Specifications

Table Of Contents
Appendix F Command Set Description MX-2100/2104 Installation and Operation Manual
F-16 Commands
Use
1. Type:
DEF DP <ENTER>
If the KCL.2 module has an Ethernet interface, the following is displayed:
ROUTING_PROTOCOL
NONE
where NONE is the default value.
If the KCL.2 module has RS-232 interfaces, the following is displayed:
SPEED DATA PARITY CALL_OUT_MODE
9600 8 NONE NO
where the parameter values are the default values.
2. Change the parameter values as follows:
Bring the cursor to the beginning of the first field to be changed by
pressing the space bar.
To change the selected field, press F or B to scroll among the available
selections.
When the desired selection is displayed, press the space bar to move to
the next field.
When done, press ENTER.
The second line of parameters is displayed. The following is a typical
display:
LOG_OFF AUXILIARY_DEVICE ROUTING_PROTOCOL
NO NMS_SLIP NONE
Table F-2 shows the dial-out parameters and their values.
Table F-2. Dial-out Parameters
Designation Function Values
SPEED Selects the dial-out port data rate. 300, 1200, 2400, 4800, 9600, 19200, 38400 and
57600 bps
DATA Selects the number of data bits in the
dial-out port word format:
7 or 8 data bits
PARITY Controls the use of parity. ODD - Odd parity
ODD - Odd parity
EVEN - Even parity
NO - Parity disabled (only available with 8 data bits).
CALL_OUT_MODE Controls the use of the call-out
function:
NO - Call-out function is disabled.
YES - MX-2100 will initiate a call after each new
alarm.