Specifications
Table Of Contents
- Preface
- Quick Start Guide
- Table of Contents
- Chapter 1 General Information
- Functional Description
- Physical Description
- Application Considerations
- Basic MX-2100 System
- Redundancy (not for MX-2104)
- Dual Link Operation (not for MX-2104)
- Priority Bumping \(not for MX2104\)
- Switched Backup Operation (not for MX-2104)
- Switch Mode
- System Management
- System Timing Considerations
- DTE Timing (KML.1, KML.2, KML.3, KML.4 and KML.10 Modules)
- External DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- Internal Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- Loopback Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- DCE Timing (KML.7, KML.8, and KML.F Modules)
- Main Link Timing Considerations in Bypassing and Multidrop Configurations
- Data Channel Clock Modes
- Timing Modes of ISDN Channels
- Sub Link Timing
- Main Link Interface Characteristics
- V.35 Interface (Module KML.1)
- RS-232 Interface (Module KML.2)
- V.36/RS-422/RS-530 Interface (Module KML.3)
- X.21 Interface (Module KML.4)
- G.703 Codirectional Interface (Module KML.5)
- Standard DDS CSU/DSU (Module KML.6)
- T1 Link Interface (Module KML.7)
- E1 Link Interface (Module KML.8)
- ISDN "S" Interface (Module KML.10/S)
- ISDN "U" Interface (Module KML.10/U)
- Fiber-Optic Link Interface (Module KML.F)
- I/O Module Applications
- Technical System Characteristics
- Chapter 2 Installation
- Introduction
- Site Requirements and Prerequisites
- Input Power Requirements
- Grounding
- Channel Connection Considerations
- Front and Rear Panel Clearance
- Ambient Requirements
- Electromagnetic Compatibility Considerations
- Current and Power Requirements of MX-2100 Power Supply Modules
- Current and Power Capabilities of MX-2100 Power Supply Modules
- Ratings of Ring and Feed Voltage Supplies
- Equipment Needed
- Package Contents
- Installation and Setup of MX-2100
- Interfaces and Connections
- Initial Setup and Configuration
- Chapter 3 Configuring MX-2100
- Chapter 4 Operation
- Chapter 5 Diagnostics
- Appendix A Connection Data
- Appendix B Alarms
- Appendix C SNMP Management
- Appendix D Software Download
- Appendix E Configuration Parameters
- Appendix F Command Set Description
- General
- Commands
- BYE
- CLR ALM
- CLR LOOP
- CLR MONITOR
- CONNECT SWITCH
- DATE
- DEF AGENDA
- DEF AGENT
- DEF ALM DEBOUNCE
- DEF CALL
- DEF CH
- DEF CON
- DEF DB FLIP
- DEF DP
- DEF FRAME
- DEF MANAGER LIST
- DEF ML
- DEF ML CALL
- DEF NAME
- DEF NODE
- DEF NP
- DEF PWD
- DEF ROUTE
- DEF SP
- DEF SYS
- DISCONNECT SWITCH
- DSP AGENT
- DSP ALM
- DSP BERT
- DSP CH CON
- DSP FLIP
- DSP HDR TST
- DSP MANAGER LIST
- DSP KVF5orDSP PBX
- DSP KVF6
- DSP SIGNALINGorDSP SIG
- DSP PRBS_INJ
- DSP REM AGENT
- DSP REV
- DSP ST FRAME
- DSP ST ML
- DSP ST SLOT
- DSP ST SYS
- EDIT DB
- EXIT
- F
- FLIP ML
- HELP
- INIT DB
- INIT F
- LOAD DB 1\2
- LOAD IO
- LOOP
- ML RECOVERY
- MONITOR
- REBUILD FRAME
- RESET LOC
- RESET IO
- RESET ML
- TIME
- UPDATE DB 1\2
- Index
- DC Power Supply Connection

Appendix B Alarms MX-2100/2104 Installation and Operation Manual
B-10 Configuration Error Messages
B.2 Configuration Error Messages
The MX-2100 provides configuration error messages for the LCD and for the
supervision terminal.
• The configuration error messages displayed on the LCD have the format
CONFIG ERROR, followed by a numerical code.
• The configuration messages have the format ERROR, followed by the
numerical code, and a concise textual description of the error condition.
The error messages are explained below:
ERROR 01 ILLEGAL MASTER CLOCK SOURCE (CARD TIMING/SPEED)
Illegal source for a master clock timing reference source: the selected channel is
not operating in the DTE2 mode.
ERROR 02 ILLEGAL FALLBACK CLOCK SOURCE (CARD TIMING/SPEED)
Illegal source for a fallback clock timing reference source: the selected channel is
not operating in the DTE2 mode.
ERROR 03 ILLEGAL ML LOOP COMBINATION
You are trying to activate simultaneously local and main link loops, or both types
of ITU-T Rec. V.54 main link loops (LOOP 2 and LOOP 3). This combination is
not allowed (refer to the Diagnostics chapter).
ERROR 04 ILLEGAL I/O MODULE LOOP COMBINATION
You are trying to activate simultaneously both a local and remote loop or PRBS
transmission, or BERT test, or tone injection, on the same channel. None of these
combinations are allowed (refer to the Diagnostics chapter).
ERROR 05 ILLEGAL COMBINATION OF CHANNEL SPEED AND PROTOCOL
Conflict in the channel parameters of the KLS.1 module being configured: you are
trying to select a data rate of 38.4 kbps, but the channel is configured for
asynchronous operation. The maximum data rate for asynchronous operation is
19.2 kbps.
ERROR 06 ILLEGAL NUMBER OF MODULE CONTROL SIGNALS
The number of control signals that can be transmitted for any module is none, 1, 2
or 4. You are trying to select a forbidden value, e.g., you cannot select RTS on one
channel of a given module, and DTR and RTS on another channel of the same
module.