Specifications

69
General Data - Cooling Only (R407C)
General Data - Cooling Only (R407C)
Btu/h 59000 72000
W 17290 21100
W 5890 8700
A 10.9 16.3
V/Ph/Hz
R407C / TXV R407C / CAPILLARY TUBE
W/W 2.94 2.32
AIR DISCHARGE
OPERATION
AIR FLOWl/s / cfm 850 / 1800 1334 / 2826
EXTERNAL STATIC PRESSURE Pa/in.wg.
mm/in
l/s / cfm 2124 / 4500 2667 / 5650
dBA 63 65
mm/in
mm/in 1100 / 43.3 1300 / 51.2
mm/in
mm/in
mm/in
1250 / 49.2
1450 / 57.1
mm/in
kg/lb 295 / 650 370 / 816
kg/lb 4.6 / 10.14.6 / 10.1
EER
DEPTH
UNIT WEIGHT
98 / 0.39
SLM CONTROLLER
1680 / 66.1
HEIGHT
SOUND PRESSURE LEVEL
NOMINAL TOTAL INPUT POWER
NOMINAL RUNNING CURRENT
AIR FLOW
CONDENSER
WIDTH
REFRIGERANT CHARGE
POWER SOURCE
REFRIGERANT TYPE / CONTROL
NOMINAL CAPACITY
1530 / 60.2
1090 / 42.9
UNIT DIMENSION
1000 / 39.4
PACKING DIMENSION
HEIGHT
WIDTH
DEPTH
M4RT060AMODEL
EVAPORATOR
DUCTED
CONDENSATE DRAIN SIZE
M4RT080A
380 ~ 415 / 3 / 50
CONTROL
25.4 / 1
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 13253.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.
5) EFFECTIVE POWER INPUT IS USED IN THE RATED EER/COP CALCULATION, ACCORDING TO ISO STANDARD: ISO 13253.
Btu/h 95000 110000
W 27840 32240
W 11600 12180
A 20.2 22.8
V/Ph/Hz
R407C / CAPILLARY TUBE R407C / TXV
W/W 2.31 2.65
AIR DISCHARGE
OPERATION
AIR FLOW l/s / cfm 1667 / 3532 1699 / 3600
EXTERNAL STATIC PRESSURE Pa/in.wg.
mm/in
l/s / cfm 2667 / 5650 3776 / 8000
dBA 66 68
mm/in
mm/in
mm/in
mm/in
mm/in
mm/in
kg/lb 400 / 882 425 / 937
kg/lb 5.9 / 135.6 / 12.3
NOMINAL CAPACITY
98 / 0.39
SLM CONTROLLER
EVAPORATOR
DUCTED
CONDENSATE DRAIN SIZE
REFRIGERANT TYPE / CONTROL
EER
1680 / 66.1
M4RT120A
380 ~ 415 / 3 / 50
1000 / 39.4
1300 / 51.2
1450 / 57.1
25.4 / 1
M4RT100A
1530 / 60.2
1090 / 42.9
CONDENSER
PACKING DIMENSION
HEIGHT
WIDTH
DEPTH
HEIGHT
WIDTH
REFRIGERANT CHARGE
DEPTH
UNIT WEIGHT
MODEL
UNIT DIMENSION
SOUND PRESSURE LEVEL
NOMINAL TOTAL INPUT POWER
NOMINAL RUNNING CURRENT
CONTROL
AIR FLOW
POWER SOURCE
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 13253.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.
5) EFFECTIVE POWER INPUT IS USED IN THE RATED EER/COP CALCULATION, ACCORDING TO ISO STANDARD: ISO 13253.