Specifications
Table Of Contents
- Preface
- Quick Start Guide
- Table of Contents
- Chapter 1 General Information
- Functional Description
- Physical Description
- Application Considerations
- Basic MX-2100 System
- Redundancy (not for MX-2104)
- Dual Link Operation (not for MX-2104)
- Priority Bumping \(not for MX2104\)
- Switched Backup Operation (not for MX-2104)
- Switch Mode
- System Management
- System Timing Considerations
- DTE Timing (KML.1, KML.2, KML.3, KML.4 and KML.10 Modules)
- External DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- Internal Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- Loopback Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- DCE Timing (KML.7, KML.8, and KML.F Modules)
- Main Link Timing Considerations in Bypassing and Multidrop Configurations
- Data Channel Clock Modes
- Timing Modes of ISDN Channels
- Sub Link Timing
- Main Link Interface Characteristics
- V.35 Interface (Module KML.1)
- RS-232 Interface (Module KML.2)
- V.36/RS-422/RS-530 Interface (Module KML.3)
- X.21 Interface (Module KML.4)
- G.703 Codirectional Interface (Module KML.5)
- Standard DDS CSU/DSU (Module KML.6)
- T1 Link Interface (Module KML.7)
- E1 Link Interface (Module KML.8)
- ISDN "S" Interface (Module KML.10/S)
- ISDN "U" Interface (Module KML.10/U)
- Fiber-Optic Link Interface (Module KML.F)
- I/O Module Applications
- Technical System Characteristics
- Chapter 2 Installation
- Introduction
- Site Requirements and Prerequisites
- Input Power Requirements
- Grounding
- Channel Connection Considerations
- Front and Rear Panel Clearance
- Ambient Requirements
- Electromagnetic Compatibility Considerations
- Current and Power Requirements of MX-2100 Power Supply Modules
- Current and Power Capabilities of MX-2100 Power Supply Modules
- Ratings of Ring and Feed Voltage Supplies
- Equipment Needed
- Package Contents
- Installation and Setup of MX-2100
- Interfaces and Connections
- Initial Setup and Configuration
- Chapter 3 Configuring MX-2100
- Chapter 4 Operation
- Chapter 5 Diagnostics
- Appendix A Connection Data
- Appendix B Alarms
- Appendix C SNMP Management
- Appendix D Software Download
- Appendix E Configuration Parameters
- Appendix F Command Set Description
- General
- Commands
- BYE
- CLR ALM
- CLR LOOP
- CLR MONITOR
- CONNECT SWITCH
- DATE
- DEF AGENDA
- DEF AGENT
- DEF ALM DEBOUNCE
- DEF CALL
- DEF CH
- DEF CON
- DEF DB FLIP
- DEF DP
- DEF FRAME
- DEF MANAGER LIST
- DEF ML
- DEF ML CALL
- DEF NAME
- DEF NODE
- DEF NP
- DEF PWD
- DEF ROUTE
- DEF SP
- DEF SYS
- DISCONNECT SWITCH
- DSP AGENT
- DSP ALM
- DSP BERT
- DSP CH CON
- DSP FLIP
- DSP HDR TST
- DSP MANAGER LIST
- DSP KVF5orDSP PBX
- DSP KVF6
- DSP SIGNALINGorDSP SIG
- DSP PRBS_INJ
- DSP REM AGENT
- DSP REV
- DSP ST FRAME
- DSP ST ML
- DSP ST SLOT
- DSP ST SYS
- EDIT DB
- EXIT
- F
- FLIP ML
- HELP
- INIT DB
- INIT F
- LOAD DB 1\2
- LOAD IO
- LOOP
- ML RECOVERY
- MONITOR
- REBUILD FRAME
- RESET LOC
- RESET IO
- RESET ML
- TIME
- UPDATE DB 1\2
- Index
- DC Power Supply Connection

MX-2100/2104 Installation and Operation Manual Chapter 4 Operation
MX-2100 Supervision Language 4-5
Table 4-2. MX-2100 Command Set Index (Cont.)
Command Purpose Options
CLR MONITOR
CLR M
Deactivate I/O module channel monitor
CONNECT
SWITCH
Connect ISDN line between a local and remote MX-2100 A B
DATE Set the date for the MX-2100 internal clock
DEF AGENDA Define a daily schedule for operation in the switched backup mode
DEF AGENT Define the IP parameters to the local MX-2100
DEF ALM
DEBOUNCE
Define the debounce time in seconds for each alarm code or mask the
alarm
DEF CALL Define the dial-out parameters for the dial-out port
DEF CH Configure the parameters of a selected module channel (voice or data)
DEF CON Define the main link and priorities of each module
DEF DB FLIP Define the times of day for the switching (flipping) between the two
databases
DEF DP Define the parameters of the dial-out port
DEF FRAME Define manually the allocation of main link bits
DEF MANAGER
LIST
Define or modify the network management stations to which the SNMP
agent sends traps
DEF ML Define parameters for the main link
DEF ML CALL Define the switched backup connection setup parameters (for use in
the switched backup mode)
DEF NAME Define the logical name of MX-2100
DEF NODE Define the node number of MX-2100
DEF NP Define the configuration parameters of the network port
DEF PWD Define new password, and/or display the current password
DEF ROUTE Enables static routing via the ETHERNET management port
DEF SP Configure supervisory port parameters
DEF SYS Configure system parameters
DISCONNECT
SWITCH
Disconnect the ISDN line between the local and remote MX-2100 A B
DSP AGENT Display the IP and SNMP agent parameters
DSP ALM Display the contents of the alarm buffer and optionally clear the buffer /C
/CA
DSP BERT Display the result of the BERT test running on an I/O module channel /C
DSP CH CON Display information on connected channels
DSP HDR TST Display hardware faults (detected during the power-on self-test, and
during normal operation)