Specifications
Table Of Contents
- Preface
- Quick Start Guide
- Table of Contents
- Chapter 1 General Information
- Functional Description
- Physical Description
- Application Considerations
- Basic MX-2100 System
- Redundancy (not for MX-2104)
- Dual Link Operation (not for MX-2104)
- Priority Bumping \(not for MX2104\)
- Switched Backup Operation (not for MX-2104)
- Switch Mode
- System Management
- System Timing Considerations
- DTE Timing (KML.1, KML.2, KML.3, KML.4 and KML.10 Modules)
- External DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- Internal Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- Loopback Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- DCE Timing (KML.7, KML.8, and KML.F Modules)
- Main Link Timing Considerations in Bypassing and Multidrop Configurations
- Data Channel Clock Modes
- Timing Modes of ISDN Channels
- Sub Link Timing
- Main Link Interface Characteristics
- V.35 Interface (Module KML.1)
- RS-232 Interface (Module KML.2)
- V.36/RS-422/RS-530 Interface (Module KML.3)
- X.21 Interface (Module KML.4)
- G.703 Codirectional Interface (Module KML.5)
- Standard DDS CSU/DSU (Module KML.6)
- T1 Link Interface (Module KML.7)
- E1 Link Interface (Module KML.8)
- ISDN "S" Interface (Module KML.10/S)
- ISDN "U" Interface (Module KML.10/U)
- Fiber-Optic Link Interface (Module KML.F)
- I/O Module Applications
- Technical System Characteristics
- Chapter 2 Installation
- Introduction
- Site Requirements and Prerequisites
- Input Power Requirements
- Grounding
- Channel Connection Considerations
- Front and Rear Panel Clearance
- Ambient Requirements
- Electromagnetic Compatibility Considerations
- Current and Power Requirements of MX-2100 Power Supply Modules
- Current and Power Capabilities of MX-2100 Power Supply Modules
- Ratings of Ring and Feed Voltage Supplies
- Equipment Needed
- Package Contents
- Installation and Setup of MX-2100
- Interfaces and Connections
- Initial Setup and Configuration
- Chapter 3 Configuring MX-2100
- Chapter 4 Operation
- Chapter 5 Diagnostics
- Appendix A Connection Data
- Appendix B Alarms
- Appendix C SNMP Management
- Appendix D Software Download
- Appendix E Configuration Parameters
- Appendix F Command Set Description
- General
- Commands
- BYE
- CLR ALM
- CLR LOOP
- CLR MONITOR
- CONNECT SWITCH
- DATE
- DEF AGENDA
- DEF AGENT
- DEF ALM DEBOUNCE
- DEF CALL
- DEF CH
- DEF CON
- DEF DB FLIP
- DEF DP
- DEF FRAME
- DEF MANAGER LIST
- DEF ML
- DEF ML CALL
- DEF NAME
- DEF NODE
- DEF NP
- DEF PWD
- DEF ROUTE
- DEF SP
- DEF SYS
- DISCONNECT SWITCH
- DSP AGENT
- DSP ALM
- DSP BERT
- DSP CH CON
- DSP FLIP
- DSP HDR TST
- DSP MANAGER LIST
- DSP KVF5orDSP PBX
- DSP KVF6
- DSP SIGNALINGorDSP SIG
- DSP PRBS_INJ
- DSP REM AGENT
- DSP REV
- DSP ST FRAME
- DSP ST ML
- DSP ST SLOT
- DSP ST SYS
- EDIT DB
- EXIT
- F
- FLIP ML
- HELP
- INIT DB
- INIT F
- LOAD DB 1\2
- LOAD IO
- LOOP
- ML RECOVERY
- MONITOR
- REBUILD FRAME
- RESET LOC
- RESET IO
- RESET ML
- TIME
- UPDATE DB 1\2
- Index
- DC Power Supply Connection

Appendix F Command Set Description MX-2100/2104 Installation and Operation Manual
F-28 Commands
DEF SP
Purpose
Assign values to supervisory port parameters. See section Supervisory Port
Configuration Parameters in Appendix E for parameter description and allowable
ranges, and section Configuring the SP Parameters in Chapter 3 for practical
selection recommendations.
Format
DEF SP
Use
1. Type
DEF SP <ENTER>
The supervisory port parameters data form is displayed. The data form lists
the parameters on two separate lines. A typical complete form is shown
below. The form presents the current parameter values as defaults.
SPEED DATA PARITY INTERFACE CTS DCD_DEL DSR
9.6 kbps 8 NONE DCE ON 10 ON
POP_ALM PWD LOG_OFF AUXILIARY_DEVICE
NO NO NO NMS_SLIP
2. Change parameters as follows:
Bring the cursor to the beginning of the first field to be changed by
pressing the space bar.
To change the selected field, press F or B to scroll among the available
selections. When the desired selection is displayed, press the space bar
to move to the next field.
3. After the desired parameter values are selected, press ENTER to end.
MX-2100 will display the time and date fields, followed by the MX-2100 prompt.
In addition to the parameters listed in Supervisory Port Configuration Parameters
in the Configuration Parameters appendix, Table F-4 lists parameters which can be
programmed only from the terminal:
Table F-4. Terminal Programmed Parameters
Designation Function Values
SPEED Selects the data rate. 9.6, 19.2, 38.4 or 57.6 kbps
CTS - ON The CTS line is always ON (active). =RTS - The CTS line follows the RTS line.
DCD_DELAY With the MX-2100 supervisory port
defined as DTE, indicates delay (in
msec) between DCD=ON and the
sending of data.
0, 10, 50, 100, 200, 300 msec