Specifications
Table Of Contents
- Preface
- Quick Start Guide
- Table of Contents
- Chapter 1 General Information
- Functional Description
- Physical Description
- Application Considerations
- Basic MX-2100 System
- Redundancy (not for MX-2104)
- Dual Link Operation (not for MX-2104)
- Priority Bumping \(not for MX2104\)
- Switched Backup Operation (not for MX-2104)
- Switch Mode
- System Management
- System Timing Considerations
- DTE Timing (KML.1, KML.2, KML.3, KML.4 and KML.10 Modules)
- External DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- Internal Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- Loopback Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- DCE Timing (KML.7, KML.8, and KML.F Modules)
- Main Link Timing Considerations in Bypassing and Multidrop Configurations
- Data Channel Clock Modes
- Timing Modes of ISDN Channels
- Sub Link Timing
- Main Link Interface Characteristics
- V.35 Interface (Module KML.1)
- RS-232 Interface (Module KML.2)
- V.36/RS-422/RS-530 Interface (Module KML.3)
- X.21 Interface (Module KML.4)
- G.703 Codirectional Interface (Module KML.5)
- Standard DDS CSU/DSU (Module KML.6)
- T1 Link Interface (Module KML.7)
- E1 Link Interface (Module KML.8)
- ISDN "S" Interface (Module KML.10/S)
- ISDN "U" Interface (Module KML.10/U)
- Fiber-Optic Link Interface (Module KML.F)
- I/O Module Applications
- Technical System Characteristics
- Chapter 2 Installation
- Introduction
- Site Requirements and Prerequisites
- Input Power Requirements
- Grounding
- Channel Connection Considerations
- Front and Rear Panel Clearance
- Ambient Requirements
- Electromagnetic Compatibility Considerations
- Current and Power Requirements of MX-2100 Power Supply Modules
- Current and Power Capabilities of MX-2100 Power Supply Modules
- Ratings of Ring and Feed Voltage Supplies
- Equipment Needed
- Package Contents
- Installation and Setup of MX-2100
- Interfaces and Connections
- Initial Setup and Configuration
- Chapter 3 Configuring MX-2100
- Chapter 4 Operation
- Chapter 5 Diagnostics
- Appendix A Connection Data
- Appendix B Alarms
- Appendix C SNMP Management
- Appendix D Software Download
- Appendix E Configuration Parameters
- Appendix F Command Set Description
- General
- Commands
- BYE
- CLR ALM
- CLR LOOP
- CLR MONITOR
- CONNECT SWITCH
- DATE
- DEF AGENDA
- DEF AGENT
- DEF ALM DEBOUNCE
- DEF CALL
- DEF CH
- DEF CON
- DEF DB FLIP
- DEF DP
- DEF FRAME
- DEF MANAGER LIST
- DEF ML
- DEF ML CALL
- DEF NAME
- DEF NODE
- DEF NP
- DEF PWD
- DEF ROUTE
- DEF SP
- DEF SYS
- DISCONNECT SWITCH
- DSP AGENT
- DSP ALM
- DSP BERT
- DSP CH CON
- DSP FLIP
- DSP HDR TST
- DSP MANAGER LIST
- DSP KVF5orDSP PBX
- DSP KVF6
- DSP SIGNALINGorDSP SIG
- DSP PRBS_INJ
- DSP REM AGENT
- DSP REV
- DSP ST FRAME
- DSP ST ML
- DSP ST SLOT
- DSP ST SYS
- EDIT DB
- EXIT
- F
- FLIP ML
- HELP
- INIT DB
- INIT F
- LOAD DB 1\2
- LOAD IO
- LOOP
- ML RECOVERY
- MONITOR
- REBUILD FRAME
- RESET LOC
- RESET IO
- RESET ML
- TIME
- UPDATE DB 1\2
- Index
- DC Power Supply Connection

MX-2100/2104 Installation and Operation Manual Appendix F Command Set Description
Commands F-49
NAME = [mux name]
LAST RESET = [date and time of last reset on KCL.2]
ON LINE DATABASE = 1
NODAL CLOCK = ML
ACTIVE ML = ML-A
ACTIVE ML TIMING = DTE
ML MODE = SINGLE
MONITOR = NONE
ALARM RELAY = ON
INSTALLED MODULES:
ML/IO: ML-A ML-B OPTION 1 2 3
DB: ML --- --- --- KLS.1/N ---
HW: ML.1 --- --- --- KLS.1/N ---
IO: 4 5 6 7 8 9
DB: --- KVF.5/E1/M --- --- --- KVF.4/S0
HW: --- KVF.5/E1/M --- --- --- KVF.4/S0
IO: 10 11 12
DB: --- --- ---
HW: --- --- ---
TIME:08:14:34 DATE:Mon Jun,08,1998
The display fields are as follows:
• NAME - Lists the logical name assigned to MX-2100.
• LAST RESET - Displays the date and time of the last reset on KCL.2.
• ON LINE DATABASE - Indicates the number of the active database:
1 or 2.
• NODAL CLOCK - Indicates the source for the link transmit clock: the internal
oscillator, a module channel, or the main link (ML). ML can only appear when
the main link timing mode is DTE. Refer to the Configuration Parameters
appendix for additional information.
• ACTIVE ML - Indicates the currently-active KML module(s): ML-A for the KML
module installed in slot 3, and/or ML-B for the module installed in slot 4, or
BOTH for a MX-2100 operating in the dual link, priority bumping or switched
backup mode.
• ACTIVE ML TIMING - Source clock of the agent.
• ML MODE - Indicates the current main link mode: SINGLE, REDUNDANCY,
DUAL LINK, PRI_BMP, SW_BACK.
• MONITOR - Indicates the module channel monitored by means of the
MX-2100 front panel indicators, or NONE.
• ALARM RELAY - Indicates the status of MX-2100 alarm relay contacts: ON or
OFF.
• INSTALLED MODULES - Lists, for each slot, the installed module and the
module programmed in the database.