Specifications
Table Of Contents
- Preface
- Quick Start Guide
- Table of Contents
- Chapter 1 General Information
- Functional Description
- Physical Description
- Application Considerations
- Basic MX-2100 System
- Redundancy (not for MX-2104)
- Dual Link Operation (not for MX-2104)
- Priority Bumping \(not for MX2104\)
- Switched Backup Operation (not for MX-2104)
- Switch Mode
- System Management
- System Timing Considerations
- DTE Timing (KML.1, KML.2, KML.3, KML.4 and KML.10 Modules)
- External DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- Internal Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- Loopback Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- DCE Timing (KML.7, KML.8, and KML.F Modules)
- Main Link Timing Considerations in Bypassing and Multidrop Configurations
- Data Channel Clock Modes
- Timing Modes of ISDN Channels
- Sub Link Timing
- Main Link Interface Characteristics
- V.35 Interface (Module KML.1)
- RS-232 Interface (Module KML.2)
- V.36/RS-422/RS-530 Interface (Module KML.3)
- X.21 Interface (Module KML.4)
- G.703 Codirectional Interface (Module KML.5)
- Standard DDS CSU/DSU (Module KML.6)
- T1 Link Interface (Module KML.7)
- E1 Link Interface (Module KML.8)
- ISDN "S" Interface (Module KML.10/S)
- ISDN "U" Interface (Module KML.10/U)
- Fiber-Optic Link Interface (Module KML.F)
- I/O Module Applications
- Technical System Characteristics
- Chapter 2 Installation
- Introduction
- Site Requirements and Prerequisites
- Input Power Requirements
- Grounding
- Channel Connection Considerations
- Front and Rear Panel Clearance
- Ambient Requirements
- Electromagnetic Compatibility Considerations
- Current and Power Requirements of MX-2100 Power Supply Modules
- Current and Power Capabilities of MX-2100 Power Supply Modules
- Ratings of Ring and Feed Voltage Supplies
- Equipment Needed
- Package Contents
- Installation and Setup of MX-2100
- Interfaces and Connections
- Initial Setup and Configuration
- Chapter 3 Configuring MX-2100
- Chapter 4 Operation
- Chapter 5 Diagnostics
- Appendix A Connection Data
- Appendix B Alarms
- Appendix C SNMP Management
- Appendix D Software Download
- Appendix E Configuration Parameters
- Appendix F Command Set Description
- General
- Commands
- BYE
- CLR ALM
- CLR LOOP
- CLR MONITOR
- CONNECT SWITCH
- DATE
- DEF AGENDA
- DEF AGENT
- DEF ALM DEBOUNCE
- DEF CALL
- DEF CH
- DEF CON
- DEF DB FLIP
- DEF DP
- DEF FRAME
- DEF MANAGER LIST
- DEF ML
- DEF ML CALL
- DEF NAME
- DEF NODE
- DEF NP
- DEF PWD
- DEF ROUTE
- DEF SP
- DEF SYS
- DISCONNECT SWITCH
- DSP AGENT
- DSP ALM
- DSP BERT
- DSP CH CON
- DSP FLIP
- DSP HDR TST
- DSP MANAGER LIST
- DSP KVF5orDSP PBX
- DSP KVF6
- DSP SIGNALINGorDSP SIG
- DSP PRBS_INJ
- DSP REM AGENT
- DSP REV
- DSP ST FRAME
- DSP ST ML
- DSP ST SLOT
- DSP ST SYS
- EDIT DB
- EXIT
- F
- FLIP ML
- HELP
- INIT DB
- INIT F
- LOAD DB 1\2
- LOAD IO
- LOOP
- ML RECOVERY
- MONITOR
- REBUILD FRAME
- RESET LOC
- RESET IO
- RESET ML
- TIME
- UPDATE DB 1\2
- Index
- DC Power Supply Connection

MX-2100/2104 Installation and Operation Manual Chapter 1 General Information
Functional Description 1-3
The MX-2104 system can be equipped with only one main link. The 3U high
MX-2100 system can be equipped with two main link modules. Two main link
modules in an MX-2100 system, can be used in several ways:
• To provide hot-standby redundancy (backup) for the main link, with automatic or
manual switchover in case one of the links fails. For maximum flexibility, MX-2100
allows the preparation of a different configuration for use on the backup link. The
backup link can also use a switched data circuit. The switched circuit can be
established on a PSTN line, using analog modems, or on an ISDN line using an S
or U interface.
• To provide two independent links from the same MX-2100 enclosure. The two
links can operate at different data rates. The dual-link mode can also be used
for providing the equivalent of hot standby protection to critical data channels
(by enabling the priority bumping feature).
• To provide multidrop and bypass capabilities (using a dedicated KDI module).
In addition to main link redundancy, the MX-2100 system reliability can be further
enhanced by installing an additional power supply unit in the enclosure. The
power supplies share the load current, therefore when one of them fails or its
input voltage is disconnected, the other takes over the full load without
disturbance to MX-2100 operation.
The MX-2100/2104 system provides flexible system timing options, with several
main link, and channel timing modes.
The main link timing modes are DTE, DCE, and external DCE. In the DCE and
external DCE modes, the timing reference source can be selected by the user:
• Internal oscillator
• External (timing locked to one of the data channels)
• The other main link module (provided a KDI module is installed).
In addition to the main timing source, a fallback source can be selected. When the
timing mode is DTE or external DCE, buffers are inserted in the main link signal
paths, to absorb the expected jitter and timing instabilities. Normal buffer size is
±8 bits; for operation over satellite links, the receive buffer size can be increased to
±256 bits.
The timing modes available for the data channels are programmable, thereby
permitting each channel to be configured as either DCE (supplies receive and
transmit clocks to the user's equipment), DTE1 (supplies the receive clock and
accept a transmit clock), or DTE2 (accepts receive and transmit clocks from the
user's equipment), with buffered retiming of the received data. Connection to the
national network and to common-carrier data lines is also supported, with the
external clock selectable as the source for system timing.
For modules with ISDN, T1, E1, and fiber-optic interfaces, a loopback timing
mode is available. This mode enables locking the MX-2100 timing to the accurate
timing provided by the network to which the interface is connected.