Operating Instructions and Installation Instructions

v
H
H
S
H
S
P
45°
H
P
P
H
r
23
15-ALARMS
Technical Dept. - All rights reserved - Reproduction is prohibited
Changing the position of the pressure switch
ATTENTION!
All the operations must be performed with the product completely cold and the plug disconnected. Disconnect the
product from the 230V power supply before performing any operation.
One can then act on the air pressure switch by changing the installation position. The pressure switch is tted behind the electronic board
of the stove.
To change the position of the pressure switch, which by default is in
an upright position, proceed as described below:
remove the side covering of the stove
remove the back panel of the stove
unscrew the two screws “v” and remove the entire block “H”
consisting of a board support, board and pressure switch
remove board “S” from the support
remove screws r that block the pressure switch “P in a vertical
position
Tilt the pressure switch by 45° and use the designated holes to
secure it with screws “r”
reassemble everything
PLEASE NOTE There are two small tubes coming out of the pressure switch, one connected to the pressure transducer and
the other one to the tank. For the shift there is no need to remove this connection, also to avoid reassembly errors.
There might be the need to disconnect some cables when disconnecting the electronic board.
Attention! All the adjustments must be performed solely by authorised and qualied personnel.