Specifications
Table Of Contents
- Preface
- Quick Start Guide
- Table of Contents
- Chapter 1 General Information
- Functional Description
- Physical Description
- Application Considerations
- Basic MX-2100 System
- Redundancy (not for MX-2104)
- Dual Link Operation (not for MX-2104)
- Priority Bumping \(not for MX2104\)
- Switched Backup Operation (not for MX-2104)
- Switch Mode
- System Management
- System Timing Considerations
- DTE Timing (KML.1, KML.2, KML.3, KML.4 and KML.10 Modules)
- External DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- Internal Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- Loopback Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- DCE Timing (KML.7, KML.8, and KML.F Modules)
- Main Link Timing Considerations in Bypassing and Multidrop Configurations
- Data Channel Clock Modes
- Timing Modes of ISDN Channels
- Sub Link Timing
- Main Link Interface Characteristics
- V.35 Interface (Module KML.1)
- RS-232 Interface (Module KML.2)
- V.36/RS-422/RS-530 Interface (Module KML.3)
- X.21 Interface (Module KML.4)
- G.703 Codirectional Interface (Module KML.5)
- Standard DDS CSU/DSU (Module KML.6)
- T1 Link Interface (Module KML.7)
- E1 Link Interface (Module KML.8)
- ISDN "S" Interface (Module KML.10/S)
- ISDN "U" Interface (Module KML.10/U)
- Fiber-Optic Link Interface (Module KML.F)
- I/O Module Applications
- Technical System Characteristics
- Chapter 2 Installation
- Introduction
- Site Requirements and Prerequisites
- Input Power Requirements
- Grounding
- Channel Connection Considerations
- Front and Rear Panel Clearance
- Ambient Requirements
- Electromagnetic Compatibility Considerations
- Current and Power Requirements of MX-2100 Power Supply Modules
- Current and Power Capabilities of MX-2100 Power Supply Modules
- Ratings of Ring and Feed Voltage Supplies
- Equipment Needed
- Package Contents
- Installation and Setup of MX-2100
- Interfaces and Connections
- Initial Setup and Configuration
- Chapter 3 Configuring MX-2100
- Chapter 4 Operation
- Chapter 5 Diagnostics
- Appendix A Connection Data
- Appendix B Alarms
- Appendix C SNMP Management
- Appendix D Software Download
- Appendix E Configuration Parameters
- Appendix F Command Set Description
- General
- Commands
- BYE
- CLR ALM
- CLR LOOP
- CLR MONITOR
- CONNECT SWITCH
- DATE
- DEF AGENDA
- DEF AGENT
- DEF ALM DEBOUNCE
- DEF CALL
- DEF CH
- DEF CON
- DEF DB FLIP
- DEF DP
- DEF FRAME
- DEF MANAGER LIST
- DEF ML
- DEF ML CALL
- DEF NAME
- DEF NODE
- DEF NP
- DEF PWD
- DEF ROUTE
- DEF SP
- DEF SYS
- DISCONNECT SWITCH
- DSP AGENT
- DSP ALM
- DSP BERT
- DSP CH CON
- DSP FLIP
- DSP HDR TST
- DSP MANAGER LIST
- DSP KVF5orDSP PBX
- DSP KVF6
- DSP SIGNALINGorDSP SIG
- DSP PRBS_INJ
- DSP REM AGENT
- DSP REV
- DSP ST FRAME
- DSP ST ML
- DSP ST SLOT
- DSP ST SYS
- EDIT DB
- EXIT
- F
- FLIP ML
- HELP
- INIT DB
- INIT F
- LOAD DB 1\2
- LOAD IO
- LOOP
- ML RECOVERY
- MONITOR
- REBUILD FRAME
- RESET LOC
- RESET IO
- RESET ML
- TIME
- UPDATE DB 1\2
- Index
- DC Power Supply Connection

Appendix F Command Set Description MX-2100/2104 Installation and Operation Manual
F-4 Commands
If the desired module is a module for which it is not possible to loops or tests on a
specific channel, e.g., a KLS.2 module, type an asterisk * instead of the channel
number, B.
5. To deactivate all the channel loop and tests, type:
CLR LOOP i:j <ENTER> or CLR LP i:j <ENTER>
Use the asterisk under the conditions explained above.
You will see the time and date, followed by the MX-2100 prompt.
CLR MONITOR
Purpose
Deactivate the monitoring of an I/O module channel.
Format
CLR MONITOR or CLR M
Use
• To deactivate the monitoring of the currently selected I/O channel, type:
CLR MONITOR <ENTER> or CLR M <ENTER>
You will see the time and date, followed by the MX-2100 prompt.
CONNECT SWITCH
Purpose
Dials and connects to the remote MX-2100 from the local MX-2100’s main link
over the ISDN switch line when the following is true:
• The MX-2100’s main link is configured to manual operation and switch mode
(refer to DEF ML command).
• The system is in switch mode (refer to DEF SYS command).
The link will be connected until the DISCONNECT SWITCH command is activated
or until reset. Refer to DISCONNECT SWITCH on page F-32.
Format
CONNECT SWITCH [A] [B]
Use
• Type:
CONNECT SWITCH A <ENTER>
or
CONNECT SWITCH B <ENTER>
Note