Specifications
Table Of Contents
- Preface
- Quick Start Guide
- Table of Contents
- Chapter 1 General Information
- Functional Description
- Physical Description
- Application Considerations
- Basic MX-2100 System
- Redundancy (not for MX-2104)
- Dual Link Operation (not for MX-2104)
- Priority Bumping \(not for MX2104\)
- Switched Backup Operation (not for MX-2104)
- Switch Mode
- System Management
- System Timing Considerations
- DTE Timing (KML.1, KML.2, KML.3, KML.4 and KML.10 Modules)
- External DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- Internal Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- Loopback Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- DCE Timing (KML.7, KML.8, and KML.F Modules)
- Main Link Timing Considerations in Bypassing and Multidrop Configurations
- Data Channel Clock Modes
- Timing Modes of ISDN Channels
- Sub Link Timing
- Main Link Interface Characteristics
- V.35 Interface (Module KML.1)
- RS-232 Interface (Module KML.2)
- V.36/RS-422/RS-530 Interface (Module KML.3)
- X.21 Interface (Module KML.4)
- G.703 Codirectional Interface (Module KML.5)
- Standard DDS CSU/DSU (Module KML.6)
- T1 Link Interface (Module KML.7)
- E1 Link Interface (Module KML.8)
- ISDN "S" Interface (Module KML.10/S)
- ISDN "U" Interface (Module KML.10/U)
- Fiber-Optic Link Interface (Module KML.F)
- I/O Module Applications
- Technical System Characteristics
- Chapter 2 Installation
- Introduction
- Site Requirements and Prerequisites
- Input Power Requirements
- Grounding
- Channel Connection Considerations
- Front and Rear Panel Clearance
- Ambient Requirements
- Electromagnetic Compatibility Considerations
- Current and Power Requirements of MX-2100 Power Supply Modules
- Current and Power Capabilities of MX-2100 Power Supply Modules
- Ratings of Ring and Feed Voltage Supplies
- Equipment Needed
- Package Contents
- Installation and Setup of MX-2100
- Interfaces and Connections
- Initial Setup and Configuration
- Chapter 3 Configuring MX-2100
- Chapter 4 Operation
- Chapter 5 Diagnostics
- Appendix A Connection Data
- Appendix B Alarms
- Appendix C SNMP Management
- Appendix D Software Download
- Appendix E Configuration Parameters
- Appendix F Command Set Description
- General
- Commands
- BYE
- CLR ALM
- CLR LOOP
- CLR MONITOR
- CONNECT SWITCH
- DATE
- DEF AGENDA
- DEF AGENT
- DEF ALM DEBOUNCE
- DEF CALL
- DEF CH
- DEF CON
- DEF DB FLIP
- DEF DP
- DEF FRAME
- DEF MANAGER LIST
- DEF ML
- DEF ML CALL
- DEF NAME
- DEF NODE
- DEF NP
- DEF PWD
- DEF ROUTE
- DEF SP
- DEF SYS
- DISCONNECT SWITCH
- DSP AGENT
- DSP ALM
- DSP BERT
- DSP CH CON
- DSP FLIP
- DSP HDR TST
- DSP MANAGER LIST
- DSP KVF5orDSP PBX
- DSP KVF6
- DSP SIGNALINGorDSP SIG
- DSP PRBS_INJ
- DSP REM AGENT
- DSP REV
- DSP ST FRAME
- DSP ST ML
- DSP ST SLOT
- DSP ST SYS
- EDIT DB
- EXIT
- F
- FLIP ML
- HELP
- INIT DB
- INIT F
- LOAD DB 1\2
- LOAD IO
- LOOP
- ML RECOVERY
- MONITOR
- REBUILD FRAME
- RESET LOC
- RESET IO
- RESET ML
- TIME
- UPDATE DB 1\2
- Index
- DC Power Supply Connection

Chapter 1 General Information MX-2100/2104 Installation and Operation Manual
1-10 Physical Description
MX-2104 Front Panel
The following figure shows the front panel of the MX-2104 enclosure. The front
panel includes an LCD, three push-buttons, and status indicators. Refer to the
Operation chapter for a description of the front panel functions.
CURSOR SCROLL ENTER
REM
TEST
LOC
RX
TX
ON
LINE
ALARM
LOS
Figure 1-8. MX-2104 Enclosure Front Panel
Common Logic Modules
The MX enclosure requires one KCL.2 type common logic module. The main
functions of the KCL.2 module are control of:
• Multiplexing/demultiplexing operations
• System management
• Interfacing with the optional external system management.
The KCL.2 module stores the MX-2100 database in non-volatile memory
(NVRAM). The configuration information stored in the NVRAM is downloaded to
the module installed in MX-2100 upon turn-on or after system reset. Therefore,
during troubleshooting activities, it is possible to temporarily remove the KCL.2
module from the MX-2100 enclosure without disrupting system operation. If it is
necessary to replace the KCL.2 module, the database can be transferred to a new
module by installing the NVRAM taken from the original module in the
replacement module.
Main Link Modules
The enclosure can accept one KML type main link interface module or, for
MX-2100, two KML type main link interface modules. In addition to main link
interfacing, the KML module performs the multiplexing and demultiplexing
functions and provides the timing signals used by the other modules installed in
the enclosure. Two KML modules are necessary for dual link configurations and for
main link redundancy.
The following main link interface modules are available:
KML.1 - V.35 main link interface module
KML.2 - V.24/RS-232 main link interface module
KML.3 - V.36/RS-422/RS-530 main link interface module
KML.4 - X.21 main link interface module
KML.5 - G.703 codirectional main link interface module
KML.6 - Standard DDS CSU/DSU main link interface module
KML.7 - T1 main link interface module
KML.8 - E1 main link interface module.