Specifications
Table Of Contents
- Preface
- Quick Start Guide
- Table of Contents
- Chapter 1 General Information
- Functional Description
- Physical Description
- Application Considerations
- Basic MX-2100 System
- Redundancy (not for MX-2104)
- Dual Link Operation (not for MX-2104)
- Priority Bumping \(not for MX2104\)
- Switched Backup Operation (not for MX-2104)
- Switch Mode
- System Management
- System Timing Considerations
- DTE Timing (KML.1, KML.2, KML.3, KML.4 and KML.10 Modules)
- External DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- Internal Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- Loopback Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- DCE Timing (KML.7, KML.8, and KML.F Modules)
- Main Link Timing Considerations in Bypassing and Multidrop Configurations
- Data Channel Clock Modes
- Timing Modes of ISDN Channels
- Sub Link Timing
- Main Link Interface Characteristics
- V.35 Interface (Module KML.1)
- RS-232 Interface (Module KML.2)
- V.36/RS-422/RS-530 Interface (Module KML.3)
- X.21 Interface (Module KML.4)
- G.703 Codirectional Interface (Module KML.5)
- Standard DDS CSU/DSU (Module KML.6)
- T1 Link Interface (Module KML.7)
- E1 Link Interface (Module KML.8)
- ISDN "S" Interface (Module KML.10/S)
- ISDN "U" Interface (Module KML.10/U)
- Fiber-Optic Link Interface (Module KML.F)
- I/O Module Applications
- Technical System Characteristics
- Chapter 2 Installation
- Introduction
- Site Requirements and Prerequisites
- Input Power Requirements
- Grounding
- Channel Connection Considerations
- Front and Rear Panel Clearance
- Ambient Requirements
- Electromagnetic Compatibility Considerations
- Current and Power Requirements of MX-2100 Power Supply Modules
- Current and Power Capabilities of MX-2100 Power Supply Modules
- Ratings of Ring and Feed Voltage Supplies
- Equipment Needed
- Package Contents
- Installation and Setup of MX-2100
- Interfaces and Connections
- Initial Setup and Configuration
- Chapter 3 Configuring MX-2100
- Chapter 4 Operation
- Chapter 5 Diagnostics
- Appendix A Connection Data
- Appendix B Alarms
- Appendix C SNMP Management
- Appendix D Software Download
- Appendix E Configuration Parameters
- Appendix F Command Set Description
- General
- Commands
- BYE
- CLR ALM
- CLR LOOP
- CLR MONITOR
- CONNECT SWITCH
- DATE
- DEF AGENDA
- DEF AGENT
- DEF ALM DEBOUNCE
- DEF CALL
- DEF CH
- DEF CON
- DEF DB FLIP
- DEF DP
- DEF FRAME
- DEF MANAGER LIST
- DEF ML
- DEF ML CALL
- DEF NAME
- DEF NODE
- DEF NP
- DEF PWD
- DEF ROUTE
- DEF SP
- DEF SYS
- DISCONNECT SWITCH
- DSP AGENT
- DSP ALM
- DSP BERT
- DSP CH CON
- DSP FLIP
- DSP HDR TST
- DSP MANAGER LIST
- DSP KVF5orDSP PBX
- DSP KVF6
- DSP SIGNALINGorDSP SIG
- DSP PRBS_INJ
- DSP REM AGENT
- DSP REV
- DSP ST FRAME
- DSP ST ML
- DSP ST SLOT
- DSP ST SYS
- EDIT DB
- EXIT
- F
- FLIP ML
- HELP
- INIT DB
- INIT F
- LOAD DB 1\2
- LOAD IO
- LOOP
- ML RECOVERY
- MONITOR
- REBUILD FRAME
- RESET LOC
- RESET IO
- RESET ML
- TIME
- UPDATE DB 1\2
- Index
- DC Power Supply Connection

MX-2100/2104 Installation and Operation Manual Appendix B Alarms
Alarm Messages B-7
Table B-1. LCD Alarm Messages (Cont.)
Code Message - LCD Message - Terminal Alarm
Type
Description
59 EXE ERR RAT EXECIVE ERR RATIO,
SLOT i
State The error rate detected on the frame
synchronization bits is high (as defined
by ITU-T Rec. G.732), and may indicate
hardware problems or defective
connections
60 CRC-4 ERROR CRC-4 ERROR, SLOT i Event The main link module reports the
detection of a CRC error
61 B.R.G FAIL SFIFO B.R.G FAIL,
SLOT i
State The baud rate generator of the specified
module failed. Replace the module
62 SFIFO SLIP SFIFO SLIP, SLOT i Event The KML.7 module installed in the
specified slot reports that a slip occurred
in the SFIFO
63 INT CLK USE INTERNAL CLOCK IN
USE, SLOT i
State The internal oscillator has been selected
as a timing reference sources, as a result
of simultaneous failure of both the
master and fallback clock sources
64 DP – DIAL FAIL DP CYCLE DIAL FAILED Event The dial-out cycle failed, and the redial
attempts stopped until a new alarm
reported
65 DP PRI CALL FAIL DP PRIMARY CALL
FAILED
Event The call setup attempts to the primary
dial-out directory number failed
66 DP ALT.CALL FAIL DP ALTERNATE CALL
FAILED
Event The call setup attempts to the alternate
dial-out directory number failed
67 FRAMER CARD FAIL FRAMER CARD FAILED State The master KVF.5 module failed
68 MGMT P IS LOP ML-i MGMT PORT IS
LOOPED ML-i
State Management port is looped and cannot
communicate with the remote MX-2100
due to loopback activation on main link
A or B
69 MGMT DOWN ML-i MGMT PORT IS DOWN
ML-i
State MX-2100 cannot communicate to the
remote MX-2100 via in-band
management channel in main link A
or B
70 AGETS SAM NET AGENTS WITH SAME
NAME IN NET
Event There is an agent with the same name in
the network
71 TAK SNMP MMI CONTOLR TAKEN BY
SNMP MMI
Event MX-2100 is controlled by SNMP
management station
72 TAK TERM MMI CONTOLR TAKEN BY
TERM MMI
Event MX-2100 is controlled by ASCII terminal
73 TAK LCD MMI CONTOLR TAKEN BY
LCD MMI
Event MX-2100 is controlled by LCD