Specifications
Table Of Contents
- Preface
- Quick Start Guide
- Table of Contents
- Chapter 1 General Information
- Functional Description
- Physical Description
- Application Considerations
- Basic MX-2100 System
- Redundancy (not for MX-2104)
- Dual Link Operation (not for MX-2104)
- Priority Bumping \(not for MX2104\)
- Switched Backup Operation (not for MX-2104)
- Switch Mode
- System Management
- System Timing Considerations
- DTE Timing (KML.1, KML.2, KML.3, KML.4 and KML.10 Modules)
- External DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- Internal Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- Loopback Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- DCE Timing (KML.7, KML.8, and KML.F Modules)
- Main Link Timing Considerations in Bypassing and Multidrop Configurations
- Data Channel Clock Modes
- Timing Modes of ISDN Channels
- Sub Link Timing
- Main Link Interface Characteristics
- V.35 Interface (Module KML.1)
- RS-232 Interface (Module KML.2)
- V.36/RS-422/RS-530 Interface (Module KML.3)
- X.21 Interface (Module KML.4)
- G.703 Codirectional Interface (Module KML.5)
- Standard DDS CSU/DSU (Module KML.6)
- T1 Link Interface (Module KML.7)
- E1 Link Interface (Module KML.8)
- ISDN "S" Interface (Module KML.10/S)
- ISDN "U" Interface (Module KML.10/U)
- Fiber-Optic Link Interface (Module KML.F)
- I/O Module Applications
- Technical System Characteristics
- Chapter 2 Installation
- Introduction
- Site Requirements and Prerequisites
- Input Power Requirements
- Grounding
- Channel Connection Considerations
- Front and Rear Panel Clearance
- Ambient Requirements
- Electromagnetic Compatibility Considerations
- Current and Power Requirements of MX-2100 Power Supply Modules
- Current and Power Capabilities of MX-2100 Power Supply Modules
- Ratings of Ring and Feed Voltage Supplies
- Equipment Needed
- Package Contents
- Installation and Setup of MX-2100
- Interfaces and Connections
- Initial Setup and Configuration
- Chapter 3 Configuring MX-2100
- Chapter 4 Operation
- Chapter 5 Diagnostics
- Appendix A Connection Data
- Appendix B Alarms
- Appendix C SNMP Management
- Appendix D Software Download
- Appendix E Configuration Parameters
- Appendix F Command Set Description
- General
- Commands
- BYE
- CLR ALM
- CLR LOOP
- CLR MONITOR
- CONNECT SWITCH
- DATE
- DEF AGENDA
- DEF AGENT
- DEF ALM DEBOUNCE
- DEF CALL
- DEF CH
- DEF CON
- DEF DB FLIP
- DEF DP
- DEF FRAME
- DEF MANAGER LIST
- DEF ML
- DEF ML CALL
- DEF NAME
- DEF NODE
- DEF NP
- DEF PWD
- DEF ROUTE
- DEF SP
- DEF SYS
- DISCONNECT SWITCH
- DSP AGENT
- DSP ALM
- DSP BERT
- DSP CH CON
- DSP FLIP
- DSP HDR TST
- DSP MANAGER LIST
- DSP KVF5orDSP PBX
- DSP KVF6
- DSP SIGNALINGorDSP SIG
- DSP PRBS_INJ
- DSP REM AGENT
- DSP REV
- DSP ST FRAME
- DSP ST ML
- DSP ST SLOT
- DSP ST SYS
- EDIT DB
- EXIT
- F
- FLIP ML
- HELP
- INIT DB
- INIT F
- LOAD DB 1\2
- LOAD IO
- LOOP
- ML RECOVERY
- MONITOR
- REBUILD FRAME
- RESET LOC
- RESET IO
- RESET ML
- TIME
- UPDATE DB 1\2
- Index
- DC Power Supply Connection

Chapter 1 General Information MX-2100/2104 Installation and Operation Manual
1-40 Application Considerations
In the leased line configuration (A) of Figure 1-27, two MX-2100 units
communicate through a leased line using two high-speed modems, or other
transmission equipment (e.g., higher-speed digital multiplexers) capable of
supporting the required main link data rate. The modems provide the transmit and
receive clock signals to the MX-2100 units. In this configuration, the modem
connected to one of the MX-2100 units is selected to provide the timing reference
for the whole link, by selecting its INTERNAL timing mode. The other modem is
set to operate in the LOOPBACK timing mode, thereby ensuring that both
MX-2100 units derive their timing reference from the same source.
In the digital configuration (B) of Figure 1-27, two MX-2100 units communicate
through a digital transmission network, e.g., a national or private carrier network,
or an ISDN network (in the latter case, the connection is usually made by means of
KML.10 main link modules).
Digital data and ISDN networks usually incorporate very accurate timing sources,
which are always preferable. In many cases these networks will not accept data at
a rate that differs from their own rate. In the digital configuration, the modems that
connect the MX-2100 units to the digital data network are set to operate in the
LOOPBACK timing mode. This ensures that the two MX-2100 units derive their
timing reference from the accurate master clock provided by the network.
When operating in the DTE timing mode, buffers are used in the receive and
transmit data paths to allow retiming and to absorb short-term timing instabilities.
Buffers size is ±8 bits; when operating over satellite links, the receive buffer size
can be increased to ±256 bits.
External DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
With external DCE timing, MX-2100 provides the main link transmit clock signal to
the modem, and accepts a receive clock signal from the modem. In this timing
mode, it is necessary to specify the transmit timing reference source. Two
reference sources can be used:
• External. The MX-2100 main link transmit timing is synchronized to the
transmit clock of a data module channel. The desired channel is selected by
the operator, and must operate in the DTE2 clock mode.
The external mode is very useful when one or more of the MX-2100 channels
are connected to a AT&T DDS link, or to a similar data network. A typical
configuration with the MX-2100 units connected as a tail-end link for channels
using the DDS network is shown in Figure 1-28.
The DDS network can provide highly accurate timing and will accept only data
with similar accuracy, therefore it is necessary to lock the timing of the
MX-2100 link to the channel timing. This is accomplished by operating the
modem connected to the left MX-2100 in the EXTERNAL timing mode. The
other modem is set to operate in the LOOPBACK timing mode, thereby
ensuring that the right MX-2100 unit derives its timing reference from the
same source.