MX-2100/2104 Installation and Operation Manual Chapter 4 Operation
Operating Instructions 4-13
While the KCL module performs the power-up self-test, the supervision terminal
displays:
CL Board Self Test In Progress ....
After the self-test is completed, the result, OK or FAILED, is added to the
displayed line. MX-2100 starts reading the installed modules, and the supervision
terminal displays:
Reading Installed Modules .....
After the reading is completed, the state of the installed modules is displayed in
the following format:
SLOT 1 PS-A OK
SLOT 2 PS-B OK
SLOT 3 ML-A OK
SLOT 4 ML-B OK
SLOT 5 CL OK
I/O SLOT 1 I/O 1 OK
I/O SLOT 2 I/O 2 OK
I/O SLOT 3 I/O 3 OK
I/O SLOT 4 I/O 4 OK
I/O SLOT 5 I/O 5 OK
I/O SLOT 6 I/O 6 OK
I/O SLOT 7 I/O 7 OK
I/O SLOT 8 I/O 8 OK
I/O SLOT 9 I/O 9 OK
I/O SLOT 10 I/O 10 OK
I/O SLOT 11 I/O 11 OK
I/O SLOT 12 I/O 12 OK
If you see FAILED for any module, replace that module.
Starting a Session - Single MX-2100
When the terminal is used to control a single MX-2100, always assign node
address 0 to MX-2100. Use the following start-up sequence to connect to a
MX-2100 assigned node number 0.
1. If you use the AUTO (Autobaud) mode, press the ENTER key three times.
This allows MX-2100 to identify the terminal data rate.
Assuming that MX-2100 successfully identified the data rate of the
supervision terminal, you will be notified if MX-2100 failed the power-up
self-test:
If you see Kilomux-2100 SELFTEST FAILED, MX-2100 must first
be repaired before you can continue using it.
If MX-2100 successfully passed the power-up self-test, it displays the
following:
<BEL>Kilomux-2100 SUPERVISORY PORT ON LINE. TYPE 'H' FOR HELP
where <BEL> stands for the graphic symbol of the <BEL> code (ASCII 07).