Specifications

73
General Data - Heat pump (R407C)
General Data - Heat pump (R407C)
Btu/h 149000 190000
W 43670 55680
Btu/h 160000 230000
W 46890 67410
W 16570 21160
W 15710 20300
A 32.2 39.9
A 31.2 38.4
V/Ph/Hz
W/W 2.75 2.63
W/W 3.12 3.32
AIR DISCHARGE
OPERATION
AIR FLOW l/s / cfm 2667 / 5651 3167 / 6710
EXTERNAL STATIC PRESSURE Pa/in.wg.
mm/in
l/s / cfm
dBA
mm/in
mm/in
mm/in
mm/in
mm/in
mm/in
kg/lb 700 / 1543 800 / 1764
kg/lb 2 x 5.0 / 2 x 11.02 x 5.8 / 2 x 12.8
1938 / 76.3
25.4 / 1
1200 / 47.2
1800 / 70.9
1320 / 52.0
1990 / 78.4
2100 / 82.7
5333 / 11300
70
M4RT150AR M4RT200AR
380 ~ 415 / 3 / 50
196 / 0.79
DUCTED
SEQUENTIAL CONTROLLER
R407C / TXV
NOMINAL RUNNING CURRENT (HEATING)
POWER SOURCE
REFRIGERANT TYPE / CONTROL
EER
COP
MODEL
CONTROL
EVAPORATOR*
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
NOMINAL TOTAL INPUT POWER (COOLING)
NOMINAL TOTAL INPUT POWER (HEATING)
NOMINAL RUNNING CURRENT (COOLING)
CONDENSATE DRAIN SIZE
UNIT DIMENSION
SOUND PRESSURE LEVEL
CONDENSER*
PACKING DIMENSION
HEIGHT
WIDTH
DEPTH
HEIGHT
WIDTH
REFRIGERANT CHARGE
AIR FLOW
DEPTH
UNIT WEIGHT
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 13253.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.
5) * DESIGNATION BASED ON COOLING CYCLE.
6) EFFECTIVE POWER INPUT IS USED IN THE RATED EER/COP CALCULATION, ACCORDING TO ISO STANDARD: ISO 13253
Btu/h 230000 283000
W 67410 82940
Btu/h 255000 315000
W 74730 92320
W 29200 38160
W 26220 34780
A 52.1 65.5
A 48.6 61.9
V/Ph/Hz
W/W 2.30 2.07
W/W 2.73 2.55
AIR DISCHARGE
OPERATION
AIR FLOWl/s / cfm 3776 / 8000 4389 / 9300
EXTERNAL STATIC PRESSURE Pa/in.wg.
mm/in
l/s / cfm
dBA
mm/in
mm/in
mm/in
mm/in
mm/in
mm/in
kg/lb 1200 / 2646 1350 / 2976
kg/lb 2 x 9.4 / 2 x 20.72 x 9.6 / 2 x 21.2
REFRIGERANT CHARGE
AIR FLOW
DEPTH
UNIT WEIGHT
CONDENSATE DRAIN SIZE
UNIT DIMENSION
SOUND PRESSURE LEVEL
CONDENSER*
PACKING DIMENSION
HEIGHT
WIDTH
DEPTH
HEIGHT
WIDTH
MODEL
CONTROL
EVAPORATOR*
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
NOMINAL TOTAL INPUT POWER (COOLING)
NOMINAL TOTAL INPUT POWER (HEATING)
NOMINAL RUNNING CURRENT (COOLING)
NOMINAL RUNNING CURRENT (HEATING)
POWER SOURCE
REFRIGERANT TYPE / CONTROL
EER
COP
M4RT250AR M4RT300AR
380 ~ 415 / 3 / 50
294 / 1.18
DUCTED
SEQUENTIAL CONTROLLER
R407C / TXV
2900 / 114
25.4 / 1
1735 / 68.0
2800 / 110.0
1900 / 75
2250 / 88.5
2250 / 88.5
9439 / 20000
74
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 13253.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.
5) * DESIGNATION BASED ON COOLING CYCLE.
6) EFFECTIVE POWER INPUT IS USED IN THE RATED EER/COP CALCULATION, ACCORDING TO ISO STANDARD: ISO 13253.