Specifications
Table Of Contents
- Preface
- Quick Start Guide
- Table of Contents
- Chapter 1 General Information
- Functional Description
- Physical Description
- Application Considerations
- Basic MX-2100 System
- Redundancy (not for MX-2104)
- Dual Link Operation (not for MX-2104)
- Priority Bumping \(not for MX2104\)
- Switched Backup Operation (not for MX-2104)
- Switch Mode
- System Management
- System Timing Considerations
- DTE Timing (KML.1, KML.2, KML.3, KML.4 and KML.10 Modules)
- External DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- Internal Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- Loopback Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- DCE Timing (KML.7, KML.8, and KML.F Modules)
- Main Link Timing Considerations in Bypassing and Multidrop Configurations
- Data Channel Clock Modes
- Timing Modes of ISDN Channels
- Sub Link Timing
- Main Link Interface Characteristics
- V.35 Interface (Module KML.1)
- RS-232 Interface (Module KML.2)
- V.36/RS-422/RS-530 Interface (Module KML.3)
- X.21 Interface (Module KML.4)
- G.703 Codirectional Interface (Module KML.5)
- Standard DDS CSU/DSU (Module KML.6)
- T1 Link Interface (Module KML.7)
- E1 Link Interface (Module KML.8)
- ISDN "S" Interface (Module KML.10/S)
- ISDN "U" Interface (Module KML.10/U)
- Fiber-Optic Link Interface (Module KML.F)
- I/O Module Applications
- Technical System Characteristics
- Chapter 2 Installation
- Introduction
- Site Requirements and Prerequisites
- Input Power Requirements
- Grounding
- Channel Connection Considerations
- Front and Rear Panel Clearance
- Ambient Requirements
- Electromagnetic Compatibility Considerations
- Current and Power Requirements of MX-2100 Power Supply Modules
- Current and Power Capabilities of MX-2100 Power Supply Modules
- Ratings of Ring and Feed Voltage Supplies
- Equipment Needed
- Package Contents
- Installation and Setup of MX-2100
- Interfaces and Connections
- Initial Setup and Configuration
- Chapter 3 Configuring MX-2100
- Chapter 4 Operation
- Chapter 5 Diagnostics
- Appendix A Connection Data
- Appendix B Alarms
- Appendix C SNMP Management
- Appendix D Software Download
- Appendix E Configuration Parameters
- Appendix F Command Set Description
- General
- Commands
- BYE
- CLR ALM
- CLR LOOP
- CLR MONITOR
- CONNECT SWITCH
- DATE
- DEF AGENDA
- DEF AGENT
- DEF ALM DEBOUNCE
- DEF CALL
- DEF CH
- DEF CON
- DEF DB FLIP
- DEF DP
- DEF FRAME
- DEF MANAGER LIST
- DEF ML
- DEF ML CALL
- DEF NAME
- DEF NODE
- DEF NP
- DEF PWD
- DEF ROUTE
- DEF SP
- DEF SYS
- DISCONNECT SWITCH
- DSP AGENT
- DSP ALM
- DSP BERT
- DSP CH CON
- DSP FLIP
- DSP HDR TST
- DSP MANAGER LIST
- DSP KVF5orDSP PBX
- DSP KVF6
- DSP SIGNALINGorDSP SIG
- DSP PRBS_INJ
- DSP REM AGENT
- DSP REV
- DSP ST FRAME
- DSP ST ML
- DSP ST SLOT
- DSP ST SYS
- EDIT DB
- EXIT
- F
- FLIP ML
- HELP
- INIT DB
- INIT F
- LOAD DB 1\2
- LOAD IO
- LOOP
- ML RECOVERY
- MONITOR
- REBUILD FRAME
- RESET LOC
- RESET IO
- RESET ML
- TIME
- UPDATE DB 1\2
- Index
- DC Power Supply Connection

Chapter 5 Diagnostics MX-2100/2104 Installation and Operation Manual
5-2 Diagnostic Tests
• ML - Control and indication of main link loops:
− Local main link loop
− Remote main link loop
− Local ITU-T Rec. V.54 loop
(ITU-T Rec. V.54 loop 2)
− Remote ITU-T Rec. V.54 loop
(ITU-T Rec. V.54 loop 3).
• i:j - Control and indication of channel loops and tests (i indicates the module
slot number, and j indicates the module channel number):
− Local channel loop
− Remote channel loop
− Tone injection (for voice channels only)
− PRBS (pseudo-random sequence) transmission, for data channels only
− BERT (bit error rate test), for data channels only. Can be performed only if
downloading is enabled.
In addition, you can see the test state at the remote MX-2100. This function is
available only when downloading is enabled.
Special Considerations
When using the MX-2100 diagnostic functions, pay attention to the following
points:
• When you select a channel for monitoring, the monitoring of any previously
selected channel is automatically interrupted.
• Generally, at any time, only one loop of a given type can be activated on the
main link, and on each of the user channels. However, the signal paths formed
when certain loops or tests are active inherently disconnect the signal paths
required by other loops.
As a typical example, consider the case of a main link remote loop: if such a
loop is activated on the local MX-2100 in response to a command sent
through the management channel by the remote MX-2100, then the operator
of the local MX-2100 can no longer activate a local main link ITU-T Rec. V.54
loop.
• On the local MX-2100, the following combinations of loops are not possible:
− Simultaneous activation of local and remote main link loops
(CONFIG ERROR 3)
− Simultaneous activation of main link ITU-T Rec. V.54 loop 2 and loop 3
(CONFIG ERROR 3)
− Simultaneous activation of local and remote loops on the same channel
(CONFIG ERROR 4)