Specifications

Table Of Contents
MX-2100/2104 Installation and Operation Manual Appendix F Command Set Description
Commands F-39
The fields appearing on the data form are as follows:
SLOT - Displays the slot in which each module of the group is installed.
CARD TYPE - Displays the module type installed in the corresponding slot:
KVF5/T1/M or KVF5/T1/S for KVF.5 modules for T1, KVF5/E1/M or KVF5/E1/S
for KVF.5 modules for E1 interface.
TS_GROUP - Group of time slots served by the module installed in the
corresponding slot.
FROM_PBX - Signaling to be transferred through the MX-2100s.
TO_PBX - Signaling to be transmitted to the PBX.
CCS - If the selected signaling mode is CCS (from and to PBX), then this field
will indicate which time slot will carry the CCS information.
ABCD - If the selected signaling mode is CAS (any bits selected except CCS),
then the default A,B,C,D to be transmitted to the PBX is displayed in this field.
POLARITY - Polarity of a bit, Normal/Inverted (for master module only).
For the slave modules, displays N/A.
EXIST - Indicates whether the module includes a sub interface.
DSP KVF6
Purpose
Display the configuration parameters of the KVF.6 modules in the MX-2100.
Format
DSP KVF6
Use
Type:
DSP KVF6 <ENTER>
Typical data for E1/T1 cards is shown as follows:
IO SLOT CARD_TYPE FRAME SIG_MODE TS A B C D EXIST
3 KVF6/T1/24 SF(D4) CAS N/A A B N/A N/A YES
6 KVF6/E1/16 G.732S CAS N/A A B A B NO
7 KVF6/T1/12 ESF CAS N/A A OT_A O 1 YES
8 KVF6/E1/31 G.732N CAS 5 N/A N/A N/A N/A YES
The fields appearing on the data form are as follows:
SLOT - Displays the slot in which each module of KVF.6 is installed.
CARD_TYPE - Displays the module type installed in the corresponding slot:
KVF.6/T1/24, KVF.6/T1/12, KVF.6/E1/31, or KVF.6/E1/16.