Specifications
Table Of Contents
- Preface
- Quick Start Guide
- Table of Contents
- Chapter 1 General Information
- Functional Description
- Physical Description
- Application Considerations
- Basic MX-2100 System
- Redundancy (not for MX-2104)
- Dual Link Operation (not for MX-2104)
- Priority Bumping \(not for MX2104\)
- Switched Backup Operation (not for MX-2104)
- Switch Mode
- System Management
- System Timing Considerations
- DTE Timing (KML.1, KML.2, KML.3, KML.4 and KML.10 Modules)
- External DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- Internal Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- Loopback Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- DCE Timing (KML.7, KML.8, and KML.F Modules)
- Main Link Timing Considerations in Bypassing and Multidrop Configurations
- Data Channel Clock Modes
- Timing Modes of ISDN Channels
- Sub Link Timing
- Main Link Interface Characteristics
- V.35 Interface (Module KML.1)
- RS-232 Interface (Module KML.2)
- V.36/RS-422/RS-530 Interface (Module KML.3)
- X.21 Interface (Module KML.4)
- G.703 Codirectional Interface (Module KML.5)
- Standard DDS CSU/DSU (Module KML.6)
- T1 Link Interface (Module KML.7)
- E1 Link Interface (Module KML.8)
- ISDN "S" Interface (Module KML.10/S)
- ISDN "U" Interface (Module KML.10/U)
- Fiber-Optic Link Interface (Module KML.F)
- I/O Module Applications
- Technical System Characteristics
- Chapter 2 Installation
- Introduction
- Site Requirements and Prerequisites
- Input Power Requirements
- Grounding
- Channel Connection Considerations
- Front and Rear Panel Clearance
- Ambient Requirements
- Electromagnetic Compatibility Considerations
- Current and Power Requirements of MX-2100 Power Supply Modules
- Current and Power Capabilities of MX-2100 Power Supply Modules
- Ratings of Ring and Feed Voltage Supplies
- Equipment Needed
- Package Contents
- Installation and Setup of MX-2100
- Interfaces and Connections
- Initial Setup and Configuration
- Chapter 3 Configuring MX-2100
- Chapter 4 Operation
- Chapter 5 Diagnostics
- Appendix A Connection Data
- Appendix B Alarms
- Appendix C SNMP Management
- Appendix D Software Download
- Appendix E Configuration Parameters
- Appendix F Command Set Description
- General
- Commands
- BYE
- CLR ALM
- CLR LOOP
- CLR MONITOR
- CONNECT SWITCH
- DATE
- DEF AGENDA
- DEF AGENT
- DEF ALM DEBOUNCE
- DEF CALL
- DEF CH
- DEF CON
- DEF DB FLIP
- DEF DP
- DEF FRAME
- DEF MANAGER LIST
- DEF ML
- DEF ML CALL
- DEF NAME
- DEF NODE
- DEF NP
- DEF PWD
- DEF ROUTE
- DEF SP
- DEF SYS
- DISCONNECT SWITCH
- DSP AGENT
- DSP ALM
- DSP BERT
- DSP CH CON
- DSP FLIP
- DSP HDR TST
- DSP MANAGER LIST
- DSP KVF5orDSP PBX
- DSP KVF6
- DSP SIGNALINGorDSP SIG
- DSP PRBS_INJ
- DSP REM AGENT
- DSP REV
- DSP ST FRAME
- DSP ST ML
- DSP ST SLOT
- DSP ST SYS
- EDIT DB
- EXIT
- F
- FLIP ML
- HELP
- INIT DB
- INIT F
- LOAD DB 1\2
- LOAD IO
- LOOP
- ML RECOVERY
- MONITOR
- REBUILD FRAME
- RESET LOC
- RESET IO
- RESET ML
- TIME
- UPDATE DB 1\2
- Index
- DC Power Supply Connection

MX-2100/2104 Installation and Operation Manual Appendix F Command Set Description
Commands F-29
Table F-4. Terminal Programmed Parameters (Cont.)
Designation Function Values
PWD Controls password protection. YES – Password is protected.
NO – Password is not protected.
LOG_OFF Controls the idle disconnect time: NO - Automatic session disconnection disabled.
10_MIN - Automatic disconnection after ten minutes if
no input data is received by the MX-2100 supervisory
port.
DSR - ON The DSR line is continuously on. It
will switch to OFF for five seconds
after the DTR line is switched OFF.
=DTR - The DSR line tracks the DTR line. When
INTERFACE=DTE, the DSR line will switch to ON for
five seconds when the RI line is ON while the DTR line
is OFF.
POP_ALM Controls the automatic display of
alarms on the terminal.
YES - The terminal automatically displays every 10
minutes the alarm status (or whenever a new ON
alarm is received, or an ON/OFF alarm changes state
from OFF to ON.
NO - The automatic display feature is disabled.
AUXILIARY-DEVICE Selects the management mode
supported by the Control port:
Note: At any time, only one of the
two ports of the KCL.2 module can be
used for management access.
NONE - Control port is not operational.
TERMINAL - Control port supports only management
by means of a supervision terminal.
NMS SLIP - The Control port connects to an SNMP
management station and/or TELNET host using the
SLIP protocol.
AGENT SLIP - The network port is connected to
another agent port using the SLIP protocol.
NMS PPP - Same as NMS SLIP, except the PPP
protocol is used.
AGENT PPP - Same as AGENT SLIP, except the PPP
protocol is used.
Note: The SLIP and PPP selections are supported only
when the Control port interface (selected by means of
the internal KCL.2 switches).
DEF SYS
Purpose
Assign values to system parameters.
Format
DEF SYS
Use
1. To define system parameters, type:
DEF SYS <ENTER>