Specifications

Table Of Contents
MX-2100/2104 Installation and Operation Manual Chapter 5 Diagnostics
Diagnostic Tests 5-3
Simultaneous activation of local loop and PRBS transmission on the same
data channel (CONFIG ERROR 4)
Simultaneous activation of local loop and BERT test on the same channel
(CONFIG ERROR 4)
Simultaneous activation of local loop and tone injection on the same voice
channel (CONFIG ERROR 4).
Test Options Operating Instructions
The following provide detailed instructions for:
Deactivating all the tests initiated by the local MX-2100
Activating/deactivating the monitoring of a selected channel
Activating/deactivating a main link loop
Activating/deactivating a channel loop
Activating/deactivating PRBS transmission on a data channel
Activating/deactivating BERT testing on a data channel
Activating/deactivating tone injection on a voice channel
Displaying the state of channel ITU-T Rec. V.54 loops (for KLS.1 – also
activation/deactivation)
Displaying the state of loops initiated at the remote MX-2100 unit.
Table 5-1. Deactivating all the Tests
Step Action Key Display
1 Bring the cursor under the
top row (if not already
there).
CURSOR
2 Scroll to display TEST
OPTIONS in the top row.
SCROLL Second row displays the active test (or the
first active test, when several tests are
simultaneously active)
3 Bring the cursor under the
right-hand field in the top
row, and scroll to display
OFF in this field.
CURSOR
4 Press ENTER. ENTER The tests are deactivated and the TEST
indicator on the front panel of the