Specifications
Table Of Contents
- Preface
- Quick Start Guide
- Table of Contents
- Chapter 1 General Information
- Functional Description
- Physical Description
- Application Considerations
- Basic MX-2100 System
- Redundancy (not for MX-2104)
- Dual Link Operation (not for MX-2104)
- Priority Bumping \(not for MX2104\)
- Switched Backup Operation (not for MX-2104)
- Switch Mode
- System Management
- System Timing Considerations
- DTE Timing (KML.1, KML.2, KML.3, KML.4 and KML.10 Modules)
- External DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- DCE Timing (KML.1, KML.2, KML.3 and KML.4 Modules)
- Internal Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- Loopback Timing (KML.5, KML.6, KML.7, KML.8, and KML.F Modules)
- DCE Timing (KML.7, KML.8, and KML.F Modules)
- Main Link Timing Considerations in Bypassing and Multidrop Configurations
- Data Channel Clock Modes
- Timing Modes of ISDN Channels
- Sub Link Timing
- Main Link Interface Characteristics
- V.35 Interface (Module KML.1)
- RS-232 Interface (Module KML.2)
- V.36/RS-422/RS-530 Interface (Module KML.3)
- X.21 Interface (Module KML.4)
- G.703 Codirectional Interface (Module KML.5)
- Standard DDS CSU/DSU (Module KML.6)
- T1 Link Interface (Module KML.7)
- E1 Link Interface (Module KML.8)
- ISDN "S" Interface (Module KML.10/S)
- ISDN "U" Interface (Module KML.10/U)
- Fiber-Optic Link Interface (Module KML.F)
- I/O Module Applications
- Technical System Characteristics
- Chapter 2 Installation
- Introduction
- Site Requirements and Prerequisites
- Input Power Requirements
- Grounding
- Channel Connection Considerations
- Front and Rear Panel Clearance
- Ambient Requirements
- Electromagnetic Compatibility Considerations
- Current and Power Requirements of MX-2100 Power Supply Modules
- Current and Power Capabilities of MX-2100 Power Supply Modules
- Ratings of Ring and Feed Voltage Supplies
- Equipment Needed
- Package Contents
- Installation and Setup of MX-2100
- Interfaces and Connections
- Initial Setup and Configuration
- Chapter 3 Configuring MX-2100
- Chapter 4 Operation
- Chapter 5 Diagnostics
- Appendix A Connection Data
- Appendix B Alarms
- Appendix C SNMP Management
- Appendix D Software Download
- Appendix E Configuration Parameters
- Appendix F Command Set Description
- General
- Commands
- BYE
- CLR ALM
- CLR LOOP
- CLR MONITOR
- CONNECT SWITCH
- DATE
- DEF AGENDA
- DEF AGENT
- DEF ALM DEBOUNCE
- DEF CALL
- DEF CH
- DEF CON
- DEF DB FLIP
- DEF DP
- DEF FRAME
- DEF MANAGER LIST
- DEF ML
- DEF ML CALL
- DEF NAME
- DEF NODE
- DEF NP
- DEF PWD
- DEF ROUTE
- DEF SP
- DEF SYS
- DISCONNECT SWITCH
- DSP AGENT
- DSP ALM
- DSP BERT
- DSP CH CON
- DSP FLIP
- DSP HDR TST
- DSP MANAGER LIST
- DSP KVF5orDSP PBX
- DSP KVF6
- DSP SIGNALINGorDSP SIG
- DSP PRBS_INJ
- DSP REM AGENT
- DSP REV
- DSP ST FRAME
- DSP ST ML
- DSP ST SLOT
- DSP ST SYS
- EDIT DB
- EXIT
- F
- FLIP ML
- HELP
- INIT DB
- INIT F
- LOAD DB 1\2
- LOAD IO
- LOOP
- ML RECOVERY
- MONITOR
- REBUILD FRAME
- RESET LOC
- RESET IO
- RESET ML
- TIME
- UPDATE DB 1\2
- Index
- DC Power Supply Connection

MX-2100/2104 Installation and Operation Manual Chapter 4 Operation
MX-2100 Supervision Language 4-3
Command Protocol
Starting a Session
• If AUTOBAUD is on, start any session by pressing the ENTER key three times
in sequence. This will ensure identification of terminal data rate.
• When password protection is on, the displayed prompt is PASSWORD> and
the addressed MX-2100 waits for the password before continuing. After the
correct password is received, MX-2100 sends the following working prompt:
KM2100> for MX-2100
KM2104> for MX-2104.
If password protection is off, this step is omitted and the working prompt
appears after the node address conditions are fulfilled.
• The first action to be carried out when starting a session is to check and, if
necessary, set the correct terminal control codes, using the F command.
The terminal control codes, determined by the F command, are used to clear the
screen, move the cursor to the screen home position, and move the cursor to the
right by one position. Using the terminal control codes suitable for the type of
terminal connected to MX-2100 is essential to proper display of the information
sent by MX-2100 on the terminal screen: certain combinations of codes can lead
to unclear displays.
If the information on your screen is unclear, issue the INIT F [] command. If
there are no parameters, use the F
command to set the desired control codes.
Command Evaluation and Execution
• After the working prompt is displayed, every character typed on the terminal
keyboard is immediately evaluated by MX-2100 and echoed to the terminal
screen. Full duplex communication with the terminal is therefore necessary, to
provide on-line feedback to the terminal operator.
• Command evaluation starts only when the ENTER key is pressed.
• Certain commands, mainly DSP commands, are not accepted for the alternate
database.
• In case an error is detected during command evaluation, the command is not
executed. Instead, MX-2100 will send the erroneous command back to the
terminal, and you will see:
BAD COMMAND OR PARAMETER. TYPE ‘H’ FOR HELP
• The correct command must then be resent.
• The command is executed only after it is validated.
• Command execution can be interrupted by pressing BREAK or CTRL-C. This
will result in the display of the MX-2100 prompt, and a new command can be
entered.