Unit Electrical Data Table
Table 6: Unit Electrical Data
Unit Size
Power Compressor
Motor FLA
Total Unit
FLA
Min. Volts
Min. Circuit
Ampacity
Max. Fuse
Size
Volt Hz Phase RLA LRA
009
115 60 1 8.0 50 0.63 8.63 104 10.6 15
208/230 60 1 3.7 22 0.40 4.10 197 5.0 15
265 60 1 3.5 22 0.35 3.85 240 4.7 15
012
115 60 1 9.5 50 1.60 11.10 104 13.5 20
208/230 60 1 4.7 25 0.60 5.30 197 6.5 15
015
208/230 60 1 5.6 29 0.82 6.42 197 7.8 15
265 60 1 5.0 28 0.55 5.55 240 6.8 15
019 208/230 60 1 7.4 33 0.82 8.22 197 10.1 15
Units with Boilerless System Electric Heat
Table 7: Units with Boilerless System Electric Heat
Unit
Size
Power Electric Heater Compressor
Motor FLA
Total Unit
FLA
Min. Volts
Min. Circuit
Ampacity
Max. Fuse
Size
Volt/Hz/Phase
kW
Amps RLA LRA
Nominal Actual
009
208/60/1
1.0
0.62 3.0 3.7 22 0.40 4.10 197 5.0 15
230/60/1 0.75 3.3 3.7 22 0.40 4.10 197 5.0 15
265/60/1 1.00 3.8 3.5 22 0.35 3.85 240 5.2 15
208/60/1
2.0
1.23 5.9 3.7 22.0 0.40 4.10 197 5.0 15
230/60/1 1.5 6.5 3.7 22.0 0.40 4.10 197 5.0 15
265/60/1 2.0 7.5 3.5 22.0 0.35 3.85 240 5.2 15
012
208/60/1
1.0
0.62 3.0 4.7 25 0.60 5.30 197 6.5 15
230/60/1 0.75 3.3 4.7 25 0.60 5.30 197 6.5 15
208/60/1
2.0
1.23 5.9 4.7 25.0 0.60 5.30 197 6.5 15
230/60/1 1.5 6.5 4.7 25.0 0.60 5.30 197 6.5 15
015
208/60/1
2.0
1.23 5.9 5.6 29 0.82 6.42 197 8.4 15
230/60/1 1.50 6.5 5.6 29 0.82 6.42 197 9.9 15
265/60/1 2.00 7.5 5.0 28 0.55 5.55 240 10.1 15
019
208/60/1
2.0
1.23 5.9 7.4 33 0.82 8.22 197 10.1 15
230/60/1 1.50 6.5 7.4 33 0.82 8.22 197 10.1 15