FLIP
- DSP HDR TST
- DSP MANAGER LIST
- DSP KVF5orDSP PBX
- DSP KVF6
- DSP SIGNALINGorDSP SIG
- DSP PRBS_INJ
- DSP REM AGENT
- DSP REV
- DSP ST FRAME
- DSP ST ML
- DSP ST SLOT
- DSP ST SYS
- EDIT DB
- EXIT
- F
- FLIP ML
- HELP
- INIT DB
- INIT F
- LOAD DB 1\2
- LOAD IO
- LOOP
- ML RECOVERY
- MONITOR
- REBUILD FRAME
- RESET LOC
- RESET IO
- RESET ML
- TIME
- UPDATE DB 1\2
- Index
- DC Power Supply Connection

MX-2100/2104 Installation and Operation Manual Chapter 1 General Information
Application Considerations 1-41
MX-2100 MX-2100
Modem with
External Timing
E-DCE Timing
(External Source)
DTE Timing
DDS
Network
Master
Clock
Channel
in DTE2
Timing
KHS.1
DTE
XMIT
Clock
RCV
Clock
Modem with
Loopback Timing
Figure 1-28. Typical External DCE Timing Application
• Internal timing. The source for the internal timing signals is a crystal oscillator
located in the KML module. The timing accuracy of this oscillator is ±50 parts
per million (ppm).
The internal timing mode can be used in point-to-point links and in
independent networks. In any system, only one unit may operate with internal
timing. All the other units must use DTE timing to ensure synchronization. In
this way, the unit that operates with internal timing is the source of the master
clock and determines timing of the entire network.
In the external DCE mode, buffers are used in the main link receive path, but not
in the transmit path. Buffer size is selectable, ±8 or ±256 bits.
DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
With DCE timing, MX-2100 provides both the transmit and receive clock signals to
the equipment to which it is connected. The timing reference source of the
transmit timing signals can be selected as for the external DCE mode. The
connected equipment must then use the DTE timing mode.
The DCE timing mode is useful when the MX-2100 main link is connected to a
channel of a corporate data transmission system (e.g., the main link of one of the
MX-2100 units is connected to a data channel of an E1/T1 multiplexer), and one
or more of the MX-2100 channels are connected to a data network which
provides accurate timing (e.g., to a DDS link, an ISDN line, or another data
network). In this case, the network timing can be distributed through MX-2100 to
the other parts of the system. Figure 1-29 shows a typical connection to a DDS
network through a KHS.1 module; for connection to an ISDN line, replace the
KHS.1 module with a KHS.U module.
In the DCE mode, no buffers are used in the main link data paths, because
MX-2100 determines the receive and transmit rates.