Specifications
67
General Data - Heat pump (R22)
General Data - Heat pump (R22)
Btu/h 100000 105000
W 29300
30770
Btu/h
105000 118000
W 30800
32580
W 11860 11600
W 10050 10700
A 20.5 21.6
A 18.2 21.0
V/Ph/Hz
R22 / CAPILLARY TUBE R22 / TXV
W/W 2.03 2.65
W/W 2.67 3.23
AIR DISCHARGE
OPERATION
AIR FLOW l/s / cfm 1667 / 3532 1699 / 3600
EXTERNAL STATIC PRESSURE Pa/in.wg.
mm/in
l/s / cfm 2667 / 5650 4719 / 10000
dBA 66 68
mm/in
mm/in
mm/in
mm/in
mm/in
mm/in
kg/lb 415 / 915 440 / 970
kg/lb 5.6 / 12.36.0 / 13.2
REFRIGERANT CHARGE
AIR FLOW
DEPTH
UNIT WEIGHT
CONDENSATE DRAIN SIZE
UNIT DIMENSION
SOUND PRESSURE LEVEL
CONDENSER*
PACKING DIMENSION
HEIGHT
WIDTH
DEPTH
HEIGHT
WIDTH
MODEL
CONTROL
EVAPORATOR*
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
NOMINAL TOTAL INPUT POWER (COOLING)
NOMINAL TOTAL INPUT POWER (HEATING)
NOMINAL RUNNING CURRENT (COOLING)
NOMINAL RUNNING CURRENT (HEATING)
POWER SOURCE
REFRIGERANT TYPE / CONTROL
EER
COP
MRT100AR MRT120AR
380 ~ 415 / 3 / 50
98 / 0.39
DUCTED
SLM CONTROLLER
1680 / 66.1
25.4 / 1
1000 / 39.4
1530 / 60.2
1090 / 42.9
1300 / 51.2
1450 / 57.1
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 13253.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.
5) * DESIGNATION BASED ON COOLING CYCLE.
6) EFFECTIVE POWER INPUT IS USED IN THE RATED EER/COP CALCULATION, ACCORDING TO ISO STANDARD: ISO 13253
Btu/h
150000 200000
W 44000
58600
Btu/h 155000 208000
W 45400 61000
W 18600 23500
W 15400 20400
A 33.0 39.2
A 29.0 35.0
V/Ph/Hz
W/W 2.26 2.19
W/W 3.02 2.80
AIR DISCHARGE
OPERATION
AIR FLOWl/s / cfm 2667 / 5651 3167 / 6710
EXTERNAL STATIC PRESSURE Pa/in.wg.
mm/in
l/s / cfm
dBA
mm/in
mm/in
mm/in
mm/in
mm/in
mm/in
kg/lb
700 / 1543
800 / 1764
kg/lb
2 x 4.7 / 2 x 10.4
2 x 5.6 / 2 x 12.3
1938 / 76.3
25.4 / 1
1200 / 47.2
1800 / 70.9
1320 / 52.0
1990 / 78.4
2100 / 82.7
5333 / 11300
70
MRT150AR MRT200AR
380 ~ 415 / 3 / 50
196 / 0.79
DUCTED
SEQUENTIAL CONTROLLER
R22 / CAPILLARY TUBE
NOMINAL RUNNING CURRENT (HEATING)
POWER SOURCE
REFRIGERANT TYPE / CONTROL
EER
COP
MODEL
CONTROL
EVAPORATOR*
NOMINAL COOLING CAPACITY
NOMINAL HEATING CAPACITY
NOMINAL TOTAL INPUT POWER (COOLING)
NOMINAL TOTAL INPUT POWER (HEATING)
NOMINAL RUNNING CURRENT (COOLING)
CONDENSATE DRAIN SIZE
UNIT DIMENSION
SOUND PRESSURE LEVEL
CONDENSER*
PACKING DIMENSION
HEIGHT
WIDTH
DEPTH
HEIGHT
WIDTH
REFRIGERANT CHARGE
AIR FLOW
DEPTH
UNIT WEIGHT
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 13253.
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW :
a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR
b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR
4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.
5) * DESIGNATION BASED ON COOLING CYCLE.
6) EFFECTIVE POWER INPUT IS USED IN THE RATED EER/COP CALCULATION, ACCORDING TO ISO STANDARD: ISO 13253