Specifications
Table Of Contents
- Preface
- Quick Start Guide
- Table of Contents
- Chapter 1 General Information
- Functional Description
- Physical Description
- Application Considerations
- Basic MX-2100 System
- Redundancy (not for MX-2104)
- Dual Link Operation (not for MX-2104)
- Priority Bumping \(not for MX2104\)
- Switched Backup Operation (not for MX-2104)
- Switch Mode
- System Management
- System Timing Considerations
- DTE Timing (KML.1, KML.2, KML.3, KML.4 and KML.10 Modules)
- External DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- Internal Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- Loopback Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- DCE Timing (KML.7, KML.8, and KML.F Modules)
- Main Link Timing Considerations in Bypassing and Multidrop Configurations
- Data Channel Clock Modes
- Timing Modes of ISDN Channels
- Sub Link Timing
- Main Link Interface Characteristics
- V.35 Interface (Module KML.1)
- RS-232 Interface (Module KML.2)
- V.36/RS-422/RS-530 Interface (Module KML.3)
- X.21 Interface (Module KML.4)
- G.703 Codirectional Interface (Module KML.5)
- Standard DDS CSU/DSU (Module KML.6)
- T1 Link Interface (Module KML.7)
- E1 Link Interface (Module KML.8)
- ISDN "S" Interface (Module KML.10/S)
- ISDN "U" Interface (Module KML.10/U)
- Fiber-Optic Link Interface (Module KML.F)
- I/O Module Applications
- Technical System Characteristics
- Chapter 2 Installation
- Introduction
- Site Requirements and Prerequisites
- Input Power Requirements
- Grounding
- Channel Connection Considerations
- Front and Rear Panel Clearance
- Ambient Requirements
- Electromagnetic Compatibility Considerations
- Current and Power Requirements of MX-2100 Power Supply Modules
- Current and Power Capabilities of MX-2100 Power Supply Modules
- Ratings of Ring and Feed Voltage Supplies
- Equipment Needed
- Package Contents
- Installation and Setup of MX-2100
- Interfaces and Connections
- Initial Setup and Configuration
- Chapter 3 Configuring MX-2100
- Chapter 4 Operation
- Chapter 5 Diagnostics
- Appendix A Connection Data
- Appendix B Alarms
- Appendix C SNMP Management
- Appendix D Software Download
- Appendix E Configuration Parameters
- Appendix F Command Set Description
- General
- Commands
- BYE
- CLR ALM
- CLR LOOP
- CLR MONITOR
- CONNECT SWITCH
- DATE
- DEF AGENDA
- DEF AGENT
- DEF ALM DEBOUNCE
- DEF CALL
- DEF CH
- DEF CON
- DEF DB FLIP
- DEF DP
- DEF FRAME
- DEF MANAGER LIST
- DEF ML
- DEF ML CALL
- DEF NAME
- DEF NODE
- DEF NP
- DEF PWD
- DEF ROUTE
- DEF SP
- DEF SYS
- DISCONNECT SWITCH
- DSP AGENT
- DSP ALM
- DSP BERT
- DSP CH CON
- DSP FLIP
- DSP HDR TST
- DSP MANAGER LIST
- DSP KVF5orDSP PBX
- DSP KVF6
- DSP SIGNALINGorDSP SIG
- DSP PRBS_INJ
- DSP REM AGENT
- DSP REV
- DSP ST FRAME
- DSP ST ML
- DSP ST SLOT
- DSP ST SYS
- EDIT DB
- EXIT
- F
- FLIP ML
- HELP
- INIT DB
- INIT F
- LOAD DB 1\2
- LOAD IO
- LOOP
- ML RECOVERY
- MONITOR
- REBUILD FRAME
- RESET LOC
- RESET IO
- RESET ML
- TIME
- UPDATE DB 1\2
- Index
- DC Power Supply Connection

Chapter 1 General Information MX-2100/2104 Installation and Operation Manual
1-8 Physical Description
Slot 1
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
System Slots I/O Slots
1
PS-A
2
PS-B
3
ML-AKPS
KML.1
4
ML-B
5
CL
6
OP
7
I/O1
8
I/O2
9
I/O3
10
I/O4
11
I/O5
12
I/O6
13
I/O7
14
I/O8
15
I/O9
16
I/O10
17
I/O11
18
I/O12
POWER
Power
Supply
Redundant
Power
Supply
(Optional)
KML
Module
Redundant
KML Module
(Optional)
KCL
Module
Options
Module
Power Supply
Sub-system
Main Link Interface
Sub-system
I/O Modules
as Required
KCL.2
TEST
ALARM
ALM RLY
RESET
Figure 1-4. MX-2100 Enclosure, Rear View
MX-2100 Front Panel
The front panel of the MX-2100 enclosure includes an LCD, three push-buttons,
and labels for the show-through areas for the status indicators located on each
system module. Note that the indicators are arranged in groups (one group for
each system module), that are positioned before the corresponding module slot.
Figure 1-5 shows the front panel of the MX-2100 enclosure. Refer to the Operation
chapter for a description of the front panel functions.
TXD
RXD
RTSM-LEAD
E-LEAD DCD
DATAVOICE
CHANNEL
CURSOR SCROLL ENTER
ALARM
TEST
SYSTEM
ON LINE
TXD
RXD
LOCAL LOS
REMOTE LOS
B
A
MAIN LINK
BA
POWER SUPPLY
STATUS
ON LINE
Figure 1-5. MX-2100 Enclosure Front Panel
MX-2104, General Description
The MX-2104 system consists of a 19" 1U enclosure with 4 slots for the installation
of I/O modules. All the modules are inserted through the rear panel. The cable
connections are also made through the rear panel. The front panel includes a
control section with three push-buttons and a two-row LCD display
(16 characters per row), and status and alarm indicators.
The following figure shows a general view of a MX-2104 enclosure.