Specifications
Table Of Contents
- Preface
- Quick Start Guide
- Table of Contents
- Chapter 1 General Information
- Functional Description
- Physical Description
- Application Considerations
- Basic MX-2100 System
- Redundancy (not for MX-2104)
- Dual Link Operation (not for MX-2104)
- Priority Bumping \(not for MX2104\)
- Switched Backup Operation (not for MX-2104)
- Switch Mode
- System Management
- System Timing Considerations
- DTE Timing (KML.1, KML.2, KML.3, KML.4 and KML.10 Modules)
- External DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- Internal Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- Loopback Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- DCE Timing (KML.7, KML.8, and KML.F Modules)
- Main Link Timing Considerations in Bypassing and Multidrop Configurations
- Data Channel Clock Modes
- Timing Modes of ISDN Channels
- Sub Link Timing
- Main Link Interface Characteristics
- V.35 Interface (Module KML.1)
- RS-232 Interface (Module KML.2)
- V.36/RS-422/RS-530 Interface (Module KML.3)
- X.21 Interface (Module KML.4)
- G.703 Codirectional Interface (Module KML.5)
- Standard DDS CSU/DSU (Module KML.6)
- T1 Link Interface (Module KML.7)
- E1 Link Interface (Module KML.8)
- ISDN "S" Interface (Module KML.10/S)
- ISDN "U" Interface (Module KML.10/U)
- Fiber-Optic Link Interface (Module KML.F)
- I/O Module Applications
- Technical System Characteristics
- Chapter 2 Installation
- Introduction
- Site Requirements and Prerequisites
- Input Power Requirements
- Grounding
- Channel Connection Considerations
- Front and Rear Panel Clearance
- Ambient Requirements
- Electromagnetic Compatibility Considerations
- Current and Power Requirements of MX-2100 Power Supply Modules
- Current and Power Capabilities of MX-2100 Power Supply Modules
- Ratings of Ring and Feed Voltage Supplies
- Equipment Needed
- Package Contents
- Installation and Setup of MX-2100
- Interfaces and Connections
- Initial Setup and Configuration
- Chapter 3 Configuring MX-2100
- Chapter 4 Operation
- Chapter 5 Diagnostics
- Appendix A Connection Data
- Appendix B Alarms
- Appendix C SNMP Management
- Appendix D Software Download
- Appendix E Configuration Parameters
- Appendix F Command Set Description
- General
- Commands
- BYE
- CLR ALM
- CLR LOOP
- CLR MONITOR
- CONNECT SWITCH
- DATE
- DEF AGENDA
- DEF AGENT
- DEF ALM DEBOUNCE
- DEF CALL
- DEF CH
- DEF CON
- DEF DB FLIP
- DEF DP
- DEF FRAME
- DEF MANAGER LIST
- DEF ML
- DEF ML CALL
- DEF NAME
- DEF NODE
- DEF NP
- DEF PWD
- DEF ROUTE
- DEF SP
- DEF SYS
- DISCONNECT SWITCH
- DSP AGENT
- DSP ALM
- DSP BERT
- DSP CH CON
- DSP FLIP
- DSP HDR TST
- DSP MANAGER LIST
- DSP KVF5orDSP PBX
- DSP KVF6
- DSP SIGNALINGorDSP SIG
- DSP PRBS_INJ
- DSP REM AGENT
- DSP REV
- DSP ST FRAME
- DSP ST ML
- DSP ST SLOT
- DSP ST SYS
- EDIT DB
- EXIT
- F
- FLIP ML
- HELP
- INIT DB
- INIT F
- LOAD DB 1\2
- LOAD IO
- LOOP
- ML RECOVERY
- MONITOR
- REBUILD FRAME
- RESET LOC
- RESET IO
- RESET ML
- TIME
- UPDATE DB 1\2
- Index
- DC Power Supply Connection

MX-2100/2104 Installation and Operation Manual Appendix B Alarms
Configuration Error Messages B-13
ERROR 26 MODULE TYPE MISMATCH BETWEEN DATABASE AND HARDWARE
The module type recorded in the MX-2100 data base differs from the module
sensed by the MX-2100.
ERROR 27 ILLEGAL CLOCK SELECTION FOR MODULE TYPE
The selected timing mode is not supported by the module whose number has
been specified in the command.
ERROR 28 ILLEGAL COMMAND FOR INSTALLED MODULE
The command you have entered is not supported by the module whose number
has been specified in the command.
ERROR 30 ILLEGAL DCD_DEL AND INTERFACE COMBINATION
The DCD_DEL parameter is not supported by the selected supervisory port
interface (the DCD DEL parameter must be 0 when the supervisory port interface
is DCE).
ERROR 31 ILLEGAL COMMAND, DOWNLOAD NOT SUPPORTED
The command you have entered cannot be executed when downloading is
disabled.
ERROR 32 ILLEGAL PROTOCOL AND TIMING COMBINATION
You are trying to select a channel timing mode for a data channel configured for
asynchronous operation.
ERROR 33 REDUNDANT ML NOT INSTALLED
No redundant KML module is installed.
ERROR 34 DISCONNECT LOOP BEFORE CONFIGURATION CHANGE
You are trying to change the configuration while a loop is activate this is not
allowed.
ERROR 35 ILLEGAL TIME DIVISION DEFINITION (<day>)
The periods defined by means of the DEF AGENDA commands are not correctly
sequenced.
ERROR 36 ILLEGAL DATA BASE FLIP TIME
You must define two valid data base flip times.
ERROR 37 CONFLICT IN INTERFACE AND DSR PARAMETER
You are trying to select DSR=ON after the supervisory port interface has been set to
DTE.
ERROR 38 ILLEGAL COMMAND, ALTERNATE DATA BASE IS ACTIVE
The command entered by you is not supported on the alternate data base (only
DEF commands are supported).