Specifications
Table Of Contents
- Preface
- Quick Start Guide
- Table of Contents
- Chapter 1 General Information
- Functional Description
- Physical Description
- Application Considerations
- Basic MX-2100 System
- Redundancy (not for MX-2104)
- Dual Link Operation (not for MX-2104)
- Priority Bumping \(not for MX2104\)
- Switched Backup Operation (not for MX-2104)
- Switch Mode
- System Management
- System Timing Considerations
- DTE Timing (KML.1, KML.2, KML.3, KML.4 and KML.10 Modules)
- External DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- Internal Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- Loopback Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- DCE Timing (KML.7, KML.8, and KML.F Modules)
- Main Link Timing Considerations in Bypassing and Multidrop Configurations
- Data Channel Clock Modes
- Timing Modes of ISDN Channels
- Sub Link Timing
- Main Link Interface Characteristics
- V.35 Interface (Module KML.1)
- RS-232 Interface (Module KML.2)
- V.36/RS-422/RS-530 Interface (Module KML.3)
- X.21 Interface (Module KML.4)
- G.703 Codirectional Interface (Module KML.5)
- Standard DDS CSU/DSU (Module KML.6)
- T1 Link Interface (Module KML.7)
- E1 Link Interface (Module KML.8)
- ISDN "S" Interface (Module KML.10/S)
- ISDN "U" Interface (Module KML.10/U)
- Fiber-Optic Link Interface (Module KML.F)
- I/O Module Applications
- Technical System Characteristics
- Chapter 2 Installation
- Introduction
- Site Requirements and Prerequisites
- Input Power Requirements
- Grounding
- Channel Connection Considerations
- Front and Rear Panel Clearance
- Ambient Requirements
- Electromagnetic Compatibility Considerations
- Current and Power Requirements of MX-2100 Power Supply Modules
- Current and Power Capabilities of MX-2100 Power Supply Modules
- Ratings of Ring and Feed Voltage Supplies
- Equipment Needed
- Package Contents
- Installation and Setup of MX-2100
- Interfaces and Connections
- Initial Setup and Configuration
- Chapter 3 Configuring MX-2100
- Chapter 4 Operation
- Chapter 5 Diagnostics
- Appendix A Connection Data
- Appendix B Alarms
- Appendix C SNMP Management
- Appendix D Software Download
- Appendix E Configuration Parameters
- Appendix F Command Set Description
- General
- Commands
- BYE
- CLR ALM
- CLR LOOP
- CLR MONITOR
- CONNECT SWITCH
- DATE
- DEF AGENDA
- DEF AGENT
- DEF ALM DEBOUNCE
- DEF CALL
- DEF CH
- DEF CON
- DEF DB FLIP
- DEF DP
- DEF FRAME
- DEF MANAGER LIST
- DEF ML
- DEF ML CALL
- DEF NAME
- DEF NODE
- DEF NP
- DEF PWD
- DEF ROUTE
- DEF SP
- DEF SYS
- DISCONNECT SWITCH
- DSP AGENT
- DSP ALM
- DSP BERT
- DSP CH CON
- DSP FLIP
- DSP HDR TST
- DSP MANAGER LIST
- DSP KVF5orDSP PBX
- DSP KVF6
- DSP SIGNALINGorDSP SIG
- DSP PRBS_INJ
- DSP REM AGENT
- DSP REV
- DSP ST FRAME
- DSP ST ML
- DSP ST SLOT
- DSP ST SYS
- EDIT DB
- EXIT
- F
- FLIP ML
- HELP
- INIT DB
- INIT F
- LOAD DB 1\2
- LOAD IO
- LOOP
- ML RECOVERY
- MONITOR
- REBUILD FRAME
- RESET LOC
- RESET IO
- RESET ML
- TIME
- UPDATE DB 1\2
- Index
- DC Power Supply Connection

MX-2100/2104 Installation and Operation Manual Chapter 1 General Information
Application Considerations 1-37
• There is no indication for the remote loss of frame synchronization, or for the
loops connected at the remote end of the link.
• Remote channel loops are activated on the local channel, therefore such loops
return data toward the remote MX-2100.
• It is not possible to simultaneously activate local and remote loops.
• To perform channel tests by tone injection (voice channels) or pseudo-random
sequence transmission test (data channels), it is necessary to activate a local
main link loop, or to make an appropriate loopback connection at the remote
end of the link.
Management Communication Port
MX-2100 is available with a Supervisory Port Connector (Control port) and with
one of the following three Management Port interfaces on the KCL.2 module:
• MNG: 9-pin Dial Port
• ETHERNET: UTP Ethernet interface
• ETHERNET: BNC Ethernet interface.
Supervisory Port Connector
The 9-pin D-type female type connector located on the KCL.2 module (the
Supervisory Port connector) can be used to manage the MX-2100 unit by means of
an ASCII terminal, a network management station, or TELNET over SLIP. The
communication parameters of this port can be selected in accordance with system
requirements:
• Data rate - 9.6 - for use with ASCII terminal or SLIP connection
- 19.2, 38.4 or 57.6 kbps - for use with SLIP connection only.
• Word format - One start bit
- Seven or eight data bits
- Even, odd or no parity
- One stop bit.
• Interface type - DCE or DTE (user selectable).
Ethernet Port
The KCL.2 module can be ordered with either a UTP or a BNC Ethernet
connector.
Dial Port Connector
The KCL module can be ordered with an additional, 9-pin D-type female type
connector as the MNG port.
This port is intended for connection to a Hayes or Hayes-compatible dial-up
modem. The reporting method can be programmed by the user, in accordance
with the following options:
• Always send a report whenever a new alarm or event condition is detected
• Reporting disabled (no dial-out function).