Specifications
Table Of Contents
- Preface
- Quick Start Guide
- Table of Contents
- Chapter 1 General Information
- Functional Description
- Physical Description
- Application Considerations
- Basic MX-2100 System
- Redundancy (not for MX-2104)
- Dual Link Operation (not for MX-2104)
- Priority Bumping \(not for MX2104\)
- Switched Backup Operation (not for MX-2104)
- Switch Mode
- System Management
- System Timing Considerations
- DTE Timing (KML.1, KML.2, KML.3, KML.4 and KML.10 Modules)
- External DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- Internal Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- Loopback Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- DCE Timing (KML.7, KML.8, and KML.F Modules)
- Main Link Timing Considerations in Bypassing and Multidrop Configurations
- Data Channel Clock Modes
- Timing Modes of ISDN Channels
- Sub Link Timing
- Main Link Interface Characteristics
- V.35 Interface (Module KML.1)
- RS-232 Interface (Module KML.2)
- V.36/RS-422/RS-530 Interface (Module KML.3)
- X.21 Interface (Module KML.4)
- G.703 Codirectional Interface (Module KML.5)
- Standard DDS CSU/DSU (Module KML.6)
- T1 Link Interface (Module KML.7)
- E1 Link Interface (Module KML.8)
- ISDN "S" Interface (Module KML.10/S)
- ISDN "U" Interface (Module KML.10/U)
- Fiber-Optic Link Interface (Module KML.F)
- I/O Module Applications
- Technical System Characteristics
- Chapter 2 Installation
- Introduction
- Site Requirements and Prerequisites
- Input Power Requirements
- Grounding
- Channel Connection Considerations
- Front and Rear Panel Clearance
- Ambient Requirements
- Electromagnetic Compatibility Considerations
- Current and Power Requirements of MX-2100 Power Supply Modules
- Current and Power Capabilities of MX-2100 Power Supply Modules
- Ratings of Ring and Feed Voltage Supplies
- Equipment Needed
- Package Contents
- Installation and Setup of MX-2100
- Interfaces and Connections
- Initial Setup and Configuration
- Chapter 3 Configuring MX-2100
- Chapter 4 Operation
- Chapter 5 Diagnostics
- Appendix A Connection Data
- Appendix B Alarms
- Appendix C SNMP Management
- Appendix D Software Download
- Appendix E Configuration Parameters
- Appendix F Command Set Description
- General
- Commands
- BYE
- CLR ALM
- CLR LOOP
- CLR MONITOR
- CONNECT SWITCH
- DATE
- DEF AGENDA
- DEF AGENT
- DEF ALM DEBOUNCE
- DEF CALL
- DEF CH
- DEF CON
- DEF DB FLIP
- DEF DP
- DEF FRAME
- DEF MANAGER LIST
- DEF ML
- DEF ML CALL
- DEF NAME
- DEF NODE
- DEF NP
- DEF PWD
- DEF ROUTE
- DEF SP
- DEF SYS
- DISCONNECT SWITCH
- DSP AGENT
- DSP ALM
- DSP BERT
- DSP CH CON
- DSP FLIP
- DSP HDR TST
- DSP MANAGER LIST
- DSP KVF5orDSP PBX
- DSP KVF6
- DSP SIGNALINGorDSP SIG
- DSP PRBS_INJ
- DSP REM AGENT
- DSP REV
- DSP ST FRAME
- DSP ST ML
- DSP ST SLOT
- DSP ST SYS
- EDIT DB
- EXIT
- F
- FLIP ML
- HELP
- INIT DB
- INIT F
- LOAD DB 1\2
- LOAD IO
- LOOP
- ML RECOVERY
- MONITOR
- REBUILD FRAME
- RESET LOC
- RESET IO
- RESET ML
- TIME
- UPDATE DB 1\2
- Index
- DC Power Supply Connection

MX-2100/2104 Installation and Operation Manual Chapter 1 General Information
Physical Description 1-11
KML.10 - ISDN main link interface module. The module can be ordered in two
versions:
• KML.10/S with ISDN S-type interface. The "S" interface operates as Terminal
Adapter (TE side), intended for connection to standard Network Termination
(NT) unit.
• KML.10/U with ISDN U-type interface. The "U" interface operates as Network
Termination (NT side) unit, intended for connection to standard Line
Termination (LT) unit.
KML.F - Fiber-optic main link interface module (not for MX-2104). The module
can be ordered with various types of optical interfaces (laser or LED transmitters
for single-mode and multi-mode fiber-optic cable).
For more information, see each main link module’s Installation and Operation
Manual.
Power Supply Modules
The MX-2100 enclosure can accept one or two KPS type power supply modules.
Several types of power supply modules are available:
KPS.3 - 25W power supply module for -48 VDC power
KPS.4 - 50W power supply module for 100 to 240 VAC mains
KPS.5 - 25W power supply module for -24 VDC power
KPS.6 - 56W power supply module for 100 to 240 VAC mains
KPS.7 - 56W power supply module for -48 VDC mains.
Two KPS modules are necessary for redundancy: when both modules are
operational, they share the load, whereas in case of failure or loss of input power
the remaining module continues to supply the power alone and there is no
redundancy. Switch-over is automatic and does not disturb normal operation.
The MX-2104 enclosure includes one power supply. The available types are:
• AC - 30W power supply for 100 to 240 VAC mains
• 48 - 40W power supply for -48 VDC mains.
In addition to power supply modules, the MX-2100 enclosure supports one
KM-Ringer module, for providing line feed and ring voltages for voice channels
and phantom feed for ISDN lines. This module is available in AC (115 to 230 VAC)
and DC (-24 VDC or -48 VDC) input voltage versions. The KM-Ringer can be
installed as a plug-in module for MX-2100, or located on shelves or desktops.