Operating instructions
TM 55-4920-394-13&P
Table 1-1. Leading Particular
HYDRAULIC SYSTEMS
Fluid Reservoir
Capacity (@ incline of 8 ½ degrees) ................................................ 25 Useable U.S. Gallons
Material ........................................................................................... Aluminum
Hydraulic Fluid......................................................................................... MIL-H-5606 or MIL-H-82382
Hydraulic Pumps
Type ................................................................................................ High pressure, axial
piston, variable stroke,
pressure compensated with
integral low pressure
boost section
Capacity .......................................................................................... 0-27 gpm up to 3000 psig;
0-15 gpm up to 5000 psig
Discharge pressure.......................................................................... 2700 + 50 psig when de-
livering 30 gpm with zero
flow pressure setting at
3000 psig
Pressure compensator ..................................................................... Adjustable at control
panel from 500 to 5000
psig
Boost pump capacity........................................................................ 33 gpm at 150 psi
Fill Pump
Type ................................................................................................ Motor driven internal
gear
Capacity .......................................................................................... 2 gpm at 150 psig
High Pressure Filter
Rating.............................................................................................. 30 gpm at 5000 psig
Size of element................................................................................ 5 micron
Specification.................................................................................... MIL-F-27656
Low Pressure Filter
Element........................................................................................... 10 micron, two element/
filter AN6236-3
Oil Cooler
Type ................................................................................................ Air-to-oil, fan cooled,
Electric Motor Driven
1-3