Specifications
72
General Data - Heat pump (R407C)
General Data - Heat pump (R407C)
Btu/h 56000 72000
W 16710 21100
Btu/h 69000 77000
W 20220 22570
W 6650 8410
W 6580 7540
A 13.2 16.0
A 12.9 15.4
V/Ph/Hz
W/W 2.47 2.40
W/W 3.07 2.85
AIR DISCHARGE
OPERATION
AIR FLOW l/s / cfm 850 / 1800 1334 / 2826
EXTERNAL STATIC PRESSURE Pa/in.wg.
mm/in
l/s / cfm 2124 / 4500 2667 / 5650
dBA 63 65
mm/in
mm/in 1100 / 43.3
1300 / 51.2
mm/in
mm/in
mm/in
1250 / 49.2
1450 / 57.1
mm/in
kg/lb
320 / 705
385 / 849
kg/lb
4.3 / 9.5
5.2 / 11.5
1680 / 66.1
25.4 / 1
1000 / 39.4
1530 / 60.2
1090 / 42.9
M4RT060AR M4RT080AR
380 ~ 415 / 3 / 50
98 / 0.39
DUCTED
SLM CONTROLLER
R407C / TXV
NOMINAL RUNNING CURRENT (HEATING)
POWER SOURCE
REFRIGERANT TYPE / CONTROL
EER
COP
MODEL
CONTROL
EVAPORATOR*
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
NOMINAL TOTAL INPUT POWER (COOLING)
NOMINAL TOTAL INPUT POWER (HEATING)
NOMINAL RUNNING CURRENT (COOLING)
CONDENSATE DRAIN SIZE
UNIT DIMENSION
SOUND PRESSURE LEVEL
CONDENSER*
PACKING DIMENSION
HEIGHT
WIDTH
DEPTH
HEIGHT
WIDTH
REFRIGERANT CHARGE
AIR FLOW
DEPTH
UNIT WEIGHT
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 13253.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.
5) * DESIGNATION BASED ON COOLING CYCLE.
6) EFFECTIVE POWER INPUT IS USED IN THE RATED EER/COP CALCULATION, ACCORDING TO ISO STANDARD: ISO 13253
Btu/h 88000 100000
W 25790 29310
Btu/h 102000 122000
W 29890
35760
W 10820 12810
W 9810 11260
A 20.6 23.2
A 19.3 21.2
V/Ph/Hz
W/W 2.26 2.29
W/W 2.92 3.17
AIR DISCHARGE
OPERATION
AIR FLOW l/s / cfm 1667 / 3532 1699 / 3600
EXTERNAL STATIC PRESSURE Pa/in.wg.
mm/in
l/s / cfm
2667 / 5650
4719 / 10000
dBA
66 68
mm/in
mm/in
mm/in
mm/in
mm/in
mm/in
kg/lb
415 / 915 440 / 970
kg/lb
6.0 / 13.26.0 / 13.2
1680 / 66.1
25.4 / 1
UNIT WEIGHT
CONDENSATE DRAIN SIZE
UNIT DIMENSION
SOUND PRESSURE LEVEL
1450 / 57.1
1000 / 39.4
1530 / 60.2
1090 / 42.9
CONDENSER*
PACKING DIMENSION
HEIGHT
WIDTH
DEPTH
HEIGHT
WIDTH
REFRIGERANT CHARGE
AIR FLOW
DEPTH
MODEL
CONTROL
EVAPORATOR*
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
NOMINAL TOTAL INPUT POWER (COOLING)
NOMINAL TOTAL INPUT POWER (HEATING)
NOMINAL RUNNING CURRENT (COOLING)
NOMINAL RUNNING CURRENT (HEATING)
POWER SOURCE
REFRIGERANT TYPE / CONTROL
EER
COP
1300 / 51.2
M4RT100AR M4RT120AR
380 ~ 415 / 3 / 50
98 / 0.39
DUCTED
SLM CONTROLLER
R407C / TXV
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 13253.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.
5) * DESIGNATION BASED ON COOLING CYCLE.
6) EFFECTIVE POWER INPUT IS USED IN THE RATED EER/COP CALCULATION, ACCORDING TO ISO STANDARD: ISO 13253.