Specifications

Table Of Contents
Chapter 4 Operation MX-2100/2104 Installation and Operation Manual
4-18 Operating Instructions
Check the settings of switch SW3 on the KCL module:
Section 1 - Master/Slave: OFF
Section 2 – DB INIT: OFF
Section 3 – PSWRD: OFF
Section 4 – DEBUG: OFF
Check that all the communication equipment serving the main links operates
properly.
Check all the configuration parameters against the prescribed set of
parameters.
Press the RESET push-button of the KCL module.
If these actions do not correct the problem, refer to Chapter 5, Diagnostics to
identify the fault and replace the corresponding module.
Turn Off
To stop equipment operation, use the following procedure:
1. If the MX-2100 includes a KM-Ringer module, first turn the KM-Ringer off
before the MX-2100.
2. Turn the MX-2100 off by setting the ON/OFF switches of the KPS modules
installed in the enclosure to OFF.